期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Additively manufactured Ti–Ta–Cu alloys for the next-generation load-bearing implants 被引量:1
1
作者 amit bandyopadhyay Indranath Mitra +4 位作者 Sushant Ciliveri Jose D Avila William Dernell Stuart B Goodman Susmita Bose 《International Journal of Extreme Manufacturing》 SCIE EI CAS CSCD 2024年第1期353-374,共22页
Bacterial colonization of orthopedic implants is one of the leading causes of failure and clinical complexities for load-bearing metallic implants. Topical or systemic administration of antibiotics may not offer the m... Bacterial colonization of orthopedic implants is one of the leading causes of failure and clinical complexities for load-bearing metallic implants. Topical or systemic administration of antibiotics may not offer the most efficient defense against colonization, especially in the case of secondary infection, leading to surgical removal of implants and in some cases even limbs. In this study, laser powder bed fusion was implemented to fabricate Ti3Al2V alloy by a 1:1 weight mixture of CpTi and Ti6Al4V powders. Ti-Tantalum(Ta)–Copper(Cu) alloys were further analyzed by the addition of Ta and Cu into the Ti3Al2V custom alloy. The biological,mechanical, and tribo-biocorrosion properties of Ti3Al2V alloy were evaluated. A 10 wt.% Ta(10Ta) and 3 wt.% Cu(3Cu) were added to the Ti3Al2V alloy to enhance biocompatibility and impart inherent bacterial resistance. Additively manufactured implants were investigated for resistance against Pseudomonas aeruginosa and Staphylococcus aureus strains of bacteria for up to 48 h. A 3 wt.% Cu addition to Ti3Al2V displayed improved antibacterial efficacy, i.e.78%–86% with respect to CpTi. Mechanical properties for Ti3Al2V–10Ta–3Cu alloy were evaluated, demonstrating excellent fatigue resistance, exceptional shear strength, and improved tribological and tribo-biocorrosion characteristics when compared to Ti6Al4V. In vivo studies using a rat distal femur model revealed improved early-stage osseointegration for alloys with10 wt.% Ta addition compared to CpTi and Ti6Al4V. The 3 wt.% Cu-added compositions displayed biocompatibility and no adverse infammatory response in vivo. Our results establish the Ti3Al2V–10Ta–3Cu alloy’s synergistic effect on improving both in vivo biocompatibility and microbial resistance for the next generation of load-bearing metallic implants. 展开更多
关键词 TI6AL4V load-bearing implants additive manufacturing 3D printing antibacterial performance
下载PDF
Printability disparities in heterogeneous material combinations via laser directed energy deposition:a comparative study 被引量:1
2
作者 Jinsheng Ning Lida Zhu +9 位作者 Shuhao Wang Zhichao Yang Peihua Xu Pengsheng Xue Hao Lu Miao Yu Yunhang Zhao Jiachen Li Susmita Bose amit bandyopadhyay 《International Journal of Extreme Manufacturing》 SCIE EI CAS CSCD 2024年第2期389-405,共17页
Additive manufacturing provides achievability for the fabrication of bimetallic and multi-material structures;however,the material compatibility and bondability directly affect the parts’formability and final quality... Additive manufacturing provides achievability for the fabrication of bimetallic and multi-material structures;however,the material compatibility and bondability directly affect the parts’formability and final quality.It is essential to understand the underlying printability of different material combinations based on an adapted process.Here,the printability disparities of two common and attractive material combinations(nickel-and iron-based alloys)are evaluated at the macro and micro levels via laser directed energy deposition(DED).The deposition processes were captured using in situ high-speed imaging,and the dissimilarities in melt pool features and track morphology were quantitatively investigated within specific process windows.Moreover,the microstructure diversity of the tracks and blocks processed with varied material pairs was comparatively elaborated and,complemented with the informative multi-physics modeling,the presented non-uniformity in mechanical properties(microhardness)among the heterogeneous material pairs was rationalized.The differences in melt flow induced by the unlike thermophysical properties of the material pairs and the resulting element intermixing and localized re-alloying during solidification dominate the presented dissimilarity in printability among the material combinations.This work provides an in-depth understanding of the phenomenological differences in the deposition of dissimilar materials and aims to guide more reliable DED forming of bimetallic parts. 展开更多
关键词 directed energy deposition PRINTABILITY microstructure MICROHARDNESS bimetallic parts
下载PDF
Functionally graded structure of a nitride-strengthened Mg_(2)Si-based hybrid composite
3
作者 Jeongho Yang Woongbeom Heogh +15 位作者 Hogi Ju Sukhyun Kang Tae-Sik Jang Hyun-Do Jung Mohammad Jahazi Seung Chul Han Seong Je Park Hyoung Seop Kim Susmita Bose amit bandyopadhyay Martin Byung-Guk Jun Young Won Kim Dae-kyeom Kim Rigoberto CAdvincula Clodualdo Aranas Jr Sang Hoon Kim 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第3期1239-1256,共18页
The ex-situ incorporation of the secondary SiC reinforcement,along with the in-situ incorporation of the tertiary and quaternary Mg_(3)N_(2) and Si_(3)N_(4) phases,in the primary matrix of Mg_(2)Si is employed in orde... The ex-situ incorporation of the secondary SiC reinforcement,along with the in-situ incorporation of the tertiary and quaternary Mg_(3)N_(2) and Si_(3)N_(4) phases,in the primary matrix of Mg_(2)Si is employed in order to provide ultimate wear resistance based on the laser-irradiation-induced inclusion of N_(2) gas during laser powder bed fusion.This is substantialized based on both the thermal diffusion-and chemical reactionbased metallurgy of the Mg_(2)Si–SiC/nitride hybrid composite.This study also proposes a functional platform for systematically modulating a functionally graded structure and modeling build-direction-dependent architectonics during additive manufacturing.This strategy enables the development of a compositional gradient from the center to the edge of each melt pool of the Mg_(2)Si–SiC/nitride hybrid composite.Consequently,the coefficient of friction of the hybrid composite exhibits a 309.3%decrease to–1.67 compared to–0.54 for the conventional nonreinforced Mg_(2)Si structure,while the tensile strength exhibits a 171.3%increase to 831.5 MPa compared to 485.3 MPa for the conventional structure.This outstanding mechanical behavior is due to the(1)the complementary and synergistic reinforcement effects of the SiC and nitride compounds,each of which possesses an intrinsically high hardness,and(2)the strong adhesion of these compounds to the Mg_(2)Si matrix despite their small sizes and low concentrations. 展开更多
关键词 Laser powder bed fusion Mg_(2)Si-SiC/nitride hybrid composite Both the thermal diffusion-and chemical reaction-based metallurgy Functionally graded structure Compositional gradient Wear resistance.
