Dielectric Analysis of Response Time in Electrorheological Fluids Developed for Medical Devices

Dielectric Analysis of Response Time in Electrorheological Fluids Developed for Medical Devices
下载PDF
导出
摘要 Three electrorheological fluids (ERFs) of recently synthesized Polyaniline.HCl and Cellulose fluids as well as a commercial product from Fludicon? (Germany), were evaluated with a two-electrode probe unit and by Dielectric Analysis (DEA). The study was a part of an ongoing medical device development project. The dielectric response times were calculated using the critical peak frequency in a corresponding Debye plot of Tan Delta (loss factor/permittivity) vs. log frequency. The DEA revealed the response times (tau, τ) in ms. The Fludicon? ERF was DEA durable (repeat cycles produced same results) and the τ was temperature dependent: 16 ms at 25°C and 0.16 ms at 80°C. The Cellulose ERF was somewhat DEA durable and the τ was 5.5 ms at 25°C and 0.21 ms at 80°C. The response times were logarithmic with the temperature (°C) with a correlation coefficient of >0.98 for the Cellulose and Fludicon? ERFs. The Polyaniline ERF had a τ of 53 ms at 25°C in the 1st DEA run and there was no indication of a τ for the remaining DEA tests. Three electrorheological fluids (ERFs) of recently synthesized Polyaniline.HCl and Cellulose fluids as well as a commercial product from Fludicon? (Germany), were evaluated with a two-electrode probe unit and by Dielectric Analysis (DEA). The study was a part of an ongoing medical device development project. The dielectric response times were calculated using the critical peak frequency in a corresponding Debye plot of Tan Delta (loss factor/permittivity) vs. log frequency. The DEA revealed the response times (tau, τ) in ms. The Fludicon? ERF was DEA durable (repeat cycles produced same results) and the τ was temperature dependent: 16 ms at 25°C and 0.16 ms at 80°C. The Cellulose ERF was somewhat DEA durable and the τ was 5.5 ms at 25°C and 0.21 ms at 80°C. The response times were logarithmic with the temperature (°C) with a correlation coefficient of >0.98 for the Cellulose and Fludicon? ERFs. The Polyaniline ERF had a τ of 53 ms at 25°C in the 1st DEA run and there was no indication of a τ for the remaining DEA tests.
机构地区 不详
出处 《American Journal of Analytical Chemistry》 2011年第2期85-92,共8页 美国分析化学(英文)
关键词 ERF TAN Delta DEA FIBRILLATION DEBYE PLOT Response Time ERF Tan Delta DEA Fibrillation Debye Plot Response Time
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部