The precision of results obtained from the ^109Cd K XRF in vivo measurement system of bone lead for obses subjects with high BMI( body mass index)was poor.The main factor affecting the precision was the distance betwe...The precision of results obtained from the ^109Cd K XRF in vivo measurement system of bone lead for obses subjects with high BMI( body mass index)was poor.The main factor affecting the precision was the distance between tibia and detector.Compared with the standard phantom,a large phantom was used to simulate the obese subject in the measurements at different distances to the detector.The counts of Compton scattering increased highly because of the tissue overlying and surrounding tibia of the obese subject.When the distance between leg and detector was too small,the instrument would produce the distorted X-ray spectra,so that the obtained data were inaccurate,In order to ensure good measuremtn precision and accuracy,the distance between leg and detector should be maintained at 25mm during the counting period.Meanwhile,the dead time displayed instantly on the instrument should be controlled to around 30%.展开更多
The Hong Kong-Kowloon Block,which has been uplifted continually and is stable since the late Cretaceous-Paleogene period,is identified and determined as a potential source with a maximum credible magnitude of M=5.5,wh...The Hong Kong-Kowloon Block,which has been uplifted continually and is stable since the late Cretaceous-Paleogene period,is identified and determined as a potential source with a maximum credible magnitude of M=5.5,while the late Cretaceous-Paleogene fault basins located around the Hong Kong-Kowloon Block are determinated as a potential source with a maximum credible magnitude of M≥6.0 based on the characteristics of seismo-tectonic activities in Hong Kong and its adjacent regions.The attenuation law of peak ground acceleration(PGA)and standard response spectra of acceleration(β)with damping 5% underlain by basement were determined by comparing the Chinese continent with the western U.S.A.in the similarity of tectonic environment of continental earthquakes,potential source with credible seismic magnitude of 5.0-7.5,and considering ground motion saturation near the source.The near source attenuation model of acceleration and response spectrum also reflect the field of Intensity distribution in East展开更多
b Département de Physique, Ecole Polythechnique Fédérale de Lausanne, EPFL, Lausanne, Switzerland c Department of Chemistry, Tsinghua University, Beijing 100084, China An excellent hole-transpor...b Département de Physique, Ecole Polythechnique Fédérale de Lausanne, EPFL, Lausanne, Switzerland c Department of Chemistry, Tsinghua University, Beijing 100084, China An excellent hole-transport material, 1,3-diphenyl-5-(9-phenanthryl)-2-pyrazoline (DPPhP) for OLEDs was studied. This compound not only offers high glass transition temperature (T g=96 ℃), good film forming ability, and high HOMO energy level, but also displays excellent hole-transport property. The electroluminescent device with a simple structure of ITO/DPPhP (60 nm)/AlQ (60 nm)/LiF (0.8 nm)/Al shows an external quantum efficiency as high as 1.6%.展开更多
文摘The precision of results obtained from the ^109Cd K XRF in vivo measurement system of bone lead for obses subjects with high BMI( body mass index)was poor.The main factor affecting the precision was the distance between tibia and detector.Compared with the standard phantom,a large phantom was used to simulate the obese subject in the measurements at different distances to the detector.The counts of Compton scattering increased highly because of the tissue overlying and surrounding tibia of the obese subject.When the distance between leg and detector was too small,the instrument would produce the distorted X-ray spectra,so that the obtained data were inaccurate,In order to ensure good measuremtn precision and accuracy,the distance between leg and detector should be maintained at 25mm during the counting period.Meanwhile,the dead time displayed instantly on the instrument should be controlled to around 30%.
文摘The Hong Kong-Kowloon Block,which has been uplifted continually and is stable since the late Cretaceous-Paleogene period,is identified and determined as a potential source with a maximum credible magnitude of M=5.5,while the late Cretaceous-Paleogene fault basins located around the Hong Kong-Kowloon Block are determinated as a potential source with a maximum credible magnitude of M≥6.0 based on the characteristics of seismo-tectonic activities in Hong Kong and its adjacent regions.The attenuation law of peak ground acceleration(PGA)and standard response spectra of acceleration(β)with damping 5% underlain by basement were determined by comparing the Chinese continent with the western U.S.A.in the similarity of tectonic environment of continental earthquakes,potential source with credible seismic magnitude of 5.0-7.5,and considering ground motion saturation near the source.The near source attenuation model of acceleration and response spectrum also reflect the field of Intensity distribution in East
文摘b Département de Physique, Ecole Polythechnique Fédérale de Lausanne, EPFL, Lausanne, Switzerland c Department of Chemistry, Tsinghua University, Beijing 100084, China An excellent hole-transport material, 1,3-diphenyl-5-(9-phenanthryl)-2-pyrazoline (DPPhP) for OLEDs was studied. This compound not only offers high glass transition temperature (T g=96 ℃), good film forming ability, and high HOMO energy level, but also displays excellent hole-transport property. The electroluminescent device with a simple structure of ITO/DPPhP (60 nm)/AlQ (60 nm)/LiF (0.8 nm)/Al shows an external quantum efficiency as high as 1.6%.