This paper presents the optimization cycle of the EAST cryogenic system. A simulation analysis and simulation of the main Claude program of this cycle was developed on the basis of the characteristics of the component...This paper presents the optimization cycle of the EAST cryogenic system. A simulation analysis and simulation of the main Claude program of this cycle was developed on the basis of the characteristics of the components and verified with the experimental results. The built-in volume ratio of the No. 7 compressor was tested with the purpose of finding the optimum internal pressure ratio to comply with the external pressure ratio so as to increase the isothermal efficiency and cycle efficiency. In addition, the UA (U, heat transfer coefficient; A, heat transfer area) values of the heat exchangers, efficiencies of turbines, mass flow fraction of the turbine stream were analyzed in order to improve the capacity or efficiency of the cycle. Finally, in view of the estimated heat loads of EAST in future, an upgraded operational cycle of 1500 W/4.5 K +1000 W/3.5 K +5 g/s is proposed according to the simulation.展开更多
In this paper,the process modeling and dynamic simulation for the EAST helium refrigerator has been completed.The cryogenic process model is described and the main components are customized in detail.The process model...In this paper,the process modeling and dynamic simulation for the EAST helium refrigerator has been completed.The cryogenic process model is described and the main components are customized in detail.The process model is controlled by the PLC simulator,and the realtime communication between the process model and the controllers is achieved by a customized interface.Validation of the process model has been confirmed based on EAST experimental data during the cool down process of 300-80 K.Simulation results indicate that this process simulator is able to reproduce dynamic behaviors of the EAST helium refrigerator very well for the operation of long pulsed plasma discharge.The cryogenic process simulator based on control architecture is available for operation optimization and control design of EAST cryogenic systems to cope with the long pulsed heat loads in the future.展开更多
基金supported by the Knowledge Innovation Program of the Chinese Academy of Sciences
文摘This paper presents the optimization cycle of the EAST cryogenic system. A simulation analysis and simulation of the main Claude program of this cycle was developed on the basis of the characteristics of the components and verified with the experimental results. The built-in volume ratio of the No. 7 compressor was tested with the purpose of finding the optimum internal pressure ratio to comply with the external pressure ratio so as to increase the isothermal efficiency and cycle efficiency. In addition, the UA (U, heat transfer coefficient; A, heat transfer area) values of the heat exchangers, efficiencies of turbines, mass flow fraction of the turbine stream were analyzed in order to improve the capacity or efficiency of the cycle. Finally, in view of the estimated heat loads of EAST in future, an upgraded operational cycle of 1500 W/4.5 K +1000 W/3.5 K +5 g/s is proposed according to the simulation.
基金supported by National Natural Science Foundation of China(No.51306195)Key Laboratory of Cryogenics,Technical Institute of Physics and Chemistry,CAS(No.CRYO201408)
文摘In this paper,the process modeling and dynamic simulation for the EAST helium refrigerator has been completed.The cryogenic process model is described and the main components are customized in detail.The process model is controlled by the PLC simulator,and the realtime communication between the process model and the controllers is achieved by a customized interface.Validation of the process model has been confirmed based on EAST experimental data during the cool down process of 300-80 K.Simulation results indicate that this process simulator is able to reproduce dynamic behaviors of the EAST helium refrigerator very well for the operation of long pulsed plasma discharge.The cryogenic process simulator based on control architecture is available for operation optimization and control design of EAST cryogenic systems to cope with the long pulsed heat loads in the future.