期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Highly Active Interfacial Sites in SFT-SnO_(2) Heterojunction Electrolyte for Enhanced Fuel Cell Performance via Engineered Energy Bands:Envisioned Theoretically and Experimentally 被引量:1
1
作者 Sajid Rauf Muhammad Bilal Hanif +8 位作者 faiz wali Zuhra Tayyab Bin Zhu Naveed Mushtaq Yatao Yang Kashif Khan Peter D.Lund Martin Motola Wei Xu 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2024年第3期384-397,共14页
Extending the ionic conductivity is the pre-requisite of electrolytes in fuel cell technology for high-electrochemical performance.In this regard,the introduction of semiconductor-oxide materials and the approach of h... Extending the ionic conductivity is the pre-requisite of electrolytes in fuel cell technology for high-electrochemical performance.In this regard,the introduction of semiconductor-oxide materials and the approach of heterostructure formation by modulating energy bands to enhance ionic conduction acting as an electrolyte in fuel cell-device.Semiconductor(n-type;SnO_(2))plays a key role by introducing into p-type SrFe_(0.2)Ti_(0.8)O_(3-δ)(SFT)semiconductor perovskite materials to construct p-n heterojunction for high ionic conductivity.Therefore,two different composites of SFT and SnO_(2)are constructed by gluing p-and n-type SFT-SnO_(2),where the optimal composition of SFT-SnO_(2)(6∶4)heterostructure electrolyte-based fuel cell achieved excellent ionic conductivity 0.24 S cm^(-1)with power-output of 1004 mW cm^(-2)and high OCV 1.12 V at a low operational temperature of 500℃.The high power-output and significant ionic conductivity with durable operation of 54 h are accredited to SFT-SnO_(2)heterojunction formation including interfacial conduction assisted by a built-in electric field in fuel cell device.Moreover,the fuel conversion efficiency and considerable Faradaic efficiency reveal the compatibility of SFT-SnO_(2)heterostructure electrolyte and ruled-out short-circuiting issue.Further,the first principle calculation provides sufficient information on structure optimization and energy-band structure modulation of SFT-SnO_(2).This strategy will provide new insight into semiconductor-based fuel cell technology to design novel electrolytes. 展开更多
关键词 high ionic conductivity interfacial conduction modulated energy band structure p-n heterojunction SEMICONDUCTORS
下载PDF
Non-destructive study of fruits using grating-based X-ray imaging
2
作者 Sheng-Xiang Wang Ren-Fang Hu +5 位作者 Kun Gao faiz wali Gui-Bin Zan Da-Jiang Wang Zhi-Yun Pan Shi-Qiang Wei 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第2期57-60,共4页
Grating-based X-ray imaging can make use of conventional tube sources to provide absorption, refraction and scattering contrast images from a single set of projection images efficiently. In this paper, a fresh cherry ... Grating-based X-ray imaging can make use of conventional tube sources to provide absorption, refraction and scattering contrast images from a single set of projection images efficiently. In this paper, a fresh cherry tomato and a dried umeboshi are imaged by using X-ray Talbot–Lau interferometer. The seed distribution in the scattering image of the cherry tomato, and the wrinkles of epicarp in the refraction image of the umeboshi, are shown distinctly. The refraction and scattering images provide more information on subtle features than the absorption image. Also, the contrast-to-noise ratio values show distinguishing capacity of the three kinds of imaging techniques. The results confirm that grating-based X-ray imaging is of great potential in non-destructive fruit testing. 展开更多
关键词 NON-DESTRUCTIVE TESTING X-ray imaging Talbot–Lau INTERFEROMETER FRUIT TESTING
下载PDF
Single-shot grating-based x-ray differential phase contrast imaging with a modified analyzer grating
3
作者 卫晨希 吴朝 +6 位作者 faiz wali 魏文彬 鲍园 骆荣辉 王磊 刘刚 田扬超 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第10期501-507,共7页
X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping informa... X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping information extraction method reduces system stability and prolongs data acquisition time by several times compared with conventional x-ray absorption- based imaging. The mechanical stepping can be avoided by using a staggered grating, but at the cost of low vertical spatial resolution. In this paper, employing a modified staggered grating and the angular signal radiography, we proposed a single-shot grating-based x-ray differential phase contrast imaging with decent vertical spatial resolution. The theoretical framework was deduced and proved by numerical experiments. Absorption, phase, and scattering computed tomography can be performed without phase stepping. Therefore, we believe this fast and highly stable imaging method with decent resolution would be widely applied in x-ray grating-based phase contrast imaging. 展开更多
关键词 x-ray phase contrast imaging single-shot decent resolution staggered grating computed tomography
下载PDF
Elemental x-ray imaging using Zernike phase contras
4
作者 邵其刚 陈健 +5 位作者 faiz wali 鲍园 王志立 朱佩平 田扬超 高昆 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第10期545-548,共4页
We develop an element-specific x-ray microscopy method by using Zernike phase contrast imaging near absorption edges, where a real part of refractive index changes abruptly. In this method two phase contrast images ar... We develop an element-specific x-ray microscopy method by using Zernike phase contrast imaging near absorption edges, where a real part of refractive index changes abruptly. In this method two phase contrast images are subtracted to obtain the target element: one is at the absorption edge of the target element and the other is near the absorption edge. The x-ray exposure required by this method is expected to be significantly lower than that of conventional absorption-based x-ray elemental imaging methods. Numerical calculations confirm the advantages of this highly efficient imaging method. 展开更多
关键词 x-ray imaging Zernike phase contrast elemental imaging
下载PDF
High efficiency positive and negative phase zone plates
5
作者 胡仁芳 陈健 +3 位作者 faiz wali 王声翔 高昆 刘刚 《Chinese Optics Letters》 SCIE EI CAS CSCD 2017年第2期11-14,共4页
We design a new kind of phase zone plates(PZPs) to improve the diffraction efficiency of soft x ray zone plates(ZPs). The design replaces blank parts of PZPs with metals of negative phase shift at the working ener... We design a new kind of phase zone plates(PZPs) to improve the diffraction efficiency of soft x ray zone plates(ZPs). The design replaces blank parts of PZPs with metals of negative phase shift at the working energy, which is called as the positive and negative PZPs(PNPZPs). According to the calculation, PNPZPs have a higher maximum efficiency than conventional ZPs with the same zone width. With the help of a negative phase coefficient, it is much easier to achieve a π phase shift in one period, resulting in a smaller zone height. This design can help fabricate finer PZPs to achieve a better image resolution. 展开更多
关键词 Image resolution Production platforms X ray diffraction
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部