An edge Lyman-alpha-based beam emission spectroscopy(LyBES)diagnostic,using a heating NBI(neutral beam injection)system,is currently under development on the HL-2A tokamak.The 20-channel edge LyBES,which is intended t...An edge Lyman-alpha-based beam emission spectroscopy(LyBES)diagnostic,using a heating NBI(neutral beam injection)system,is currently under development on the HL-2A tokamak.The 20-channel edge LyBES,which is intended to measure the density fluctuation in plasma edge(from R=1960 mm to R=2026 mm)with an improved spatial resolution of 3.3 mm,is a complement to the existing conventional beam emission spectroscopy(BES)diagnostic.In this article,we introduce the progress of LyBES diagnostic,including the collection optics,the monochromator,and the detector system.The reflectance of the collection mirrors is measured to be~82%at 122 nm,and the aberration geometrical radius of the collection optics is tested to be~150μm in the aimed area.The linear dispersion of the LyBES monochromator is designed to be~0.09 nm mm^(-1).The bandwidth of the detector system with the 5×10^(7)V A^(-1)preamplifier gain is measured to be~280 kHz,and the peak-to-peak noise of the detector system is tested to be~16 mV.The finalized design,components development and testing of the LyBES diagnostic have been completed at present,and an overall performance of the LyBES diagnostic is to be confirmed in the next HL-2A campaign.展开更多
The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of tr...The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1).展开更多
Ultrafast charge exchange recombination spectroscopy(UF-CXRS)has been developed on the EAST tokamak(Yingying Li et al 2019 Fusion Eng.Des.146522)to measure fast evolutions of ion temperature and toroidal velocity.Here...Ultrafast charge exchange recombination spectroscopy(UF-CXRS)has been developed on the EAST tokamak(Yingying Li et al 2019 Fusion Eng.Des.146522)to measure fast evolutions of ion temperature and toroidal velocity.Here,we report the preliminary diagnostic measurements after relative sensitivity calibration.The measurement results show a much higher temporal resolution compared with conventional CXRS,benefiting from the usage of a prismcoupled,high-dispersion volume-phase holographic transmission grating and a high quantum efficiency,high-gain detector array.Utilizing the UF-CXRS diagnostic,the fast evolutions of the ion temperature and rotation velocity during a set of high-frequency small-amplitude edgelocalized modes(ELMs)are obtained on the EAST tokamak,which are then compared with the case of large-amplitude ELMs.展开更多
In this article,the design of a Lyman-alpha-based beam emission spectroscopy(LAB)diagnostic on the HL-2A tokamak has been proposed for the first time.The purpose of this novel diagnostic is to measure density fluctuat...In this article,the design of a Lyman-alpha-based beam emission spectroscopy(LAB)diagnostic on the HL-2A tokamak has been proposed for the first time.The purpose of this novel diagnostic is to measure density fluctuations of tokamak plasma.The light-collection system of LAB,which consists of the first mirror and two groups of coaxial double-mirror telescopes,can realize a twosegmented viewing field ofρ=0–0.2 andρ=0.75–1,which is optimized to measure plasma density fluctuation,not only in the edge transport barrier region but also in the internal transport barrier region,to investigate the underlying physics of turbulence in tokamaks.Spectrometers are developed to separate out the Doppler-shifted target line(122.03 and 122.17 nm)from the background Lyman-alpha line(121.53 nm).Here,30 Core-LAB channels and 30 Edge-LAB channels are under development on the HL-2A tokamak.It has high radial spatial resolutions of about 2.7 mm and 3.3 mm for the core and edge channels,respectively.Taking the high light intensity of this Lyman-alpha line into account,temporal resolution of 200 k Hz can be ensured by broad bandwidth amplifiers.This high spatio-temporal resolution makes LAB a potential keen tool to experimentally investigate tokamak plasma physics.展开更多
电荷交换复合光谱(Charge e Xchange Recombination Spectroscopy,CXRS)诊断系统主要用于等离子体旋转速度和离子温度的测量。CXRS诊断的另外一个重要应用是通过测量光谱的绝对强度来确定杂质离子的密度,因此需要对系统进行绝对强度标...电荷交换复合光谱(Charge e Xchange Recombination Spectroscopy,CXRS)诊断系统主要用于等离子体旋转速度和离子温度的测量。CXRS诊断的另外一个重要应用是通过测量光谱的绝对强度来确定杂质离子的密度,因此需要对系统进行绝对强度标定。在实验前通过精确校准过且各个波长强度已知的积分球光源对系统进行初步的标定;在实验过程中又利用托卡马克装置中等离子体自身产生的轫致辐射对系统的强度标定进行了进一步的检验。通过比较轫致辐射强度的实验测量值和理论计算值,可以发现两种方法得到的结果虽然存在一定的误差,但是它们的趋势是一致的。实验结果表明,利用轫致辐射进行绝对强度标定是可行的。展开更多
