Inconvenient dual-laser irradiation and tumor hypoxic environment as well as limited judgment of treating region have impeded the development of combined photothermal and photodynamic therapies(PTT and PDT).Herein,Bi2...Inconvenient dual-laser irradiation and tumor hypoxic environment as well as limited judgment of treating region have impeded the development of combined photothermal and photodynamic therapies(PTT and PDT).Herein,Bi2Se3@AIPH nanoparticles(NPs)are facilely developed to overcome these problems.Through a one-step method,free radical generator(AIPH)and phase transition material(lauric acid,LA,44-46°C)are encapsulated in hollow bismuth selenide nanoparticles(Bi2Se3 NPs).Under a single 808-nm laser irradiation at the tumor area,hyperthermia produced by Bi2Se3 not only directly leads to cell death,but also promotes AIPH release by melting LA and triggers free radical generation,which could further eradicate tumor cells in hypoxic environments.Moreover,Bi2Se3 with high X-ray attenuation coefficient endows the NPs with high computed tomography(CT)imaging capability,which is important for treating area determination.The results exhibit that Bi2Se3@AIPH NPs possesses 31.2%photothermal conversion efficiency for enhanced PTT,ideal free radical generation for oxygen-independent PDT,and 37.77 HU mL mg?1 X-ray attenuation coefficient for CT imaging with high quality.Most importantly,the tumor growth inhibition rate by synergistic PTT,PDT,and following immunotherapy is 99.6%,and even one tumor disappears completely,which demonstrates excellent cascaded synergistic effect of Bi2Se3@AIPH NPs for the tumor therapy.展开更多
BACKGROUND Occult hepatitis B infection(OBI)is characterized by the detection of hepatitis B virus(HBV)DNA in serum(usually HBV DNA<200 IU/mL)or the liver but negativity for hepatitis B surface antigen(HBsAg).The d...BACKGROUND Occult hepatitis B infection(OBI)is characterized by the detection of hepatitis B virus(HBV)DNA in serum(usually HBV DNA<200 IU/mL)or the liver but negativity for hepatitis B surface antigen(HBsAg).The diagnosis of OBI relies on the sensitivity of assays used in the detection of HBV DNA and HBsAg.HBsAg assays with inadequate sensitivity or inability to detect HBV S variants may lead to misdiagnosis of OBI in people with overt HBV infection.CASE SUMMARY We report a HBsAg-negative but hepatitis B envelope antigen-positive patient who had a significant HBV DNA level.The patient was initially diagnosed as having OBI.However,sequence analysis revealed a unique insertion of amino acid residues at positions 120-124 in the S protein,which affects the formation of a disulfide bond that is associated with the formation of a loop.It is well known that there is an overlap between the S protein and Pol protein.We found that this new insertion site occurred in polymerase/reverse transcriptase domain,indi-cating that this insertion might be involved in HBV pathogenicity.The patient was finally diagnosed with a false OBI.CONCLUSION An insertion of amino acid residues at positions 120-124 of the S protein affects the formation of immunodominant epitopes and results in negative HBsAg levels.展开更多
The detection of bacterial pathogen such as Staphylococcus aureus(S.aureus) is essential for the regulation of food hygiene and disease diagnosis.Herein,we developed a simple one-step fluorescence resonance energy tra...The detection of bacterial pathogen such as Staphylococcus aureus(S.aureus) is essential for the regulation of food hygiene and disease diagnosis.Herein,we developed a simple one-step fluorescence resonance energy transfer(FRET)-based sensor for specific and sensitive detection of S.aureus in food and serum samples,in which aptamer-modified quantum dots(aptamer-QDs) was employed as the energy donor and antibiotic of teicoplanin functionalized-gold nanoparticles(Teico-AuNPs) was chosen as the energy acceptor.Within 1 h,the FRET-based sensor showed a linear range of from 10 cfu/mL to 5 × 10^(8) cfu/mL,with the low limit of detection(LOD,2 cfu/mL) for S.aureus in buffer.When further applied to assay S.aureus in real samples,the FRET-based sensor showed good recoveries ranging from 84.5% to 110.0%,with relative standard derivations(RSDs) of 0.01%-0.44% and a LOD of 100 cfu/mL in milk,orange juice and human serum.展开更多
基金supported by the National Natural Science Foundation of China(Nos.51433004 and 51773096)Natural Science Foundation of Tianjin(No.17JCZDJC33500)PCSIRT(IRT1257).