下载PDF
Porous metal implants: processing,properties, and challenges 被引量:8
4
作者 amit bandyopadhyay Indranath Mitra +2 位作者 Jose D Avila Mahadev Upadhyayula Susmita Bose 《International Journal of Extreme Manufacturing》 SCIE EI CAS CSCD 2023年第3期441-483,共43页
Porous and functionally graded materials have seen extensive applications in modern biomedical devices—allowing for improved site-specific performance;their appreciable mechanical,corrosive,and biocompatible properti... Porous and functionally graded materials have seen extensive applications in modern biomedical devices—allowing for improved site-specific performance;their appreciable mechanical,corrosive,and biocompatible properties are highly sought after for lightweight and high-strength load-bearing orthopedic and dental implants.Examples of such porous materials are metals,ceramics,and polymers.Although,easy to manufacture and lightweight,porous polymers do not inherently exhibit the required mechanical strength for hard tissue repair or replacement.Alternatively,porous ceramics are brittle and do not possess the required fatigue resistance.On the other hand,porous biocompatible metals have shown tailorable strength,fatigue resistance,and toughness.Thereby,a significant interest in investigating the manufacturing challenges of porous metals has taken place in recent years.Past research has shown that once the advantages of porous metallic structures in the orthopedic implant industry have been realized,their biological and biomechanical compatibility—with the host bone—has been followed up with extensive methodical research.Various manufacturing methods for porous or functionally graded metals are discussed and compared in this review,specifically,how the manufacturing process influences microstructure,graded composition,porosity,biocompatibility,and mechanical properties.Most of the studies discussed in this review are related to porous structures for bone implant applications;however,the understanding of these investigations may also be extended to other devices beyond the biomedical field. 展开更多
关键词 porous metals load-bearing implants 3d printing additive manufacturing mechanical properties biological properties
下载PDF
Vitamin C and E supplementation and high intensity interval training induced changes in lipid profile and haematological variables of young males
5
作者 Surojit Sarkar Swapan Kr Dey +1 位作者 Gouriprosad Datta amit bandyopadhyay 《Sports Medicine and Health Science》 2023年第2期137-145,共9页
High intensity interval training(HIIT)causes oxidative stress and haematological alteration.Present study was aimed to evaluate the effect of 8 weeks’supplementation of vitamin C and E on HIIT induced changes in lipi... High intensity interval training(HIIT)causes oxidative stress and haematological alteration.Present study was aimed to evaluate the effect of 8 weeks’supplementation of vitamin C and E on HIIT induced changes in lipid profile parameters and haematological variables.Hundred six male adolescent players were randomly assigned into five age-matched groups,i.e.,Control(no exercise+placebo),HIIT(placebo),HIIT+vitamin-C(1000mg/day),HIIT+vitamin-E 400 IU/day)and combined HIIT+vitamin C and E.Morning and evening sessions(90min)of HIIT included 4 phases(15min each)with 3 sets(4min each).Each 4min HIIT set consisted of 2min intense sprint workout(90%–95%of heart rate maximum[HRmax])followed by 1min active recovery(60%–70%HRmax)followed by 1min of complete rest(1:1 work-rest ratio).Lipid profile parameters,haematological variables,endurance capacity and vertical jump were evaluated by standard protocols.Significant decrease in body weight,fat%,total cholesterol,triglyceride,Total Cholesterol/High Density Lipoprotein-Cholesterol and significant increase in High Density Lipoprotein-Cholesterol,maximal oxygen consumption,vertical jump were observed for all four intervention groups.White blood cell count,red blood cell count,haemoglobin percentage and haematocrit values were significantly decreased while platelet count and platelet-to-leukocyte ratio(PLR)ratio were increased significantly only for HIIT group.Blood level of tocopherol and ascorbic acid was significantly increased(values were within the normal range)in all the respective vitamin supplemented groups.Supplementation of vitamin C and E secures health protection with suppressed haemolysis and improved inflammatory blood variables with enhanced explosive leg strength and lipid profile parameters without any concomitant change in endurance capacity. 展开更多
关键词 Sprint interval training Lipid profile Haematological indices HAEMOLYSIS ATHLETES
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部