Near-Infrared Spectroscopic Analysis of Hemoglobin with Stability Based on Human Hemolysates Samples

Near-Infrared Spectroscopic Analysis of Hemoglobin with Stability Based on Human Hemolysates Samples
下载PDF
导出
摘要 Near-infrared (NIR) spectroscopy combined with the partial least-squares (PLS) regression was successfully applied for the rapid quantitative analysis of hemoglobin (HGB) based on human hemolysates samples. Based on the varied divisions for the calibration and prediction sets, an effective modeling approach using stable model parameters was proposed. Among 255 samples, 80 were randomly selected as the validation set. The remaining 175 samples were divided into the calibration set (110 samples) and the prediction set (65 samples) for a total of 30 times with certain similarities based on partial least squares cross-validation predictive basis (PLSPB). The optimal PLS factor was 8, the modeling effects M-SEPAve, M-RP,Ave, M-SEPStd and M-RP,Std were 3.84g/L, 0.967, 0.16g/L and 0.006, respectively, the validation effects V-SEP, V-RP and V-RSEP were 3.59g/L, 0.980 and 2.7%, respectively. It indicated that the method has high prediction precision and well stability. The results show that NIR spectroscopy of hemolysates is accurate to HGB’s determination, and it is hopeful to be applied to clinic. Near-infrared (NIR) spectroscopy combined with the partial least-squares (PLS) regression was successfully applied for the rapid quantitative analysis of hemoglobin (HGB) based on human hemolysates samples. Based on the varied divisions for the calibration and prediction sets, an effective modeling approach using stable model parameters was proposed. Among 255 samples, 80 were randomly selected as the validation set. The remaining 175 samples were divided into the calibration set (110 samples) and the prediction set (65 samples) for a total of 30 times with certain similarities based on partial least squares cross-validation predictive basis (PLSPB). The optimal PLS factor was 8, the modeling effects M-SEPAve, M-RP,Ave, M-SEPStd and M-RP,Std were 3.84g/L, 0.967, 0.16g/L and 0.006, respectively, the validation effects V-SEP, V-RP and V-RSEP were 3.59g/L, 0.980 and 2.7%, respectively. It indicated that the method has high prediction precision and well stability. The results show that NIR spectroscopy of hemolysates is accurate to HGB’s determination, and it is hopeful to be applied to clinic.
机构地区 不详
出处 《American Journal of Analytical Chemistry》 2012年第1期19-23,共5页 美国分析化学(英文)
关键词 Hemolysates HGB NIR Spectroscopy PLS STABILITY Hemolysates HGB NIR Spectroscopy PLS Stability
  • 相关文献

参考文献4

二级参考文献30

共引文献123

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部