This paper presents the characteristics of L-mode detachment,together with the behavior of edge turbulent transport and plasma confinement on the HL-2A tokamak.Partially detached and pronounced detached states have be...This paper presents the characteristics of L-mode detachment,together with the behavior of edge turbulent transport and plasma confinement on the HL-2A tokamak.Partially detached and pronounced detached states have been achieved in L-mode plasma.Stored energy was maintained before and after detachment.Edge turbulence and its transport have increased obviously in the partially detached state.In the pronounced detached state,redistribution of the density and temperature profiles due to detachment leads to low amplitude of electron temperature and pressure,as well as very weak edge turbulence and transport.Despite strong plasma radiation in the pronounced detached state,reduced edge turbulent transport contributes to maintaining stored energy in detached L-mode plasma in HL-2A.Different detachment states play an important role in the redistribution of density and temperature profiles,which requires further study.展开更多
The impact of resonant magnetic perturbation(RMP)on blob motion and structure in the SOL of the HL-2A tokamak is studied using a gas puff imaging diagnostic.Ellipse fitting is applied to study the structure and motion...The impact of resonant magnetic perturbation(RMP)on blob motion and structure in the SOL of the HL-2A tokamak is studied using a gas puff imaging diagnostic.Ellipse fitting is applied to study the structure and motion of blobs quantitatively.The radial locations,amplitudes and scale sizes of blobs are obtained based on the fitted ellipse.Furthermore,based on the measurement of blob location,the radial and poloidal velocities of blobs are calculated.With the application of RMP,the edge poloidal shear flow is significantly weakened and the wave number spectrum changes from quasisymmetric to significantly up-down asymmetric.The application of RMP also causes the detected blob location to be much further into the far scrape-off layer(SOL)and increases the blob amplitude.Blob poloidal velocity in the SOL is slowed.Larger-size and longer-lifetime blobs are observed with RMP.With the application of RMP,stronger-amplitude and larger-size blobs are detected in the far SOL and they may cause a more serious erosion problem to the first wall.展开更多
A single-crystal diamond detector is fabricated to diagnose 14.1 MeV deuterium-tritium(D-T)fusion neutrons.The size of its diamond film is 4.5 mm×4.5 mm×500μm.This film is sandwiched by a flat,strip-pattern...A single-crystal diamond detector is fabricated to diagnose 14.1 MeV deuterium-tritium(D-T)fusion neutrons.The size of its diamond film is 4.5 mm×4.5 mm×500μm.This film is sandwiched by a flat,strip-patterned gold electrode.The dark current of this detector is experimentally measured to be lower than 0.1 nA under an electric field of 30 kV cm^(-1).This diamond detector is used to measure D-T fusion neutrons with a flux of about 7.5×10^(5) s^(-1)cm^(-2).The pronounced peak with a central energy of 8.28 MeV characterizing the^(12)C(n,α)~9Be reaction in the neutron energy spectrum is experimentally diagnosed,and the energy resolution is better than 1.69%,which is the best result reported so far using a diamond detector.A clear peak with a central energy of 6.52 MeV characterizing the^(12)C(n,n')3αreaction is also identified with an energy resolution of better than 7.67%.展开更多
Based on the single biasing electrode experiments to optimize the confinement of plasma in the device of KT-5C tokamak, dual-biasing electrodes were inserted into the KT5C plasma for the first time to explore the enha...Based on the single biasing electrode experiments to optimize the confinement of plasma in the device of KT-5C tokamak, dual-biasing electrodes were inserted into the KT5C plasma for the first time to explore the enhancing effects of biasing and the mechanisms of the biasing. By means of applying different combinations of biasing voltages onto the dual electrodes, the changes of Er, which are the key factor for boosting up the Er × B flow shear, were observed. The time evolution showed that the inner electrode played a major role in dual-biasing, which drew larger current than the outer one. The outer electrode produced little influence. It turned out that the dual-biasing electrodes were as effective as a single one in improving the plasma confinement, for the mechanism of biasing was essentially an edge effect.展开更多
