摘要
A rapid, cost effective and reliable analytical method was developed and validated for the simultaneous determination of four estrogens (17 β-estradiol, 17 α-ethinylestradiol, estrone, and estriol) in compost samples from the biodegradation of biological infectious hazardous wastes. Ultrasonic solvent extraction, using methanol as extraction solvent, coupled with SPE clean-up, using cartridges HLB 60 mg - 6 ml Supelco®<sup></sup> and acetonitrile for reconstitution of eluents, was used for the simultaneous extraction of the four estrogens. Mean recoveries in the range of 98% - 107% were obtained. All compounds were separated in a single gradient run by UHPLC Kinetex<sup>TM</sup> 2.6 μm XB-C18 100 ÅLC (50 × 4.6 mm) column. Analytes were detected via multiple reaction monitoring (MRM) using an AB SCIEX API-5000TM triple quadrupole (Applied Biosystems/MDS SCIEX) with electrospray ionization in negative mode. Isocratic mobile phase of Water:ACN (50:50) resulted to be the optimum. Limits of detection and quantification were on the order of 0.66 ng·g<sup>-1</sup> and 2 ng·g<sup>-1</sup> for all the estrogens. These limits were lower than most of the values reported in the literature for similar matrices. Suitable level of linearity, good repeatability and reproducibility with coefficients of variation is lower than 11.7%, 6.8% and 8.3%, respectively.
A rapid, cost effective and reliable analytical method was developed and validated for the simultaneous determination of four estrogens (17 β-estradiol, 17 α-ethinylestradiol, estrone, and estriol) in compost samples from the biodegradation of biological infectious hazardous wastes. Ultrasonic solvent extraction, using methanol as extraction solvent, coupled with SPE clean-up, using cartridges HLB 60 mg - 6 ml Supelco®<sup></sup> and acetonitrile for reconstitution of eluents, was used for the simultaneous extraction of the four estrogens. Mean recoveries in the range of 98% - 107% were obtained. All compounds were separated in a single gradient run by UHPLC Kinetex<sup>TM</sup> 2.6 μm XB-C18 100 ÅLC (50 × 4.6 mm) column. Analytes were detected via multiple reaction monitoring (MRM) using an AB SCIEX API-5000TM triple quadrupole (Applied Biosystems/MDS SCIEX) with electrospray ionization in negative mode. Isocratic mobile phase of Water:ACN (50:50) resulted to be the optimum. Limits of detection and quantification were on the order of 0.66 ng·g<sup>-1</sup> and 2 ng·g<sup>-1</sup> for all the estrogens. These limits were lower than most of the values reported in the literature for similar matrices. Suitable level of linearity, good repeatability and reproducibility with coefficients of variation is lower than 11.7%, 6.8% and 8.3%, respectively.
作者
Miguel Ángel López Zavala
Blanca Nelly Flores Arriaga
Naoyuki Funamizu
Miguel Ángel López Zavala;Blanca Nelly Flores Arriaga;Naoyuki Funamizu(Water Center forLatin America and the Caribbean, Tecnológico de Monterrey, Col. Tecnológico, Monterrey, Mexico;Department of Environmental Engineering, Graduate School of Engineering, Hokkaido University, Sapporo, Japan)