文摘Inconvenient dual-laser irradiation and tumor hypoxic environment as well as limited judgment of treating region have impeded the development of combined photothermal and photodynamic therapies(PTT and PDT).Herein,Bi2Se3@AIPH nanoparticles(NPs)are facilely developed to overcome these problems.Through a one-step method,free radical generator(AIPH)and phase transition material(lauric acid,LA,44-46°C)are encapsulated in hollow bismuth selenide nanoparticles(Bi2Se3 NPs).Under a single 808-nm laser irradiation at the tumor area,hyperthermia produced by Bi2Se3 not only directly leads to cell death,but also promotes AIPH release by melting LA and triggers free radical generation,which could further eradicate tumor cells in hypoxic environments.Moreover,Bi2Se3 with high X-ray attenuation coefficient endows the NPs with high computed tomography(CT)imaging capability,which is important for treating area determination.The results exhibit that Bi2Se3@AIPH NPs possesses 31.2%photothermal conversion efficiency for enhanced PTT,ideal free radical generation for oxygen-independent PDT,and 37.77 HU mL mg?1 X-ray attenuation coefficient for CT imaging with high quality.Most importantly,the tumor growth inhibition rate by synergistic PTT,PDT,and following immunotherapy is 99.6%,and even one tumor disappears completely,which demonstrates excellent cascaded synergistic effect of Bi2Se3@AIPH NPs for the tumor therapy.
基金Supported by the Shanghai Municipal Commission of Health and Family Planning,No.PKJ2018-Y05.
文摘BACKGROUND Occult hepatitis B infection(OBI)is characterized by the detection of hepatitis B virus(HBV)DNA in serum(usually HBV DNA<200 IU/mL)or the liver but negativity for hepatitis B surface antigen(HBsAg).The diagnosis of OBI relies on the sensitivity of assays used in the detection of HBV DNA and HBsAg.HBsAg assays with inadequate sensitivity or inability to detect HBV S variants may lead to misdiagnosis of OBI in people with overt HBV infection.CASE SUMMARY We report a HBsAg-negative but hepatitis B envelope antigen-positive patient who had a significant HBV DNA level.The patient was initially diagnosed as having OBI.However,sequence analysis revealed a unique insertion of amino acid residues at positions 120-124 in the S protein,which affects the formation of a disulfide bond that is associated with the formation of a loop.It is well known that there is an overlap between the S protein and Pol protein.We found that this new insertion site occurred in polymerase/reverse transcriptase domain,indi-cating that this insertion might be involved in HBV pathogenicity.The patient was finally diagnosed with a false OBI.CONCLUSION An insertion of amino acid residues at positions 120-124 of the S protein affects the formation of immunodominant epitopes and results in negative HBsAg levels.
基金supported by the National Natural Science Foundation of China (Nos.21974110,21575118,21976145 and 31672605)Natural Science Foundation Project of Chongqing (No.CSTC2019jcyj-msxmX0406)。
文摘The detection of bacterial pathogen such as Staphylococcus aureus(S.aureus) is essential for the regulation of food hygiene and disease diagnosis.Herein,we developed a simple one-step fluorescence resonance energy transfer(FRET)-based sensor for specific and sensitive detection of S.aureus in food and serum samples,in which aptamer-modified quantum dots(aptamer-QDs) was employed as the energy donor and antibiotic of teicoplanin functionalized-gold nanoparticles(Teico-AuNPs) was chosen as the energy acceptor.Within 1 h,the FRET-based sensor showed a linear range of from 10 cfu/mL to 5 × 10^(8) cfu/mL,with the low limit of detection(LOD,2 cfu/mL) for S.aureus in buffer.When further applied to assay S.aureus in real samples,the FRET-based sensor showed good recoveries ranging from 84.5% to 110.0%,with relative standard derivations(RSDs) of 0.01%-0.44% and a LOD of 100 cfu/mL in milk,orange juice and human serum.