The subsection linear torsional model of hydrodynamic torque converter was established and further simplified. According to the identification theory, the frequency characteristic was achieved with the Matlab/ Ident ...The subsection linear torsional model of hydrodynamic torque converter was established and further simplified. According to the identification theory, the frequency characteristic was achieved with the Matlab/ Ident toolbox. Then parametric model was established by adopting the subsection linearization method, and the damp value was estimated. The curve and function of damp changing with speed ratio was also established by fitting. In order to validate the identification results, the experimental output was compared with the output of the model in which torque was chosen as input signal and speed as output signal in Matlab/Ident toolbox. It was shown that model output is in good agreement with experimental output.展开更多
For development of passenger electrical transport, it is necessary to use energy more rationally. One of methods of vehicle power efficiency increase is installation of on-board energy storage systems. For studying of...For development of passenger electrical transport, it is necessary to use energy more rationally. One of methods of vehicle power efficiency increase is installation of on-board energy storage systems. For studying of system operation, it is necessary to carry out a lot of experiments, therefore it is favorable to use the test bench and its computer model for reduction of the number of physical experiments. In this article, the results of computer modeling for the optimization of traction drive test bench by adjusting of the operation parameters of supercapacitor energy storage are described. Test bench operation is considered in cases of the energy storage system working at various selected supercapacitor initial voltages. Maximal increase of possibility of vehicle test bench regenerative braking with minimal decrease of autonomous power supply mode possibility is investigated. There is estimated the energy storage system efficiency improving measures dependence from supercapacitor operational voltage ranges. Parameters at which the minimum losses of energy are observed are revealed. Dependence of energy storage system discharge power on the most admissible supercapacitor current is established.展开更多
文摘The subsection linear torsional model of hydrodynamic torque converter was established and further simplified. According to the identification theory, the frequency characteristic was achieved with the Matlab/ Ident toolbox. Then parametric model was established by adopting the subsection linearization method, and the damp value was estimated. The curve and function of damp changing with speed ratio was also established by fitting. In order to validate the identification results, the experimental output was compared with the output of the model in which torque was chosen as input signal and speed as output signal in Matlab/Ident toolbox. It was shown that model output is in good agreement with experimental output.
文摘For development of passenger electrical transport, it is necessary to use energy more rationally. One of methods of vehicle power efficiency increase is installation of on-board energy storage systems. For studying of system operation, it is necessary to carry out a lot of experiments, therefore it is favorable to use the test bench and its computer model for reduction of the number of physical experiments. In this article, the results of computer modeling for the optimization of traction drive test bench by adjusting of the operation parameters of supercapacitor energy storage are described. Test bench operation is considered in cases of the energy storage system working at various selected supercapacitor initial voltages. Maximal increase of possibility of vehicle test bench regenerative braking with minimal decrease of autonomous power supply mode possibility is investigated. There is estimated the energy storage system efficiency improving measures dependence from supercapacitor operational voltage ranges. Parameters at which the minimum losses of energy are observed are revealed. Dependence of energy storage system discharge power on the most admissible supercapacitor current is established.