摘要 This study presents a significant contribution to the field of water quality assessment and sustainable water management practices. By evaluating the levels of total dissolved solids (TDS) in seawater intakes within Al-Khobar desalination production system, the study addresses a crucial aspect of water treatment and environmental impact assessment. The findings provide valuable insights into the variations and trends of TDS levels across different phases of the system, highlighting the importance of monitoring and management strategies. The study provided both gravimetric total dissolved solids (TDS) and electrical conductivity (EC) measurements to analyze TDS calculation factor and evaluate measurement accuracy. Results revealed significant variations in TDS levels across the sampling locations, with phase-2 exhibiting higher levels and greater fluctuations. Phase-3 displayed similar trends but with lower TDS levels, while phase-4 showed slightly different behavior with higher average TDS levels. EC measurements demonstrated a strong correlation with TDS, providing a reliable estimation. However, additional methods such as gravimetric analysis should be employed to confirm TDS measurements. The findings contribute to understanding water quality in the Al-Khobar desalination system, aiding in monitoring, management, and decision-making processes for water treatment and environmental impact assessment. The study enhances the credibility of water quality assessments and supports sustainable water management practices. This study presents a significant contribution to the field of water quality assessment and sustainable water management practices. By evaluating the levels of total dissolved solids (TDS) in seawater intakes within Al-Khobar desalination production system, the study addresses a crucial aspect of water treatment and environmental impact assessment. The findings provide valuable insights into the variations and trends of TDS levels across different phases of the system, highlighting the importance of monitoring and management strategies. The study provided both gravimetric total dissolved solids (TDS) and electrical conductivity (EC) measurements to analyze TDS calculation factor and evaluate measurement accuracy. Results revealed significant variations in TDS levels across the sampling locations, with phase-2 exhibiting higher levels and greater fluctuations. Phase-3 displayed similar trends but with lower TDS levels, while phase-4 showed slightly different behavior with higher average TDS levels. EC measurements demonstrated a strong correlation with TDS, providing a reliable estimation. However, additional methods such as gravimetric analysis should be employed to confirm TDS measurements. The findings contribute to understanding water quality in the Al-Khobar desalination system, aiding in monitoring, management, and decision-making processes for water treatment and environmental impact assessment. The study enhances the credibility of water quality assessments and supports sustainable water management practices.
作者 Ahmed Al-Kubaish Jamal Salama Waleed Al-Jurayan Ahmed Al-Kubaish;Jamal Salama;Waleed Al-Jurayan(Water Quality Section, Al-Khobar Production System, Saline Water Conversion Corporation, Al-Khobar, Saudi Arabia)
机构地区 Water Quality Section
出处 《Computational Water, Energy, and Environmental Engineering》 2024年第1期1-12,共12页 水能与环境工程(英文)
关键词 Total Dissolved Solids CONDUCTIVITY Seawater DESALINATION Total Dissolved Solids Conductivity Seawater Desalination
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部