基金supported by Sichuan Science and Technology Program(No.2022JDJQ0038)the National Key R&D Program of China(Nos.2022YFE03100002 and 2018YFE0303102)National Natural Science Foundation of China(Nos.12205087 and 12075241)。
文摘An edge Lyman-alpha-based beam emission spectroscopy(LyBES)diagnostic,using a heating NBI(neutral beam injection)system,is currently under development on the HL-2A tokamak.The 20-channel edge LyBES,which is intended to measure the density fluctuation in plasma edge(from R=1960 mm to R=2026 mm)with an improved spatial resolution of 3.3 mm,is a complement to the existing conventional beam emission spectroscopy(BES)diagnostic.In this article,we introduce the progress of LyBES diagnostic,including the collection optics,the monochromator,and the detector system.The reflectance of the collection mirrors is measured to be~82%at 122 nm,and the aberration geometrical radius of the collection optics is tested to be~150μm in the aimed area.The linear dispersion of the LyBES monochromator is designed to be~0.09 nm mm^(-1).The bandwidth of the detector system with the 5×10^(7)V A^(-1)preamplifier gain is measured to be~280 kHz,and the peak-to-peak noise of the detector system is tested to be~16 mV.The finalized design,components development and testing of the LyBES diagnostic have been completed at present,and an overall performance of the LyBES diagnostic is to be confirmed in the next HL-2A campaign.
基金supported by the National Key Research and Development Program of China(Nos.2019YFE03090100 and 2022YFE03100002)National Natural Science Foundation of China(No.12075241)。
文摘The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1).
基金supported by the National Magnetic Confinement Fusion Science Program of China (No. 2019YFE 03030004)National Natural Science Foundation of China (Nos. 11535013 and 11975232)
文摘Ultrafast charge exchange recombination spectroscopy(UF-CXRS)has been developed on the EAST tokamak(Yingying Li et al 2019 Fusion Eng.Des.146522)to measure fast evolutions of ion temperature and toroidal velocity.Here,we report the preliminary diagnostic measurements after relative sensitivity calibration.The measurement results show a much higher temporal resolution compared with conventional CXRS,benefiting from the usage of a prismcoupled,high-dispersion volume-phase holographic transmission grating and a high quantum efficiency,high-gain detector array.Utilizing the UF-CXRS diagnostic,the fast evolutions of the ion temperature and rotation velocity during a set of high-frequency small-amplitude edgelocalized modes(ELMs)are obtained on the EAST tokamak,which are then compared with the case of large-amplitude ELMs.
基金supported by the National Key R&D Program of China(Nos.2022YFE03100002,2017YFE0301201 and 2018YFE0303102)Sichuan Science and Technology Program(Nos.2022JDJQ0038 and 2020JDTD0030)National Natural Science Foundation of China(No.12205087)。
文摘In this article,the design of a Lyman-alpha-based beam emission spectroscopy(LAB)diagnostic on the HL-2A tokamak has been proposed for the first time.The purpose of this novel diagnostic is to measure density fluctuations of tokamak plasma.The light-collection system of LAB,which consists of the first mirror and two groups of coaxial double-mirror telescopes,can realize a twosegmented viewing field ofρ=0–0.2 andρ=0.75–1,which is optimized to measure plasma density fluctuation,not only in the edge transport barrier region but also in the internal transport barrier region,to investigate the underlying physics of turbulence in tokamaks.Spectrometers are developed to separate out the Doppler-shifted target line(122.03 and 122.17 nm)from the background Lyman-alpha line(121.53 nm).Here,30 Core-LAB channels and 30 Edge-LAB channels are under development on the HL-2A tokamak.It has high radial spatial resolutions of about 2.7 mm and 3.3 mm for the core and edge channels,respectively.Taking the high light intensity of this Lyman-alpha line into account,temporal resolution of 200 k Hz can be ensured by broad bandwidth amplifiers.This high spatio-temporal resolution makes LAB a potential keen tool to experimentally investigate tokamak plasma physics.
