Theoretical calculations have been carried out to investigate the possible dissociation channels of isoprene. We focus on the major fragment ions of C5H7+, C5H5+, C4H5+, C3H6+, C3H5+, C3H4+, C3H3+ and C2H3+, w...Theoretical calculations have been carried out to investigate the possible dissociation channels of isoprene. We focus on the major fragment ions of C5H7+, C5H5+, C4H5+, C3H6+, C3H5+, C3H4+, C3H3+ and C2H3+, which were observed experimentally from the isoprene dissociative photoionization. The energy calculations were performed with the CBS-QB3 model. All the geometries and energies of the fragments, intermediates and transition states involved in the dissociations channels were determined. Finally, the mechanisms of the dissociation pathways were discussed on the comparison of theoretical and experimental results.展开更多
This work is devoted to experimentally study the characteristics of discharge plasma in high power xenon flashlamps.In the experiments,plasma channel profiles are captured by using a high speed CCD camera,and the radi...This work is devoted to experimentally study the characteristics of discharge plasma in high power xenon flashlamps.In the experiments,plasma channel profiles are captured by using a high speed CCD camera,and the radiation energy of the flashlamp is obtained by a pyroelectric energy meter.Voltage and current curves are recorded to shed light on the plasma characteristics.With these diagnostic methods,typical factors influencing the evolution process of plasma channel are studied,including the external electric field and the pre-ionization.The electric potential distribution in the flashlamp influence the plasma channel characteristics the most significantly.The plasma channel pattern for the cases with grounded wires is different from that with ungrounded metal wires.When the wire is ungrounded,it is the coupling voltage between the metal wire and the flashlamp that influences the development of plasma channel.In terms of radiation efficiency,it is proven that there is an optimal interval within 200~300μs between the pre-ionization pulse and the main pulse.展开更多
The precision of results obtained from the ^109Cd K XRF in vivo measurement system of bone lead for obses subjects with high BMI( body mass index)was poor.The main factor affecting the precision was the distance betwe...The precision of results obtained from the ^109Cd K XRF in vivo measurement system of bone lead for obses subjects with high BMI( body mass index)was poor.The main factor affecting the precision was the distance between tibia and detector.Compared with the standard phantom,a large phantom was used to simulate the obese subject in the measurements at different distances to the detector.The counts of Compton scattering increased highly because of the tissue overlying and surrounding tibia of the obese subject.When the distance between leg and detector was too small,the instrument would produce the distorted X-ray spectra,so that the obtained data were inaccurate,In order to ensure good measuremtn precision and accuracy,the distance between leg and detector should be maintained at 25mm during the counting period.Meanwhile,the dead time displayed instantly on the instrument should be controlled to around 30%.展开更多
Bloodletting therapy, as an ancient medical technology, has been applied around the world for thousands of years. In Arab region, bloodletting therapy is called Al-Hijamah which is analogous to the bloodletting and cu...Bloodletting therapy, as an ancient medical technology, has been applied around the world for thousands of years. In Arab region, bloodletting therapy is called Al-Hijamah which is analogous to the bloodletting and cupping in traditional Chinese medicine. However, Al-Hijamah therapy has its own characteristics which are analyzed emphatically in this report, including strict operating procedure, prominent mental effect, emphasis on bloodletting time, extensive indications, definite contraindications and so forth.展开更多
基金This work was supported by the National Natural Science Foundation of China (No.91544228, No.21307137, No.41575125, No.41375127, No.U1232209) and the Outstanding Youth Science Foundation of Fujian Province of China (No.2015J06009).
文摘Theoretical calculations have been carried out to investigate the possible dissociation channels of isoprene. We focus on the major fragment ions of C5H7+, C5H5+, C4H5+, C3H6+, C3H5+, C3H4+, C3H3+ and C2H3+, which were observed experimentally from the isoprene dissociative photoionization. The energy calculations were performed with the CBS-QB3 model. All the geometries and energies of the fragments, intermediates and transition states involved in the dissociations channels were determined. Finally, the mechanisms of the dissociation pathways were discussed on the comparison of theoretical and experimental results.
文摘This work is devoted to experimentally study the characteristics of discharge plasma in high power xenon flashlamps.In the experiments,plasma channel profiles are captured by using a high speed CCD camera,and the radiation energy of the flashlamp is obtained by a pyroelectric energy meter.Voltage and current curves are recorded to shed light on the plasma characteristics.With these diagnostic methods,typical factors influencing the evolution process of plasma channel are studied,including the external electric field and the pre-ionization.The electric potential distribution in the flashlamp influence the plasma channel characteristics the most significantly.The plasma channel pattern for the cases with grounded wires is different from that with ungrounded metal wires.When the wire is ungrounded,it is the coupling voltage between the metal wire and the flashlamp that influences the development of plasma channel.In terms of radiation efficiency,it is proven that there is an optimal interval within 200~300μs between the pre-ionization pulse and the main pulse.
文摘The precision of results obtained from the ^109Cd K XRF in vivo measurement system of bone lead for obses subjects with high BMI( body mass index)was poor.The main factor affecting the precision was the distance between tibia and detector.Compared with the standard phantom,a large phantom was used to simulate the obese subject in the measurements at different distances to the detector.The counts of Compton scattering increased highly because of the tissue overlying and surrounding tibia of the obese subject.When the distance between leg and detector was too small,the instrument would produce the distorted X-ray spectra,so that the obtained data were inaccurate,In order to ensure good measuremtn precision and accuracy,the distance between leg and detector should be maintained at 25mm during the counting period.Meanwhile,the dead time displayed instantly on the instrument should be controlled to around 30%.
文摘Bloodletting therapy, as an ancient medical technology, has been applied around the world for thousands of years. In Arab region, bloodletting therapy is called Al-Hijamah which is analogous to the bloodletting and cupping in traditional Chinese medicine. However, Al-Hijamah therapy has its own characteristics which are analyzed emphatically in this report, including strict operating procedure, prominent mental effect, emphasis on bloodletting time, extensive indications, definite contraindications and so forth.