期刊文献+

Synthesis and Evaluation of CQC-1—An Oil Field Scale Inhibitor

Synthesis and Evaluation of CQC-1—An Oil Field Scale Inhibitor
下载PDF
导出
摘要 Most of the oil wells enter the middle and late stages of extraction. After one oil extraction, water injection is needed for secondary extraction. With a large amount of calcium and magnesium ions in the water, which is easy to form a large amount of insoluble scale, its formed barium sulfate and strontium sulfate scale are more difficult to handle than carbonate scale. In order to reduce the difficulty of oil production work, this paper mainly targeted the sulfate scale for experiments, and prepared the scale retardant agent CQC-1. Through orthogonal experimental screening, the mass ratio of itaconate acid:methacrylic acid:AMPS:sodium acrylic sulfonate was 2:1:1:1, increase the amount of evocating agent was 8% and the reaction time was 4h, the sulfate scale inhibitor synthesized at the temperature of 80°C had the best performance. Using scale resistance rate, degradation and salt-resistance, the experimental results showed that the scale resistance rate of CQC-1 reached 90.46%. In the four-week degradation experiment, the degradation rate reached over 71% and was maintained by 80.65% at 150°C, while the scale resistance rate still reached 80.35% in simulated saline. It has excellent scale resistance, temperature resistance, salt-resistance and degradation, and has good development prospects. Most of the oil wells enter the middle and late stages of extraction. After one oil extraction, water injection is needed for secondary extraction. With a large amount of calcium and magnesium ions in the water, which is easy to form a large amount of insoluble scale, its formed barium sulfate and strontium sulfate scale are more difficult to handle than carbonate scale. In order to reduce the difficulty of oil production work, this paper mainly targeted the sulfate scale for experiments, and prepared the scale retardant agent CQC-1. Through orthogonal experimental screening, the mass ratio of itaconate acid:methacrylic acid:AMPS:sodium acrylic sulfonate was 2:1:1:1, increase the amount of evocating agent was 8% and the reaction time was 4h, the sulfate scale inhibitor synthesized at the temperature of 80°C had the best performance. Using scale resistance rate, degradation and salt-resistance, the experimental results showed that the scale resistance rate of CQC-1 reached 90.46%. In the four-week degradation experiment, the degradation rate reached over 71% and was maintained by 80.65% at 150°C, while the scale resistance rate still reached 80.35% in simulated saline. It has excellent scale resistance, temperature resistance, salt-resistance and degradation, and has good development prospects.
作者 Qichao Cao Xintong Li Xiong Wang Song Wang Qichao Cao;Xintong Li;Xiong Wang;Song Wang(Yangtze University, Jingzhou, China)
机构地区 Yangtze University
出处 《Open Journal of Yangtze Oil and Gas》 2022年第1期13-25,共13页 长江油气(英文版)
关键词 Scale Resistance Agent Synthetic Monomer Synthetic Conditions Performance Evaluation Scale Resistance Rate Scale Resistance Agent Synthetic Monomer Synthetic Conditions Performance Evaluation Scale Resistance Rate
  • 相关文献

参考文献11

二级参考文献134

共引文献69

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部