Optimization of High-Performance Liquid Chromatography Parameters for Purification of Oligonucleotide-A

Optimization of High-Performance Liquid Chromatography Parameters for Purification of Oligonucleotide-A
下载PDF
导出
摘要 The modification of high-performance liquid chromatography parameters leads to a more effective oligonucleotide-A purification process. Using various experimental parameters such as buffer, concentration, and pH, a method for optimizing the purification of an oligonucleotide-A on a reverse-phase C18 column was created. To purify oligonucleotide-A, High-Performance Liquid Chromatography (HPLC), Ultraviolet-Visible Spectrophotometry (UV-Vis), Liquid Chromatography-Mass Spectrometry (LC-MS), and lyophilization were used. Chromatographic data were collected with a semi-prep HPLC system, quantified with the UV-Vis technique, and validated with the LC-MS method. The most optimized parameters found to obtain the purity of 93.0% are 40 mM triethylammonium bicarbonate (TEAB) buffer with pH 7, which is approximately 6.0% higher than the reported method of which the purity is 87.0%. However, the yield under these conditions was reduced by about 5%. The worst possible optimized settings that resulted in the lowest purity (84.0%) and yield (69.0%) are 10 mM ammonium acetate (NH<sub>4</sub>CH<sub>3</sub>CO<sub>2</sub>) with pH 7. The modification of high-performance liquid chromatography parameters leads to a more effective oligonucleotide-A purification process. Using various experimental parameters such as buffer, concentration, and pH, a method for optimizing the purification of an oligonucleotide-A on a reverse-phase C18 column was created. To purify oligonucleotide-A, High-Performance Liquid Chromatography (HPLC), Ultraviolet-Visible Spectrophotometry (UV-Vis), Liquid Chromatography-Mass Spectrometry (LC-MS), and lyophilization were used. Chromatographic data were collected with a semi-prep HPLC system, quantified with the UV-Vis technique, and validated with the LC-MS method. The most optimized parameters found to obtain the purity of 93.0% are 40 mM triethylammonium bicarbonate (TEAB) buffer with pH 7, which is approximately 6.0% higher than the reported method of which the purity is 87.0%. However, the yield under these conditions was reduced by about 5%. The worst possible optimized settings that resulted in the lowest purity (84.0%) and yield (69.0%) are 10 mM ammonium acetate (NH<sub>4</sub>CH<sub>3</sub>CO<sub>2</sub>) with pH 7.
作者 Christina Perez Mubeen Rani Tuan Phan Christina Perez;Mubeen Rani;Tuan Phan(Department of Chemistry, Texas Southern University, Houston, USA)
出处 《American Journal of Analytical Chemistry》 2022年第2期39-50,共12页 美国分析化学(英文)
关键词 PURIFICATION High-Performance Liquid Chromatography Oligonucleotide-A Dipotassium Phosphate Triethylammonium Acetate Triethylammonium Bicarbonate Ammonium Acetate Purification High-Performance Liquid Chromatography Oligonucleotide-A Dipotassium Phosphate Triethylammonium Acetate Triethylammonium Bicarbonate Ammonium Acetate
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部