摘要 Surfactant enhanced chemofiltration on Nylon membranes pre-treated with hexadecyltrimethylammonium bromide (HTAB) and eosin dye (eo) is proposed for zinc traces quantification by solid surphase spectro- fluorimetry (SSF, λexc = 532 nm;λem = 548 nm). Operational variables which have influence on quantitative retention of metal complex have been studied and optimized. At optimal experimental conditions, quantita- tive recovery was reached with a detection limit of 0.662 pg?L–1 and quantification limit of 2.20 pg?L–1. The calibration sensitivity was of 1.22 L?pg–1 for the new methodology with a linear range of 2.20 pg?L–1 to 779 pg?L–1 Zn (II). The tolerance levels of potential interfering ions were studied with good results. Recuperation studies were carried out by standard addition method applied to natural water samples (San Juan, Argentine) without previous treatment. The reproducibility (between-days precision) was also evaluated over 3 days by performing five determinations each day. CV% was 0.37. The performing obtained in sensitivity and selec- tivity thanks to chemofiltration step, converts the proposed methodology in an adequate alternative to con- ventional techniques for Zn (II) traces determination. Surfactant enhanced chemofiltration on Nylon membranes pre-treated with hexadecyltrimethylammonium bromide (HTAB) and eosin dye (eo) is proposed for zinc traces quantification by solid surphase spectro- fluorimetry (SSF, λexc = 532 nm;λem = 548 nm). Operational variables which have influence on quantitative retention of metal complex have been studied and optimized. At optimal experimental conditions, quantita- tive recovery was reached with a detection limit of 0.662 pg?L–1 and quantification limit of 2.20 pg?L–1. The calibration sensitivity was of 1.22 L?pg–1 for the new methodology with a linear range of 2.20 pg?L–1 to 779 pg?L–1 Zn (II). The tolerance levels of potential interfering ions were studied with good results. Recuperation studies were carried out by standard addition method applied to natural water samples (San Juan, Argentine) without previous treatment. The reproducibility (between-days precision) was also evaluated over 3 days by performing five determinations each day. CV% was 0.37. The performing obtained in sensitivity and selec- tivity thanks to chemofiltration step, converts the proposed methodology in an adequate alternative to con- ventional techniques for Zn (II) traces determination.
机构地区 不详
出处 《American Journal of Analytical Chemistry》 2011年第8期902-908,共7页 美国分析化学(英文)
关键词 ZINC TRACES Eosin Dye SURFACTANT ENHANCED Chemofiltration SOLID Surphase FLUORESCENCE Natural Water Samples Zinc Traces Eosin Dye Surfactant Enhanced Chemofiltration Solid Surphase Fluorescence Natural Water Samples
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部