期刊文献+

Pesticides Recovery and Detection from Agricultural Soil Leachates Using Gas Chromatography Masses with Electron Capture Detector

Pesticides Recovery and Detection from Agricultural Soil Leachates Using Gas Chromatography Masses with Electron Capture Detector
下载PDF
导出
摘要 In this study, it is reported an analytical approach to recover organochlorine pesticides from a clay soil. Soil was physical and chemically characterized. Also pesticides extraction was carried out using packed columns and various aqueous media (H2O-milliQ, NaOH, HCl, SDS, Triton X-114, Humic acids and Acetonitrile). The leachate samples were analyzed on an Agilent Technologies 6890N Gas Chromatograph with electron capture in a# AB002 Column 30.0 m × 250 μm × 0.25 μm calibrated, 25 psi pressure, flow 2.9 ml/min, temperature 25°C, ultra-high purity Helium as the entrainment gas and an elution time of 50 min. The results show that the highest extraction percentage of pollutants in the soil washing was obtained with acetonitrile recovering: p, p’-DDT (91.0%);p, p’-DDE (92.0%);p, p’-DDD (96.0%);aldrin (98.6%);dieldrin (98.0%). With Triton X-114, the extractions recovery was: p, p’-DDT (63.0%);p, p’-DDE (64.0%);p, p’-DDD (65.0%);aldrin (67.0%);dieldrin (72.0%). This study illustrates the potential Applicability of SPME for routine analysis of organochlorine pesticides in soils. In this study, it is reported an analytical approach to recover organochlorine pesticides from a clay soil. Soil was physical and chemically characterized. Also pesticides extraction was carried out using packed columns and various aqueous media (H2O-milliQ, NaOH, HCl, SDS, Triton X-114, Humic acids and Acetonitrile). The leachate samples were analyzed on an Agilent Technologies 6890N Gas Chromatograph with electron capture in a# AB002 Column 30.0 m × 250 μm × 0.25 μm calibrated, 25 psi pressure, flow 2.9 ml/min, temperature 25°C, ultra-high purity Helium as the entrainment gas and an elution time of 50 min. The results show that the highest extraction percentage of pollutants in the soil washing was obtained with acetonitrile recovering: p, p’-DDT (91.0%);p, p’-DDE (92.0%);p, p’-DDD (96.0%);aldrin (98.6%);dieldrin (98.0%). With Triton X-114, the extractions recovery was: p, p’-DDT (63.0%);p, p’-DDE (64.0%);p, p’-DDD (65.0%);aldrin (67.0%);dieldrin (72.0%). This study illustrates the potential Applicability of SPME for routine analysis of organochlorine pesticides in soils.
出处 《American Journal of Analytical Chemistry》 2017年第10期605-616,共12页 美国分析化学(英文)
关键词 Leaching of ORGANOCHLORINE Compounds SURFACTANTS Desorption of PESTICIDES Packed Columns Soil Gas Chromatography-ECD Leaching of Organochlorine Compounds Surfactants Desorption of Pesticides Packed Columns Soil Gas Chromatography-ECD
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部