摘要 Electrochemical etching of titanium alloy in a fluoride-containing electrolyte results in ordered nanotextured surfaces. The reproducibility of nanotextured surfaces depends on several process parameters, most notably the fluoride ion concentration in the electrolyte. In the present work, electrochemical etching of Ti6Al4V alloy foils in ethylene glycol containing 0.66 wt% NH4F and 2% deionized water was carried out at 60 V for 45 minutes. This paper describes the depletion of fluoride ion concentration and contamination of electrolyte upon reuse. Inductively coupled plasma-optical emission spectroscopy was used to measure the dissolution of metal oxides in the electrolyte during etching. We found increasing concentration of the alloy elements Ti, Al, V contaminated the electrolyte due to repeated reuse of the electrolyte. The results show an appreciable log-linear depletion of fluoride ion concentration resulting in a changed surface morphology, chemical composition and etched volume. This paper provides an important insight to changes in surface morphology and surface chemistry with extended reuse of the etching electrolyte, useful for regulatory approvals. Electrochemical etching of titanium alloy in a fluoride-containing electrolyte results in ordered nanotextured surfaces. The reproducibility of nanotextured surfaces depends on several process parameters, most notably the fluoride ion concentration in the electrolyte. In the present work, electrochemical etching of Ti6Al4V alloy foils in ethylene glycol containing 0.66 wt% NH4F and 2% deionized water was carried out at 60 V for 45 minutes. This paper describes the depletion of fluoride ion concentration and contamination of electrolyte upon reuse. Inductively coupled plasma-optical emission spectroscopy was used to measure the dissolution of metal oxides in the electrolyte during etching. We found increasing concentration of the alloy elements Ti, Al, V contaminated the electrolyte due to repeated reuse of the electrolyte. The results show an appreciable log-linear depletion of fluoride ion concentration resulting in a changed surface morphology, chemical composition and etched volume. This paper provides an important insight to changes in surface morphology and surface chemistry with extended reuse of the etching electrolyte, useful for regulatory approvals.
作者 Sachin M. Bhosle Radheshyam Tewari Craig R. Friedrich Sachin M. Bhosle;Radheshyam Tewari;Craig R. Friedrich(Multi Scale Technologies Institute, Michigan Technological University, Houghton, USA;Vidya Pratishthan’s Kamalnayan Bajaj Institute of Engineering and Technology, Baramati, India)
出处 《Journal of Surface Engineered Materials and Advanced Technology》 2016年第4期164-175,共13页 表面工程材料与先进技术期刊(英文)
关键词 IMPLANTS Anodization TiO2 Nanotubes Fluoride Concentration TITANIUM Implants Anodization TiO2 Nanotubes Fluoride Concentration Titanium
  • 相关文献

同被引文献1

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部