期刊文献+

Use of Cucurbit [6] Uril as a Modifier in the Electrochemical Determination of Antitumor Platinum (II) Complex: <i>Trans</i>-[PtCl<sub>2</sub>(Dimethylamine) (Isopropylamine)]. Application to Biological Samples

Use of Cucurbit [6] Uril as a Modifier in the Electrochemical Determination of Antitumor Platinum (II) Complex: <i>Trans</i>-[PtCl<sub>2</sub>(Dimethylamine) (Isopropylamine)]. Application to Biological Samples
下载PDF
导出
摘要 A square wave voltammetry (DPV) method for trans-Pt[Cl2(Dimethylamine)(isopropylamine)] determination is developed. To this end, all the chemical and instrumental variables affecting the determination of trans-Pt[Cl2(Dimethylamine) (isopropylamine)] are optimized. From studies of the mechanisms governing the electrochemical response of trans-Pt[Cl2(Dimethylamine)(isopropylamine)], it was concluded that it was an electrochemically reversible system with an adsorptive oxidation phenomenon. Under optimal conditions, the variation of analytical signal (Ip) with trans-Pt[Cl2(Dimethylamine)(isopropylamine)] concentration was linear in the 0.05 μg·mL-1 to 10 μg·mL-1 range, with a LOD 91 μg·mL-1 of and a LOQ of 303 μg·mL-1, a RSD 1.10% and Er 0.72%. The optimized method was applied to the determination of trans-Pt[Cl2(Dimethylamine)(isopropylamine)] in biological fluids, in human urine and synthetic urine. A square wave voltammetry (DPV) method for trans-Pt[Cl2(Dimethylamine)(isopropylamine)] determination is developed. To this end, all the chemical and instrumental variables affecting the determination of trans-Pt[Cl2(Dimethylamine) (isopropylamine)] are optimized. From studies of the mechanisms governing the electrochemical response of trans-Pt[Cl2(Dimethylamine)(isopropylamine)], it was concluded that it was an electrochemically reversible system with an adsorptive oxidation phenomenon. Under optimal conditions, the variation of analytical signal (Ip) with trans-Pt[Cl2(Dimethylamine)(isopropylamine)] concentration was linear in the 0.05 μg·mL-1 to 10 μg·mL-1 range, with a LOD 91 μg·mL-1 of and a LOQ of 303 μg·mL-1, a RSD 1.10% and Er 0.72%. The optimized method was applied to the determination of trans-Pt[Cl2(Dimethylamine)(isopropylamine)] in biological fluids, in human urine and synthetic urine.
出处 《American Journal of Analytical Chemistry》 2013年第6期314-322,共9页 美国分析化学(英文)
关键词 Trans-[PtCl2(Dimethylamine)(Isopropylamine)] Differential Pulse VOLTAMMETRY (DPV) Square Wave VOLTAMMETRY (SWV) Biological Fluids Human Urine Trans-[PtCl2(Dimethylamine)(Isopropylamine)] Differential Pulse Voltammetry (DPV) Square Wave Voltammetry (SWV) Biological Fluids Human Urine
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部