Full-field transmission X-ray microscopy(TXM)is a powerful non-destructive three-dimensional(3D)imaging method with a nanoscale spatial resolution that has been used in most synchrotron facilities worldwide.An in-hous...Full-field transmission X-ray microscopy(TXM)is a powerful non-destructive three-dimensional(3D)imaging method with a nanoscale spatial resolution that has been used in most synchrotron facilities worldwide.An in-house-designed TXM system was constructed at the BL18B 3D nanoimaging beamline at the Shanghai Synchrotron Radiation Facility.The beamline operates from 5 to 14 keV and enables 20 nm spatial resolution imaging.The characterization details of the beamline are described in this paper.The performances in terms of spatial resolution,nano-CT,and nano-spectral imaging of the TXM beamline are also presented in this article.展开更多
A new X-ray imaging and biomedical application beamline(BL13HB)has been implemented at the Shanghai Radiation Synchrotron Facility(SSRF)as an upgrade to the old X-ray imaging and biomedical application beamline(BL13W1...A new X-ray imaging and biomedical application beamline(BL13HB)has been implemented at the Shanghai Radiation Synchrotron Facility(SSRF)as an upgrade to the old X-ray imaging and biomedical application beamline(BL13W1).This is part of the Phase II construction project of the SSRF.The BL13HB is dedicated to 2D and 3D static and dynamic X-ray imaging,with a field of view of up to 48.5 mm×5.2 mm and spatial resolution as high as 0.8μm.A super-bending magnet is used as the X-ray source in BL13HB,which has a maximum magnetic field of 2.293 T.The energy range of monochromatic X-ray photons from a double-multiplayer monochromator was 8–40 keV,and the white beam mode was provided on the beamline for dynamic X-ray imaging and dynamic X-ray micro-CT.While maintaining the previous experimental setup of BL13W1,new equipment was added to the beamline experimental station.The beamline is equipped with different sets of X-ray imaging detectors for several experimental methods such as micro-CT,dynamic micro-CT,and pair distribution function.The experimental station of BL13HB is designed specifically for various in situ dynamic experiments,and BL13HB has been open to users since June 2021.展开更多
基金supported by the National Key Research and Development Program of China(Nos.2021YFA1600703,2021YFF0701202,and 2021YFA1601001)the National Natural Science Foundation of China(Nos.12275343 and U1932205)。
文摘Full-field transmission X-ray microscopy(TXM)is a powerful non-destructive three-dimensional(3D)imaging method with a nanoscale spatial resolution that has been used in most synchrotron facilities worldwide.An in-house-designed TXM system was constructed at the BL18B 3D nanoimaging beamline at the Shanghai Synchrotron Radiation Facility.The beamline operates from 5 to 14 keV and enables 20 nm spatial resolution imaging.The characterization details of the beamline are described in this paper.The performances in terms of spatial resolution,nano-CT,and nano-spectral imaging of the TXM beamline are also presented in this article.
基金supported by the National Major Scientific Instruments and Equipment Development Project of China(No.11627901)the National Key Research and Development Program of China(Nos.2021YFF0701202 and 2021YFA1600703)the National Natural Science Foundation of China(Nos.U1932205,12275343)。
文摘A new X-ray imaging and biomedical application beamline(BL13HB)has been implemented at the Shanghai Radiation Synchrotron Facility(SSRF)as an upgrade to the old X-ray imaging and biomedical application beamline(BL13W1).This is part of the Phase II construction project of the SSRF.The BL13HB is dedicated to 2D and 3D static and dynamic X-ray imaging,with a field of view of up to 48.5 mm×5.2 mm and spatial resolution as high as 0.8μm.A super-bending magnet is used as the X-ray source in BL13HB,which has a maximum magnetic field of 2.293 T.The energy range of monochromatic X-ray photons from a double-multiplayer monochromator was 8–40 keV,and the white beam mode was provided on the beamline for dynamic X-ray imaging and dynamic X-ray micro-CT.While maintaining the previous experimental setup of BL13W1,new equipment was added to the beamline experimental station.The beamline is equipped with different sets of X-ray imaging detectors for several experimental methods such as micro-CT,dynamic micro-CT,and pair distribution function.The experimental station of BL13HB is designed specifically for various in situ dynamic experiments,and BL13HB has been open to users since June 2021.