期刊文献+

Determination of Triclocarban, Triclosan and Methyl-Triclosan in Environmental Water by Silicon Dioxide/Polystyrene Composite Microspheres Solid-Phase Extraction Combined with HPLC-ESI-MS 被引量:1

Determination of Triclocarban, Triclosan and Methyl-Triclosan in Environmental Water by Silicon Dioxide/Polystyrene Composite Microspheres Solid-Phase Extraction Combined with HPLC-ESI-MS
下载PDF
导出
摘要 This paper developed a sensitive and efficient analytical method for triclocarban (TCC), triclosan (TCS) and Methyl-triclosan (MTCS) determination in environmental water, which involves enrichment by using silicon dioxide/polystyrene composite microspheres solid-phase extraction and detection with HPLC-ESI-MS. The influence of several operational parameters, including the eluant and its volume, the flow rate and acidity of water sample were investigated and optimized. Under the optimum conditions, the limits of detection were 1.0 ng/L, 2.5 and 4.5 ng/L for TCC, TCS, and MTCS, respectively. The linearity of the method was observed in the range of 5-2000 ng/L, with correlation coefficients (r2) >.99. The spiked recoveries of TCC, TCS and MTCS in water sampleswereachieved in the range of 89.5% -96.8% with RSD below 5.7%. The proposed method has been successfully applied to analyze real water samples and satisfactory results were achieved. This paper developed a sensitive and efficient analytical method for triclocarban (TCC), triclosan (TCS) and Methyl-triclosan (MTCS) determination in environmental water, which involves enrichment by using silicon dioxide/polystyrene composite microspheres solid-phase extraction and detection with HPLC-ESI-MS. The influence of several operational parameters, including the eluant and its volume, the flow rate and acidity of water sample were investigated and optimized. Under the optimum conditions, the limits of detection were 1.0 ng/L, 2.5 and 4.5 ng/L for TCC, TCS, and MTCS, respectively. The linearity of the method was observed in the range of 5-2000 ng/L, with correlation coefficients (r2) >.99. The spiked recoveries of TCC, TCS and MTCS in water sampleswereachieved in the range of 89.5% -96.8% with RSD below 5.7%. The proposed method has been successfully applied to analyze real water samples and satisfactory results were achieved.
出处 《Journal of Geoscience and Environment Protection》 2013年第2期13-17,共5页 地球科学和环境保护期刊(英文)
关键词 TRICLOCARBAN TRICLOSAN SOLID-PHASE Extraction Silicon Dioxide/Polystyrene Composite MICROSPHERES HPLC-ESI-MS/MS Triclocarban Triclosan Solid-Phase Extraction Silicon Dioxide/Polystyrene Composite Microspheres HPLC-ESI-MS/MS
  • 相关文献

同被引文献3

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部