期刊文献+

Numerical Analysis of Settlement Response of Shallow Footing Subjected to Heavy Rainfall and Flood Events

Numerical Analysis of Settlement Response of Shallow Footing Subjected to Heavy Rainfall and Flood Events
下载PDF
导出
摘要 The US and many parts around the world have experienced prolonged periods of heavy rainfall, severe floods, and droughts over the past 50 years. This study investigates the impacts of extreme hydrological events such as heavy rainfall and flood on the settlement behavior of continuous footing installed in unsaturated soil using a coupled Geotechnical-Hydrological finite element software, PLAXIS 2D. Initially, the effect of different degrees of saturation on the settlement behavior of the continuous footing of widths 1.5 m, 3.0 m, and 4.5 m w</span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">as</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> analyzed by applying a mechanical load. Then the settlement behavior of the footing was analyzed by applying heavy rainfall of intensity 102 mm/day for six days. Finally, the settlement behavior of the footing was analyzed by applying a flood head of 2.5 meters for seven days. The results indicated that the wetting front movement during heavy rainfall and flooding led to the weakening of soil strength and stiffness and induced additional settlements. The additional settlement induced by the flood was significantly higher than the heavy rainfall. The differential settlement was higher when the rainfall was applied on one side of the footing. The rebound of the elastic settlement was uniquely noticed when the flood head receded with time. The results indicated that not all the settlements were induced by the soil saturation but also due to the hydrostatic loading due to the flood head. The settlements induced by the flooding exceeded the allowable settlement of 25 mm, resulting in failure. These additional settlements caused by heavy rainfall and flood will lead to poor serviceability of the structures and cause the failure of the footing. The US and many parts around the world have experienced prolonged periods of heavy rainfall, severe floods, and droughts over the past 50 years. This study investigates the impacts of extreme hydrological events such as heavy rainfall and flood on the settlement behavior of continuous footing installed in unsaturated soil using a coupled Geotechnical-Hydrological finite element software, PLAXIS 2D. Initially, the effect of different degrees of saturation on the settlement behavior of the continuous footing of widths 1.5 m, 3.0 m, and 4.5 m w</span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">as</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> analyzed by applying a mechanical load. Then the settlement behavior of the footing was analyzed by applying heavy rainfall of intensity 102 mm/day for six days. Finally, the settlement behavior of the footing was analyzed by applying a flood head of 2.5 meters for seven days. The results indicated that the wetting front movement during heavy rainfall and flooding led to the weakening of soil strength and stiffness and induced additional settlements. The additional settlement induced by the flood was significantly higher than the heavy rainfall. The differential settlement was higher when the rainfall was applied on one side of the footing. The rebound of the elastic settlement was uniquely noticed when the flood head receded with time. The results indicated that not all the settlements were induced by the soil saturation but also due to the hydrostatic loading due to the flood head. The settlements induced by the flooding exceeded the allowable settlement of 25 mm, resulting in failure. These additional settlements caused by heavy rainfall and flood will lead to poor serviceability of the structures and cause the failure of the footing.
作者 Nadarajah Ravichandran Tharshikka Vickneswaran Siddharth Marathe Vishnu Saketh Jella Nadarajah Ravichandran;Tharshikka Vickneswaran;Siddharth Marathe;Vishnu Saketh Jella(Glenn Department of Civil Engineering, Clemson University, Lowry Hall, Clemson, US)
出处 《International Journal of Geosciences》 2021年第2期138-158,共21页 地球科学国际期刊(英文)
关键词 Coupled Flow Deformation Unsaturated Soils Shallow Footings Heavy Rainfall FLOOD Drought Coupled Flow Deformation Unsaturated Soils Shallow Footings Heavy Rainfall Flood Drought
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部