A time-resolved sensitive He-Ne laser interferometer without complicated active stabilization was built up and applied to low-density plasma measurements. A precision of about 0.2° in phase measurements was achie...A time-resolved sensitive He-Ne laser interferometer without complicated active stabilization was built up and applied to low-density plasma measurements. A precision of about 0.2° in phase measurements was achieved with a minimum line-integrated plasma density as low as 8.3× 10^13 cm^-2. With this interferometer, the characteristics of the plasma generated by a cable plasma gun was investigated systematically. The reproducibility, spatial and temporal distributions and the averaged injection velocity of the plasma are presented. In addition, the interaction of the plasma flow with a conductor was studied by placing a metal plate in the downstream of the cable gun.展开更多
The rod-pinch diode(RPD)is a kind of new X-ray source for flash radiographic apphcations,especially in the small-scale hydrodynamic experiments.According to theoretical analysis and the generator parameters,the 1MV ro...The rod-pinch diode(RPD)is a kind of new X-ray source for flash radiographic apphcations,especially in the small-scale hydrodynamic experiments.According to theoretical analysis and the generator parameters,the 1MV rod pinch diode has been designed and studied experimentally.As a result,1.21 to 1.45rads at 1m in the forward direction (0°)are achieved in 18.1 to 27.5ns FWHM pulses,the spot sizes are 0.8 to 1.1mm with 1-mm-diameter tungsten rods. This suggests that the rod-pinch diode is a perfect X-ray source used in the small-scale hydrodynamic experiments.展开更多
文摘A time-resolved sensitive He-Ne laser interferometer without complicated active stabilization was built up and applied to low-density plasma measurements. A precision of about 0.2° in phase measurements was achieved with a minimum line-integrated plasma density as low as 8.3× 10^13 cm^-2. With this interferometer, the characteristics of the plasma generated by a cable plasma gun was investigated systematically. The reproducibility, spatial and temporal distributions and the averaged injection velocity of the plasma are presented. In addition, the interaction of the plasma flow with a conductor was studied by placing a metal plate in the downstream of the cable gun.
文摘The rod-pinch diode(RPD)is a kind of new X-ray source for flash radiographic apphcations,especially in the small-scale hydrodynamic experiments.According to theoretical analysis and the generator parameters,the 1MV rod pinch diode has been designed and studied experimentally.As a result,1.21 to 1.45rads at 1m in the forward direction (0°)are achieved in 18.1 to 27.5ns FWHM pulses,the spot sizes are 0.8 to 1.1mm with 1-mm-diameter tungsten rods. This suggests that the rod-pinch diode is a perfect X-ray source used in the small-scale hydrodynamic experiments.