唐山地区将功率因数纳入电结算,执行功率因数考核基数为0.9,我单位当月实际功率因数为0.71,受到3万元处罚.为了提高用电功率因数,采取了调整变压器分接头、加强电容器补偿等措施,使功率因数保持在0.92左右.
In Tangshan area, the power factor is included in the power settlement and the base of the power factor is 0.9. The actual power factor of the unit is 0.71, and the penalty is 30,000 Yuan. In order to improve the power factor, adopted to adjust the transformer tap, to strengthen the capacitor compensation and other measures to maintain the power factor of 0.92 or so.
出处
《中国标准化》
2017年第1X期236-,共1页
China Standardization
关键词
功率因数
无功补偿
电容器
power factor
reactive power compensation
capacitor