期刊文献+

Investigation of Surface Free Energy for PTFE Polymer by Bipolar Argon Plasma Treatment

Investigation of Surface Free Energy for PTFE Polymer by Bipolar Argon Plasma Treatment
下载PDF
导出
摘要 The low ion energy argon plasma was used for surface modification of Poly tetra fluoroethylene (PTFE) polymer. The plasma was generated between two plane metal electrode by using 50 kHz bipolar power supply. The plasma treated surface was characterized by atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS). The surface free energy (SFE) of plasma treated surface was calculated from contact angle measurement. SFE increases from 33.39 mJ/m2 to 41.40 mJ/m2 with the increase in plasma treatment time and the corresponding contact angle changed from 76? to 60?. XPS study shows that F/C ratio change from 1.8 (untreated) to 1.3 (treated) and O/C ratio changes from 0.094 (untreated) to 0.148 (treated). The XPS analysis shows that both F1s and the C1s spectra for PTFE are marginally modified by plasma treatment. AFM study shows that the average surface roughness (Ra) increased from 8.5 nm to 22.8 nm after plasma treatment. Vicker’s micro hardness of the film increases upon plasma treatment. The increase in SFE after plasma treatment is attributed to the functionalization of the polymer surface with hydrophilic groups as supported from the above observations. The low ion energy argon plasma was used for surface modification of Poly tetra fluoroethylene (PTFE) polymer. The plasma was generated between two plane metal electrode by using 50 kHz bipolar power supply. The plasma treated surface was characterized by atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS). The surface free energy (SFE) of plasma treated surface was calculated from contact angle measurement. SFE increases from 33.39 mJ/m2 to 41.40 mJ/m2 with the increase in plasma treatment time and the corresponding contact angle changed from 76? to 60?. XPS study shows that F/C ratio change from 1.8 (untreated) to 1.3 (treated) and O/C ratio changes from 0.094 (untreated) to 0.148 (treated). The XPS analysis shows that both F1s and the C1s spectra for PTFE are marginally modified by plasma treatment. AFM study shows that the average surface roughness (Ra) increased from 8.5 nm to 22.8 nm after plasma treatment. Vicker’s micro hardness of the film increases upon plasma treatment. The increase in SFE after plasma treatment is attributed to the functionalization of the polymer surface with hydrophilic groups as supported from the above observations.
出处 《Journal of Surface Engineered Materials and Advanced Technology》 2012年第2期132-136,共5页 表面工程材料与先进技术期刊(英文)
关键词 PTFE Surface Energy XPS AFM MICROHARDNESS PTFE Surface Energy XPS AFM Microhardness
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部