期刊文献+

Osteoconductivity of Hydrophilic Surfaces of Zr-9Nb-3Sn Alloy with Hydrothermal Treatment 被引量:1

Osteoconductivity of Hydrophilic Surfaces of Zr-9Nb-3Sn Alloy with Hydrothermal Treatment
下载PDF
导出
摘要 Zirconium and its alloys are more suitable materials for implant surgery to be performed in a magnetic resonance imaging scanner compared with other implant materials. Although they have high anticorrosion properties in the body, as do titanium and its alloys, they have little use as implants in contact with bone because of their low osteoconductivity (bone-implant contact ratio). To improve the osteoconductivity of zirconium, niobium, and Zr-9Nb-3Sn alloy, we applied a single- step hydrothermal surface treatment using distilled water at a temperature of 180°C for 3 h. The hydrothermally treated samples were stored in a ×5 phosphate-buffered saline (PBS(-)) solution to keep or to improve the water contact angle (WCA), which has a strongly positive effect on osteoconductivity. The specimen surfaces were characterized using scanning electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy, surface roughness, and contact angle measurement using a 2 μL droplet of distilled water. The relationship between WCA and osteoconductivity for various surface modifications was examined using in vivo tests. The results showed that a superhydrophilic surface with a WCA ≤ 10° and a high osteoconductivity of up to 40% in cortical bone, about four times higher than the as-polished Zr-9Nb-3Sn and its pure alloy elements, was provided by the combination of hydrothermal surface treatment and storage in ×5 PBS(-). Zirconium and its alloys are more suitable materials for implant surgery to be performed in a magnetic resonance imaging scanner compared with other implant materials. Although they have high anticorrosion properties in the body, as do titanium and its alloys, they have little use as implants in contact with bone because of their low osteoconductivity (bone-implant contact ratio). To improve the osteoconductivity of zirconium, niobium, and Zr-9Nb-3Sn alloy, we applied a single- step hydrothermal surface treatment using distilled water at a temperature of 180°C for 3 h. The hydrothermally treated samples were stored in a ×5 phosphate-buffered saline (PBS(-)) solution to keep or to improve the water contact angle (WCA), which has a strongly positive effect on osteoconductivity. The specimen surfaces were characterized using scanning electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy, surface roughness, and contact angle measurement using a 2 μL droplet of distilled water. The relationship between WCA and osteoconductivity for various surface modifications was examined using in vivo tests. The results showed that a superhydrophilic surface with a WCA ≤ 10° and a high osteoconductivity of up to 40% in cortical bone, about four times higher than the as-polished Zr-9Nb-3Sn and its pure alloy elements, was provided by the combination of hydrothermal surface treatment and storage in ×5 PBS(-).
出处 《Journal of Biomaterials and Nanobiotechnology》 2015年第3期126-134,共9页 生物材料与纳米技术(英文)
关键词 ZIRCONIUM ALLOYS HYDROTHERMAL HYDROPHILIC in VIVO OSTEOCONDUCTIVITY Zirconium Alloys Hydrothermal Hydrophilic in Vivo Osteoconductivity
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部