期刊文献+

Design and Implementation Challenges of Microelectrode Arrays: A Review 被引量:1

Design and Implementation Challenges of Microelectrode Arrays: A Review
下载PDF
导出
摘要 The emerging field of neuroprosthetics is focused on design and implementation of neural prostheses to restore some of the lost neural functions. Remarkable progress has been reported at most bioelectronic levels—particularly the various brain-machine interfaces (BMIs)—but the electrode-tissue contacts (ETCs) remain one of the major obstacles. The success of these BMIs relies on electrodes which are in contact with the neural tissue. Biological response to chronic implantation of Microelectrode arrays (MEAs) is an essential factor in determining a successful electrode design. By altering the material compositions and geometries of the arrays, fabrication techniques of MEAs insuring these ETCs try to obtain consistent recording signals from small groups of neurons without losing microstimulation capabilities, while maintaining low-impedance pathways for charge injection, high-charge transfer, and high-spatial resolution in recent years. So far, none of these attempts have led to a major breakthrough. Clearly, much work still needs to be done to accept a standard model of MEAs for clinical purposes. In this paper, we review different microfabrication techniques of MEAs with their advantages and drawbacks, and comment on various coating materials to enhance electrode performance. Then, we propose high-density, three-dimensional (3D), silicon-based MEAs using micromachining methods. The geometries that will be used include arrays of penetrating variable-height probes. The emerging field of neuroprosthetics is focused on design and implementation of neural prostheses to restore some of the lost neural functions. Remarkable progress has been reported at most bioelectronic levels—particularly the various brain-machine interfaces (BMIs)—but the electrode-tissue contacts (ETCs) remain one of the major obstacles. The success of these BMIs relies on electrodes which are in contact with the neural tissue. Biological response to chronic implantation of Microelectrode arrays (MEAs) is an essential factor in determining a successful electrode design. By altering the material compositions and geometries of the arrays, fabrication techniques of MEAs insuring these ETCs try to obtain consistent recording signals from small groups of neurons without losing microstimulation capabilities, while maintaining low-impedance pathways for charge injection, high-charge transfer, and high-spatial resolution in recent years. So far, none of these attempts have led to a major breakthrough. Clearly, much work still needs to be done to accept a standard model of MEAs for clinical purposes. In this paper, we review different microfabrication techniques of MEAs with their advantages and drawbacks, and comment on various coating materials to enhance electrode performance. Then, we propose high-density, three-dimensional (3D), silicon-based MEAs using micromachining methods. The geometries that will be used include arrays of penetrating variable-height probes.
出处 《Materials Sciences and Applications》 2013年第8期483-495,共13页 材料科学与应用期刊(英文)
关键词 MICROELECTRODE ARRAYS Electrodes-Tissues CONTACTS MICROELECTRODE IMPEDANCE Neural PROSTHESIS Microelectrode Arrays Electrodes-Tissues Contacts Microelectrode Impedance Neural Prosthesis
  • 相关文献

参考文献1

二级参考文献9

  • 1Duan C L,Biol Signals Recept,1999年,8卷,256页
  • 2Duan C L,Biol Signals Recept,1999年,8卷,261页
  • 3Lu G W,Biol Signals Recept,1999年,8卷,247页
  • 4Xie J,Biol Signals Recept,1999年,8卷,267页
  • 5Zhang W L,Biol Signals Recept,1999年,8卷,275页
  • 6Lu G W,Neurochem Res,1999年,24卷,5期,625页
  • 7Lu G W,基础医学与临床,1997年,17卷,1期,7页
  • 8Lu G W,中国神经科学杂志,1996年,3卷,2期,92页
  • 9Yang T L,Motor Med,1983年,5卷,4期,47页

共引文献11

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部