This paper deals with power quality improvement using a three-phase active power filter(APF) connected to a PV power system. A direct power control(DPC) approach is proposed to eliminate harmonic current caused by any...This paper deals with power quality improvement using a three-phase active power filter(APF) connected to a PV power system. A direct power control(DPC) approach is proposed to eliminate harmonic current caused by any nonlinear loads and at the same time guarantees the delivery of a part of the load request from the same PV source. A boost converter is used for maximum power point(MPP) tracking purposes under various climate conditions through a fuzzy logic technique. The suggested study is tested under a MATLAB/Simulink environment. The obtained results depict the efficacy of the proposed procedures to meet the IEEE 519-1992 standard recommendation on harmonic levels.展开更多
Solar photovoltaic(PV)power represents one of the most promising future sources of energy in the world.Considered the cleanest form of energy,extensive research is being undertaken to widen its use.Notably,mega projec...Solar photovoltaic(PV)power represents one of the most promising future sources of energy in the world.Considered the cleanest form of energy,extensive research is being undertaken to widen its use.Notably,mega projects are being considered for installation in the Middle East and North Africa(MENA)region because of its high solar potential,with hopes of eventually feeding Europe from the PV electricity generated in this region and transported through high voltage direct current(DC)lines.However,current implementation of PV systems has shown that their reliability and efficiency depend upon surrounding environmental factors,such as the ambient temperature,wind,and rainfall,as well as soiling,pollution,and aging.The aim of this study was to investigate,through experimental tests,the effects of such factors on the power output of a grid connected PV station.The results showed that the output power and efficiency are deeply affected by various environmental factors,which are weather dependent.These findings may help us develop appropriate solutions to overcome these drawbacks.展开更多
In this paper, a five-level inverter is used as a shunt active power filter (APF), taking advantages of the multilevel inverter such as low harmonic distortion and reduced switching losses. It is used to compensate ...In this paper, a five-level inverter is used as a shunt active power filter (APF), taking advantages of the multilevel inverter such as low harmonic distortion and reduced switching losses. It is used to compensate reactive power and eliminate harmonics drawn from a thyristor rectifier feeding an inductive load (RL) under distorted voltage conditions. The APF control strategy is based on the use of self-tuning filters (STF) for reference current generation and a fuzzy logic current controller. The use of STF instead of classical extraction filters allows extracting directly the voltage and current fundamental components in the a-fl axis without phase locked loop (PLL). The MATLAB fuzzy logic toolbox is used for implementing the fitzzy logic control algorithm. The obtained results show that the proposed shunt APF controller has produced a sinusoidal supply current with low harmonic distortion and in phase with the line voltage.展开更多
This paper introduces a technique based on linear quadratic regulator (LQR) to control the output voltage at the load point versus load variation from a stand- alone proton exchange membrane (PEM) fuel cell power ...This paper introduces a technique based on linear quadratic regulator (LQR) to control the output voltage at the load point versus load variation from a stand- alone proton exchange membrane (PEM) fuel cell power plant (FCPP) for a group housing use. The controller modifies the optimal gains ki by minimizing a cost function, and the phase angle of the AC output voltage to control the active and reactive power output from an FCPP to match the terminal load. The control actions are based on feedback signals from the terminal load, output voltage and fuel cell feedback current. The topology chosen for the simulation consists of a 45 kW proton exchange membrane fuel cell (PEMFC), boost type DC/ DC converter, a three-phase DC/AC inverter followed by an LC filter. Simulation results show that the proposed control strategy operated at low commutation frequency (2 kHz) offers good performances versus load variations with low total harmonic distortions (THD), which is very useful for high power applications.展开更多
文摘This paper deals with power quality improvement using a three-phase active power filter(APF) connected to a PV power system. A direct power control(DPC) approach is proposed to eliminate harmonic current caused by any nonlinear loads and at the same time guarantees the delivery of a part of the load request from the same PV source. A boost converter is used for maximum power point(MPP) tracking purposes under various climate conditions through a fuzzy logic technique. The suggested study is tested under a MATLAB/Simulink environment. The obtained results depict the efficacy of the proposed procedures to meet the IEEE 519-1992 standard recommendation on harmonic levels.
文摘Solar photovoltaic(PV)power represents one of the most promising future sources of energy in the world.Considered the cleanest form of energy,extensive research is being undertaken to widen its use.Notably,mega projects are being considered for installation in the Middle East and North Africa(MENA)region because of its high solar potential,with hopes of eventually feeding Europe from the PV electricity generated in this region and transported through high voltage direct current(DC)lines.However,current implementation of PV systems has shown that their reliability and efficiency depend upon surrounding environmental factors,such as the ambient temperature,wind,and rainfall,as well as soiling,pollution,and aging.The aim of this study was to investigate,through experimental tests,the effects of such factors on the power output of a grid connected PV station.The results showed that the output power and efficiency are deeply affected by various environmental factors,which are weather dependent.These findings may help us develop appropriate solutions to overcome these drawbacks.
文摘In this paper, a five-level inverter is used as a shunt active power filter (APF), taking advantages of the multilevel inverter such as low harmonic distortion and reduced switching losses. It is used to compensate reactive power and eliminate harmonics drawn from a thyristor rectifier feeding an inductive load (RL) under distorted voltage conditions. The APF control strategy is based on the use of self-tuning filters (STF) for reference current generation and a fuzzy logic current controller. The use of STF instead of classical extraction filters allows extracting directly the voltage and current fundamental components in the a-fl axis without phase locked loop (PLL). The MATLAB fuzzy logic toolbox is used for implementing the fitzzy logic control algorithm. The obtained results show that the proposed shunt APF controller has produced a sinusoidal supply current with low harmonic distortion and in phase with the line voltage.
文摘This paper introduces a technique based on linear quadratic regulator (LQR) to control the output voltage at the load point versus load variation from a stand- alone proton exchange membrane (PEM) fuel cell power plant (FCPP) for a group housing use. The controller modifies the optimal gains ki by minimizing a cost function, and the phase angle of the AC output voltage to control the active and reactive power output from an FCPP to match the terminal load. The control actions are based on feedback signals from the terminal load, output voltage and fuel cell feedback current. The topology chosen for the simulation consists of a 45 kW proton exchange membrane fuel cell (PEMFC), boost type DC/ DC converter, a three-phase DC/AC inverter followed by an LC filter. Simulation results show that the proposed control strategy operated at low commutation frequency (2 kHz) offers good performances versus load variations with low total harmonic distortions (THD), which is very useful for high power applications.