期刊文献+

Influence of Phosphoric Acid Etching on the Bond Strength of a Universal Adhesive System to Caries-Affected Dentin 被引量:1

Influence of Phosphoric Acid Etching on the Bond Strength of a Universal Adhesive System to Caries-Affected Dentin
下载PDF
导出
摘要 The purpose of this study was to evaluate the influence of acid etching on the bond strength of a universal adhesive system (Single Bond Universal, 3M) to caries-affected dentin. Forty permanent third molars were selected and carious lesions were induced by the microbiological method with?S. mutans?ATCC25175. Teeth were allocated randomly across four experimental designs (n?=?10): PA-I: phosphoric acid etching and application of the adhesive system, followed by immediate microtensile bond strength testing;PA-CC: phosphoric acid etching and application of the adhesive system, followed by microtensile bond strength testing after a 14-day cariogenic challenge;NPA-I: application of the adhesive system without acid etching, followed by immediate bond strength testing and NPA-CC: application of the adhesive system without acid etching followed by bond strength testing after 14-day cariogenic challenge. For microtensile bond strength testing,?a restoration with Charisma composite resin was made and each specimen was sectioned with a cross-sectional area of 1 mm2. Only adhesive and mixed fractures were considered for bond strength calculation. Results were evaluated by the Kruskal-Wallis and Friedman tests. The highest bond strengths were observed in the phosphoric acid etching groups (p??0.05). Cariogenic challenge did not affect bond strength (p?>?0.05). The predominant fracture type was adhesive. We conclude that phosphoric acid increased the bond strength of the Single Bond Universal system to caries-affected dentin, and that cariogenic challenge did not interfere with this bond strength. The purpose of this study was to evaluate the influence of acid etching on the bond strength of a universal adhesive system (Single Bond Universal, 3M) to caries-affected dentin. Forty permanent third molars were selected and carious lesions were induced by the microbiological method with?S. mutans?ATCC25175. Teeth were allocated randomly across four experimental designs (n?=?10): PA-I: phosphoric acid etching and application of the adhesive system, followed by immediate microtensile bond strength testing;PA-CC: phosphoric acid etching and application of the adhesive system, followed by microtensile bond strength testing after a 14-day cariogenic challenge;NPA-I: application of the adhesive system without acid etching, followed by immediate bond strength testing and NPA-CC: application of the adhesive system without acid etching followed by bond strength testing after 14-day cariogenic challenge. For microtensile bond strength testing,?a restoration with Charisma composite resin was made and each specimen was sectioned with a cross-sectional area of 1 mm2. Only adhesive and mixed fractures were considered for bond strength calculation. Results were evaluated by the Kruskal-Wallis and Friedman tests. The highest bond strengths were observed in the phosphoric acid etching groups (p??0.05). Cariogenic challenge did not affect bond strength (p?>?0.05). The predominant fracture type was adhesive. We conclude that phosphoric acid increased the bond strength of the Single Bond Universal system to caries-affected dentin, and that cariogenic challenge did not interfere with this bond strength.
出处 《Advances in Biological Chemistry》 2018年第3期37-46,共10页 生物化学进展(英文)
关键词 Caries-Affected DENTIN UNIVERSAL Adhesives Hybrid Layer Collagen Fibers MICROTENSILE Bond Strength Caries-Affected Dentin Universal Adhesives Hybrid Layer Collagen Fibers Microtensile Bond Strength
  • 相关文献

同被引文献1

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部