Physicochemical and Bacteriological Quality of Groundwater, East of Nile Delta of Egypt 被引量:1

Physicochemical and Bacteriological Quality of Groundwater, East of Nile Delta of Egypt
下载PDF
导出
摘要 Groundwater is an important source of freshwater for drinking and irrigation purposes, and hence protecting it against depletion and deterioration is extremely required. Groundwater could get contaminated physically, chemically, or microbiologically. Each type of contamination is linked to different sources and in turn imposes different types of health problems and consequences. A water sample from Bahr Al-Baqar Wastewater drain and 13 groundwater samples were collected for physiochemical and bacteriological analyses to evaluate groundwater contamination in As-Salihiyyah and adjacent areas, east of Nile Delta of Egypt. Nitrate, COD, and BOD values collected from Bahr Al-Baqr drain and groundwater exceeded the Egyptian maximum permissible limit for drinking water (0.5, 6, 10, respectively). The total number of viable microorganisms (TVC) test for Bahr Al-Baqar drain was recorded as more than 300 CFU/mL, and the total coliform recorded 1100 MPN/100ml, indicating high level of contamination. The high count of the TVC (16-↑300 CFU/mL) for groundwater and the total coliform (3 - 1100 MPN/100ml) indicated that groundwater is contaminated and unsafe for drinking and might be affected by Bahr Al-Baqar wastewater drain. Groundwater is an important source of freshwater for drinking and irrigation purposes, and hence protecting it against depletion and deterioration is extremely required. Groundwater could get contaminated physically, chemically, or microbiologically. Each type of contamination is linked to different sources and in turn imposes different types of health problems and consequences. A water sample from Bahr Al-Baqar Wastewater drain and 13 groundwater samples were collected for physiochemical and bacteriological analyses to evaluate groundwater contamination in As-Salihiyyah and adjacent areas, east of Nile Delta of Egypt. Nitrate, COD, and BOD values collected from Bahr Al-Baqr drain and groundwater exceeded the Egyptian maximum permissible limit for drinking water (0.5, 6, 10, respectively). The total number of viable microorganisms (TVC) test for Bahr Al-Baqar drain was recorded as more than 300 CFU/mL, and the total coliform recorded 1100 MPN/100ml, indicating high level of contamination. The high count of the TVC (16-↑300 CFU/mL) for groundwater and the total coliform (3 - 1100 MPN/100ml) indicated that groundwater is contaminated and unsafe for drinking and might be affected by Bahr Al-Baqar wastewater drain.
作者 Muhammad Gomaah Amany Ramadan Mona M. El-Shazly Muhammad Gomaah;Amany Ramadan;Mona M. El-Shazly(Department of Hydrogeochemistry, Desert Research Center, Cairo, Egypt;Department of Soil Fertility and Microbiology, Desert Research Center, Cairo, Egypt)
出处 《Journal of Geoscience and Environment Protection》 2021年第1期97-106,共10页 地球科学和环境保护期刊(英文)
关键词 East of Nile Delta Bahr Al-Baqar Groundwater Contamination East of Nile Delta Bahr Al-Baqar Groundwater Contamination
  • 相关文献

同被引文献1

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部