摘要 In this study, a finite element simulation of in-stent restenosis (ISR) is conducted to simulate the deployment and expansion of a stent in an occluded artery with a contact model and a mechanics-based growth model. A tissue growth model based on the multiplicative decomposition of deformation is applied to investigate the growth of the plaque and artery wall upon the stent’s implantation. Due to the high stresses at the contact points between the stent struts and the tissue, further tissue injury or restenosis is observed. The simulation results show that after the stent deployment, the von Mises stress is significantly larger in the plaque compared to the artery wall, especially in the region that is in contact with the stent. However, the growth of the plaque and artery tends to even out the stress concentration over time. The tissue growth is found to be more significant near the inner wall than the outer layer. A 0.77 mm restenosis is predicted, which agrees with published clinical observations. The features of the artery growth are carefully analyzed, and the underlying mechanism is discussed. This study is the first attempt to apply finite element analysis to artery restenosis, which establishes a framework for predicting ISR’s occurrence and severity. The results also provide insights into understanding the underlying mechanism of in-stent restenosis. In this study, a finite element simulation of in-stent restenosis (ISR) is conducted to simulate the deployment and expansion of a stent in an occluded artery with a contact model and a mechanics-based growth model. A tissue growth model based on the multiplicative decomposition of deformation is applied to investigate the growth of the plaque and artery wall upon the stent’s implantation. Due to the high stresses at the contact points between the stent struts and the tissue, further tissue injury or restenosis is observed. The simulation results show that after the stent deployment, the von Mises stress is significantly larger in the plaque compared to the artery wall, especially in the region that is in contact with the stent. However, the growth of the plaque and artery tends to even out the stress concentration over time. The tissue growth is found to be more significant near the inner wall than the outer layer. A 0.77 mm restenosis is predicted, which agrees with published clinical observations. The features of the artery growth are carefully analyzed, and the underlying mechanism is discussed. This study is the first attempt to apply finite element analysis to artery restenosis, which establishes a framework for predicting ISR’s occurrence and severity. The results also provide insights into understanding the underlying mechanism of in-stent restenosis.
作者 Jie Cheng Lucy T. Zhang Jie Cheng;Lucy T. Zhang(Department of Mechanical, Aerospace and Nuclear Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA)
出处 《Journal of Biomedical Science and Engineering》 2021年第2期33-47,共15页 生物医学工程(英文)
关键词 STENTS In-Stent Restenosis Tissue Growth Finite Element Simulation Growth Model Stents In-Stent Restenosis Tissue Growth Finite Element Simulation Growth Model
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部