摘要 For the quantitative determination of Fulvestrant, Benzyl alcohol, and Benzyl benzoate in Fulvestrant injection, an original RP-HPLC approach was developed. The gradient method was developed using HPLC and a Phenomenex Luna C8, 150 × 4.6 mm, i.d 3.0 μm particle size column with a gradient programme of mobile phases A and B. With a flow rate of 1.5 mL/minute, injection volume of 10 μL, and column temperature of 35°C, UV wavelength detection at 254 nm for Benzyl alcohol and Benzoyl Benzoate and 280 nm for Fulvestrant, mobile phase-A consists of DI water and mobile phase-B consists of Acetonitrile. The current study describes a single HPLC method for developing a Fulvestrant (Active), Benzyl alcohol (Cosolvent), and Benzyl Benzoate (Cosolvent) assay for Fulvestrant injection. The assay method was determined to be suitable for quantifying three components in the pharmaceutical product and was verified according to ICH guidelines. For the quantitative determination of Fulvestrant, Benzyl alcohol, and Benzyl benzoate in Fulvestrant injection, an original RP-HPLC approach was developed. The gradient method was developed using HPLC and a Phenomenex Luna C8, 150 × 4.6 mm, i.d 3.0 μm particle size column with a gradient programme of mobile phases A and B. With a flow rate of 1.5 mL/minute, injection volume of 10 μL, and column temperature of 35°C, UV wavelength detection at 254 nm for Benzyl alcohol and Benzoyl Benzoate and 280 nm for Fulvestrant, mobile phase-A consists of DI water and mobile phase-B consists of Acetonitrile. The current study describes a single HPLC method for developing a Fulvestrant (Active), Benzyl alcohol (Cosolvent), and Benzyl Benzoate (Cosolvent) assay for Fulvestrant injection. The assay method was determined to be suitable for quantifying three components in the pharmaceutical product and was verified according to ICH guidelines.
作者 Arjuna Rao Nekkalapudi Venu Gopal Veldi Sreenivas Pippalla Arjuna Rao Nekkalapudi;Venu Gopal Veldi;Sreenivas Pippalla(Career Point University, CP Tower 1, IPIA, Kota, Rajasthan, India;HTS Bio Pharma, Aleap Industries Estate, Pragathi Nagar, Telangana, India;Sikkim Professional University, Gangtok, India)
出处 《American Journal of Analytical Chemistry》 CAS 2022年第7期229-240,共12页 美国分析化学(英文)
关键词 FULVESTRANT Injection Formulation HPLC ASSAY Benzyl Alcohol and Benzyl Benzoate Fulvestrant Injection Formulation HPLC Assay Benzyl Alcohol and Benzyl Benzoate
  • 相关文献

参考文献6

二级参考文献8

共引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部