期刊文献+

Estimation of Fatigue Strength of Reinforced Complete Upper Denture Using a Newly Designed Testing Machine: A Laboratory Research Project

Estimation of Fatigue Strength of Reinforced Complete Upper Denture Using a Newly Designed Testing Machine: A Laboratory Research Project
下载PDF
导出
摘要 In the present study, an aero pneumatic fatigue testing machine for complete dentures was designed, fabricated, and tested for the evaluation of the fatigue life of reinforced complete upper denture (CUD). On completion and testing, it was observed that the machine has the potential of generating reliable number of cyclic data. The machine’s performance was evaluated using test specimens of identical CUDs that were machined in conformity with standard procedures. The fatigue machine compressed the lower dental arch over the upper denture-specimen in centric occlusion, in the same way that the two masticatory muscles pull the lower jaw over the upper jaw during chewing. The incorporation of glass fibres into the CUD using a sandwich technique quadruples the lifespan of the denture (<em>P</em> = 0.004). The low standard deviation, along with the low coefficient of variation (CV) of the group of unreinforced dentures shows the repeatability of the results and the reliability of the machine. The high standard deviation and coefficient of variation of reinforced dentures was expected, since a high variation of results is usually recorded in fibre reinforcement cases. This research confirmed the view that the crack during denture fracture initiates in the anterior palatal area and propagates to the posterior. In the present study, an aero pneumatic fatigue testing machine for complete dentures was designed, fabricated, and tested for the evaluation of the fatigue life of reinforced complete upper denture (CUD). On completion and testing, it was observed that the machine has the potential of generating reliable number of cyclic data. The machine’s performance was evaluated using test specimens of identical CUDs that were machined in conformity with standard procedures. The fatigue machine compressed the lower dental arch over the upper denture-specimen in centric occlusion, in the same way that the two masticatory muscles pull the lower jaw over the upper jaw during chewing. The incorporation of glass fibres into the CUD using a sandwich technique quadruples the lifespan of the denture (<em>P</em> = 0.004). The low standard deviation, along with the low coefficient of variation (CV) of the group of unreinforced dentures shows the repeatability of the results and the reliability of the machine. The high standard deviation and coefficient of variation of reinforced dentures was expected, since a high variation of results is usually recorded in fibre reinforcement cases. This research confirmed the view that the crack during denture fracture initiates in the anterior palatal area and propagates to the posterior.
作者 Anthony E. Prombonas Nikolas A. Poulis Evangelos A. Prombonas Anthony E. Prombonas;Nikolas A. Poulis;Evangelos A. Prombonas(Division of Dental Technology, Department of Biomedical Sciences, School of Health and Care Sciences, University of West Attica, Athens, Greece;Centre for Dental Sciences, Faculty of Health and Wellbeing, University of Bolton, Manchester, UK;Master in Information Technology, University of Limoge, Limoges, France)
出处 《Journal of Biomedical Science and Engineering》 2021年第2期48-63,共16页 生物医学工程(英文)
关键词 Fatigue Testing Machine Complete Upper Denture Crack Initiation Crack Propagation Fatigue Fracture Fatigue Testing Machine Complete Upper Denture Crack Initiation Crack Propagation Fatigue Fracture
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部