文摘电荷交换复合光谱(Charge e Xchange Recombination Spectroscopy,CXRS)诊断系统主要用于等离子体旋转速度和离子温度的测量。CXRS诊断的另外一个重要应用是通过测量光谱的绝对强度来确定杂质离子的密度,因此需要对系统进行绝对强度标定。在实验前通过精确校准过且各个波长强度已知的积分球光源对系统进行初步的标定;在实验过程中又利用托卡马克装置中等离子体自身产生的轫致辐射对系统的强度标定进行了进一步的检验。通过比较轫致辐射强度的实验测量值和理论计算值,可以发现两种方法得到的结果虽然存在一定的误差,但是它们的趋势是一致的。实验结果表明,利用轫致辐射进行绝对强度标定是可行的。
基金National Key Research and Development Program of China(Nos.2018YFE0303102,2018YFE0309103,2017YFE0300405 and 2017YFE0301203)National Natural Science Foundation of China(Nos.U1867222,11875124,11905051,11805055 and 11875020)Sichuan Youth Science and Technology Innovation Team Project(No.2020JDTD0030)。
文摘This paper presents the characteristics of L-mode detachment,together with the behavior of edge turbulent transport and plasma confinement on the HL-2A tokamak.Partially detached and pronounced detached states have been achieved in L-mode plasma.Stored energy was maintained before and after detachment.Edge turbulence and its transport have increased obviously in the partially detached state.In the pronounced detached state,redistribution of the density and temperature profiles due to detachment leads to low amplitude of electron temperature and pressure,as well as very weak edge turbulence and transport.Despite strong plasma radiation in the pronounced detached state,reduced edge turbulent transport contributes to maintaining stored energy in detached L-mode plasma in HL-2A.Different detachment states play an important role in the redistribution of density and temperature profiles,which requires further study.
基金supported by the National Key Research and Development Program of China(Nos.2022YFE03100002,2022YFE03010004 and 2019YFE03060002)National Natural Science Foundation of China(Nos.U1867222,U1967206 and 51821005)the Sichuan Natural Science Foundation(Nos.2022NSFSC1791 and 2020JDTD0030).
文摘The impact of resonant magnetic perturbation(RMP)on blob motion and structure in the SOL of the HL-2A tokamak is studied using a gas puff imaging diagnostic.Ellipse fitting is applied to study the structure and motion of blobs quantitatively.The radial locations,amplitudes and scale sizes of blobs are obtained based on the fitted ellipse.Furthermore,based on the measurement of blob location,the radial and poloidal velocities of blobs are calculated.With the application of RMP,the edge poloidal shear flow is significantly weakened and the wave number spectrum changes from quasisymmetric to significantly up-down asymmetric.The application of RMP also causes the detected blob location to be much further into the far scrape-off layer(SOL)and increases the blob amplitude.Blob poloidal velocity in the SOL is slowed.Larger-size and longer-lifetime blobs are observed with RMP.With the application of RMP,stronger-amplitude and larger-size blobs are detected in the far SOL and they may cause a more serious erosion problem to the first wall.
基金supported by National Natural Science Foundation of China(No.12075241)。
文摘A single-crystal diamond detector is fabricated to diagnose 14.1 MeV deuterium-tritium(D-T)fusion neutrons.The size of its diamond film is 4.5 mm×4.5 mm×500μm.This film is sandwiched by a flat,strip-patterned gold electrode.The dark current of this detector is experimentally measured to be lower than 0.1 nA under an electric field of 30 kV cm^(-1).This diamond detector is used to measure D-T fusion neutrons with a flux of about 7.5×10^(5) s^(-1)cm^(-2).The pronounced peak with a central energy of 8.28 MeV characterizing the^(12)C(n,α)~9Be reaction in the neutron energy spectrum is experimentally diagnosed,and the energy resolution is better than 1.69%,which is the best result reported so far using a diamond detector.A clear peak with a central energy of 6.52 MeV characterizing the^(12)C(n,n')3αreaction is also identified with an energy resolution of better than 7.67%.
基金supported by the Chinese Ministry of Education,the Chinese National Natural Science Foundation(Grant Nos.1023 5010 and 1033 5060)grants from the Chinese Academy of Sciences and by the JSPS-CAS Core University Program in the field of Plasma and Nuclear Fusion.
文摘Based on the single biasing electrode experiments to optimize the confinement of plasma in the device of KT-5C tokamak, dual-biasing electrodes were inserted into the KT5C plasma for the first time to explore the enhancing effects of biasing and the mechanisms of the biasing. By means of applying different combinations of biasing voltages onto the dual electrodes, the changes of Er, which are the key factor for boosting up the Er × B flow shear, were observed. The time evolution showed that the inner electrode played a major role in dual-biasing, which drew larger current than the outer one. The outer electrode produced little influence. It turned out that the dual-biasing electrodes were as effective as a single one in improving the plasma confinement, for the mechanism of biasing was essentially an edge effect.