A novel Hadamard transform(HT) microscopic image detection system which can generate 511× 512 pixel format images of fluorescence or absorptive light for small samples has been developed, when spatial multiplexin...A novel Hadamard transform(HT) microscopic image detection system which can generate 511× 512 pixel format images of fluorescence or absorptive light for small samples has been developed, when spatial multiplexing is performed with a 511 slit one dimensional Hadamard mask and a highly sensitive linear CCD. The weak native fluorescence imaging for Zephyranthes candida (Lindl.) Herb. Pollen cells can be realized within 1 min. The spatial resolution of 0 6 μm per pixel has been achieved with a 40× objective. The imaging speed, sensitivity and spatial resolution are satisfactory, hence the system has a good application prospect in cell biology and medicine. Some factors that influence imaging speed and quality have been discussed preliminarily.展开更多
The imaging capability(sensitivity, signal-to-noise ratio, imaging speed and spatial resolution) of a domestic-made high-resolution Hadamrd transform(HT) microscopic fluorescence imaging system was discussed. The resu...The imaging capability(sensitivity, signal-to-noise ratio, imaging speed and spatial resolution) of a domestic-made high-resolution Hadamrd transform(HT) microscopic fluorescence imaging system was discussed. The results show that the system can be applied for high-resolution single-cell imaging sensitively in a short time, the cell image provided by the system has a high-resolution up to 511×512 pixel. The results also shows that this system has a more excellent resolving power than conventional optical microscope, under a 100× objective(oil lens) the spatial resolution up to 0.24 μm per pixel in X direction was obtained, which is close to the resolution limit of conventional optical microscope. The system was used for multi-parameter evaluation of breast tumor malignancy and malignant grade for a single tumor cell based on nuclei DNA ploidy measurements, and satisfactory results were obtained.展开更多
文摘A novel Hadamard transform(HT) microscopic image detection system which can generate 511× 512 pixel format images of fluorescence or absorptive light for small samples has been developed, when spatial multiplexing is performed with a 511 slit one dimensional Hadamard mask and a highly sensitive linear CCD. The weak native fluorescence imaging for Zephyranthes candida (Lindl.) Herb. Pollen cells can be realized within 1 min. The spatial resolution of 0 6 μm per pixel has been achieved with a 40× objective. The imaging speed, sensitivity and spatial resolution are satisfactory, hence the system has a good application prospect in cell biology and medicine. Some factors that influence imaging speed and quality have been discussed preliminarily.
文摘The imaging capability(sensitivity, signal-to-noise ratio, imaging speed and spatial resolution) of a domestic-made high-resolution Hadamrd transform(HT) microscopic fluorescence imaging system was discussed. The results show that the system can be applied for high-resolution single-cell imaging sensitively in a short time, the cell image provided by the system has a high-resolution up to 511×512 pixel. The results also shows that this system has a more excellent resolving power than conventional optical microscope, under a 100× objective(oil lens) the spatial resolution up to 0.24 μm per pixel in X direction was obtained, which is close to the resolution limit of conventional optical microscope. The system was used for multi-parameter evaluation of breast tumor malignancy and malignant grade for a single tumor cell based on nuclei DNA ploidy measurements, and satisfactory results were obtained.