期刊文献+

How Polydopamine Modulates Biological Responses to PTFE Prostheses

How Polydopamine Modulates Biological Responses to PTFE Prostheses
下载PDF
导出
摘要 Diaphragm repair after congenital diaphragmatic hernia is associated with hernia recurrence due to prosthesis failure. Expanded polytetrafluoroethylene (e-PTFE), a synthetic non-degradable biomaterial, is currently used for those diaphragmatic defect repairs. The drawback of e-PTFE is its poor wettability that leads to coating difficulties, bonding that could favor implant integration. However, polydopamine (PDA) can be deposited as well on organic as on inorganic substrates. Therefore, we assessed the biological responses of a clinically used e-PTFE biomaterial treated with PDA in two different manners: one impregnated with PDA and the other coated with a one side PDA film. Mechanical properties of the raw e-PTFE, the PDA soaked biomaterial and the PDA coated surface were characterized by colloidal probe atomic force microscopy. Behaviors of primary human fibroblasts and Wharton’s jelly stem cells were investigated by electron microscopy. Findings reveal that the mechanical properties at the microscopic scale are not modified by the PDA treatments. Cells spread onto both PDA functionalized substrates. In addition, microscopic observations disclose numerous focal cell contacts, evidencing cell attachment, and cytoplasmic projections particularly with the nanoscale PDA coating. Results clearly suggest that PDA in general but above all the PDA coating enhance cellular colonization of the implant material. Diaphragm repair after congenital diaphragmatic hernia is associated with hernia recurrence due to prosthesis failure. Expanded polytetrafluoroethylene (e-PTFE), a synthetic non-degradable biomaterial, is currently used for those diaphragmatic defect repairs. The drawback of e-PTFE is its poor wettability that leads to coating difficulties, bonding that could favor implant integration. However, polydopamine (PDA) can be deposited as well on organic as on inorganic substrates. Therefore, we assessed the biological responses of a clinically used e-PTFE biomaterial treated with PDA in two different manners: one impregnated with PDA and the other coated with a one side PDA film. Mechanical properties of the raw e-PTFE, the PDA soaked biomaterial and the PDA coated surface were characterized by colloidal probe atomic force microscopy. Behaviors of primary human fibroblasts and Wharton’s jelly stem cells were investigated by electron microscopy. Findings reveal that the mechanical properties at the microscopic scale are not modified by the PDA treatments. Cells spread onto both PDA functionalized substrates. In addition, microscopic observations disclose numerous focal cell contacts, evidencing cell attachment, and cytoplasmic projections particularly with the nanoscale PDA coating. Results clearly suggest that PDA in general but above all the PDA coating enhance cellular colonization of the implant material.
出处 《Materials Sciences and Applications》 2019年第5期377-392,共16页 材料科学与应用期刊(英文)
关键词 BIOMATERIALS Expanded Polytetrafluoroethylene POLYDOPAMINE FUNCTIONALIZATION Electron MICROSCOPY Biomaterials Expanded Polytetrafluoroethylene Polydopamine Functionalization Electron Microscopy
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部