An E//B neutral particle analyzer(NPA)has been designed and is under development at Sichuan University and Southwestern Institute of Physics.The main purpose of the E//B NPA is to measure the distribution function of ...An E//B neutral particle analyzer(NPA)has been designed and is under development at Sichuan University and Southwestern Institute of Physics.The main purpose of the E//B NPA is to measure the distribution function of fast ions in the HL-2A/3 tokamak.The E//B NPA contains three main units,i.e.the stripping unit,the analyzing unit and the detection unit.A gas stripping chamber was adopted as the stripping unit.The results of the simulations and beam tests for the stripping chamber are presented.Parallel electric and magnetic fields provided by a NdFeB permanent magnet and two parallel electric plates were designed and constructed for the analyzing unit.The calibration of the magnetic and electric fields was performed using a 50 kV electron cyclotron resonance ion source(ECRIS)platform.The detection unit consists of 32lutetium-yttrium oxyorthosilicate(LYSO)detector modules arranged in two rows.The response functions ofα,hydrogen ions(H^(+),H_(2)^(+)and H_(3)^(+))andγfor a detector module were measured with^(241)Am,^(137)Cs and^(152)Eu sources together with the 50 kV ECRIS platform.The overall results indicate that the designed E//B NPA device is capable of measuring the intensity of neutral hydrogen and deuteron atoms with energy higher than 20 keV.展开更多
The interaction of MeV H2^+ molecular ions with thin layer graphene and graphite foils was studied by using a highresolution electrostatic analyzer.A large number of fragment protons were observed at zero degree(along...The interaction of MeV H2^+ molecular ions with thin layer graphene and graphite foils was studied by using a highresolution electrostatic analyzer.A large number of fragment protons were observed at zero degree(along the beam direction) when the H2^+ beam was passing through the monolayer graphene foil, which indicates that the electron of the H2^+ molecular ions can be stripped easily even by the monolayer graphene foil.More trailing than leading protons were found in the energy spectrum, which means significant wake effect was observed in the monolayer graphene foil.The ratio of the numbers of trailing protons over leading protons first increased with the thickness for the much thinner graphene foils, and then decreased with the thickness for the much thicker graphite foils, which indicates that the bending effect of the wake field on the trailing proton varied with the foil thickness.展开更多
The interaction between the supersonic molecular beam(SMB)and the low-temperature plasma is a critical issue for the diagnosis and fueling in the Tokamak device.In this work,the interaction process between the argon S...The interaction between the supersonic molecular beam(SMB)and the low-temperature plasma is a critical issue for the diagnosis and fueling in the Tokamak device.In this work,the interaction process between the argon SMB and the argon plasma is studied by a high-speed camera based on the Linear Experimental Advanced Device(LEAD)in Southwestern Institute of Physics,China.It is found that the high-density SMB can extinct the plasma temporarily and change the distribution of the plasma density significantly,while the low-density SMB can hardly affect the distribution of plasma density.This can be used as an effective diagnostic technique to study the evolution of plasma density in the interaction between the SMB and plasma.Moreover,the related simulation based on this experiment is carried out to better understand the evolution of electron density and ion density in the interaction.The simulation results can be used to analyze and explain the experimental results well.展开更多
基金supported by the National Magnetic Confinement Fusion Energy R&D Program of China(No.2018YFE0310200)National Natural Science Foundation of China(Nos.11705242,11805138 and 12175156)the Fundamental Research Funds for the Central Universities in China(Nos.YJ201820 and YJ201954)。
文摘An E//B neutral particle analyzer(NPA)has been designed and is under development at Sichuan University and Southwestern Institute of Physics.The main purpose of the E//B NPA is to measure the distribution function of fast ions in the HL-2A/3 tokamak.The E//B NPA contains three main units,i.e.the stripping unit,the analyzing unit and the detection unit.A gas stripping chamber was adopted as the stripping unit.The results of the simulations and beam tests for the stripping chamber are presented.Parallel electric and magnetic fields provided by a NdFeB permanent magnet and two parallel electric plates were designed and constructed for the analyzing unit.The calibration of the magnetic and electric fields was performed using a 50 kV electron cyclotron resonance ion source(ECRIS)platform.The detection unit consists of 32lutetium-yttrium oxyorthosilicate(LYSO)detector modules arranged in two rows.The response functions ofα,hydrogen ions(H^(+),H_(2)^(+)and H_(3)^(+))andγfor a detector module were measured with^(241)Am,^(137)Cs and^(152)Eu sources together with the 50 kV ECRIS platform.The overall results indicate that the designed E//B NPA device is capable of measuring the intensity of neutral hydrogen and deuteron atoms with energy higher than 20 keV.
基金Project supported by the National Natural Science Foundation of China(Grant No.11575121)the National Magnetic Confinement Fusion Program of China(Grant No.2014GB125004)
文摘The interaction of MeV H2^+ molecular ions with thin layer graphene and graphite foils was studied by using a highresolution electrostatic analyzer.A large number of fragment protons were observed at zero degree(along the beam direction) when the H2^+ beam was passing through the monolayer graphene foil, which indicates that the electron of the H2^+ molecular ions can be stripped easily even by the monolayer graphene foil.More trailing than leading protons were found in the energy spectrum, which means significant wake effect was observed in the monolayer graphene foil.The ratio of the numbers of trailing protons over leading protons first increased with the thickness for the much thinner graphene foils, and then decreased with the thickness for the much thicker graphite foils, which indicates that the bending effect of the wake field on the trailing proton varied with the foil thickness.
基金National Natural Science Foundation of China(Grant Nos.11575121,11275133,and 11575055)the National Magnetic Confinement Fusion Program of China(Grant No.2014GB125004).
文摘The interaction between the supersonic molecular beam(SMB)and the low-temperature plasma is a critical issue for the diagnosis and fueling in the Tokamak device.In this work,the interaction process between the argon SMB and the argon plasma is studied by a high-speed camera based on the Linear Experimental Advanced Device(LEAD)in Southwestern Institute of Physics,China.It is found that the high-density SMB can extinct the plasma temporarily and change the distribution of the plasma density significantly,while the low-density SMB can hardly affect the distribution of plasma density.This can be used as an effective diagnostic technique to study the evolution of plasma density in the interaction between the SMB and plasma.Moreover,the related simulation based on this experiment is carried out to better understand the evolution of electron density and ion density in the interaction.The simulation results can be used to analyze and explain the experimental results well.