期刊文献+

Passive Sampling of Ambient Nitrogen Dioxide Using Local Tubes

Passive Sampling of Ambient Nitrogen Dioxide Using Local Tubes
下载PDF
导出
摘要 Traditional active and automated sampling of nitrogen dioxide (NO2) monitoring techniques require expensive instrumentation which is not easily adapted for large scale monitoring by resource limited countries. This paper presents the use of locally available relatively cheaper polyethylene tubes to be developed as passive diffusive sampler and use for monitoring of ambient nitrogen dioxide using Triethanolamine (TEA) as absorbent. After extraction with double distilled water, modified Griese-Saltzmann method is used for analysis of nitrite adduct formed due to reaction of NO2 with TEA using spectrophotometer. The results are compared with Ferm-Badge type passive samplers from IVL- Sweden and high volume sampling methods. The detection limits of the passive sampling methods were found to be suitable to be use in tested environment and precision of the method as expressed as Coefficient of variation are good enough for monitoring of NO2 in ambient air of Kathmandu. The method shows strong correlation with high volume sampler and no significant difference with Ferm-Badge—IVL samplers at p = 0.05. Traditional active and automated sampling of nitrogen dioxide (NO2) monitoring techniques require expensive instrumentation which is not easily adapted for large scale monitoring by resource limited countries. This paper presents the use of locally available relatively cheaper polyethylene tubes to be developed as passive diffusive sampler and use for monitoring of ambient nitrogen dioxide using Triethanolamine (TEA) as absorbent. After extraction with double distilled water, modified Griese-Saltzmann method is used for analysis of nitrite adduct formed due to reaction of NO2 with TEA using spectrophotometer. The results are compared with Ferm-Badge type passive samplers from IVL- Sweden and high volume sampling methods. The detection limits of the passive sampling methods were found to be suitable to be use in tested environment and precision of the method as expressed as Coefficient of variation are good enough for monitoring of NO2 in ambient air of Kathmandu. The method shows strong correlation with high volume sampler and no significant difference with Ferm-Badge—IVL samplers at p = 0.05.
出处 《Journal of Environmental Protection》 2012年第2期177-186,共10页 环境保护(英文)
关键词 NITROGEN Dioxide PASSIVE SAMPLER Diffusive Sampling Nitrogen Dioxide Passive Sampler Diffusive Sampling
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部