Combined cooling and power(CCP)system driven by low-grade heat is promising for improving energy efficiency.This work proposes a CCP system that integrates a regenerative organic Rankine cycle(RORC)and an absorption c...Combined cooling and power(CCP)system driven by low-grade heat is promising for improving energy efficiency.This work proposes a CCP system that integrates a regenerative organic Rankine cycle(RORC)and an absorption chiller on both driving and cooling fluid sides.The system is modeled by using the heat current method to fully consider nonlinear heat transfer and heat-work conversion constraints and resolve its behavior accurately.The off-design system simulation is performed next,showing that the fluid inlet temperatures and flow rates of cooling water as well as RORC working fluid strongly affect system performance.The off-design operation even becomes infeasible when parameters deviate from nominal values largely due to limited heat transfer capability of components,highlighting the importance of considering heat transfer constraints via heat current method.Design optimization aiming to minimize the total thermal conductance is also conducted.RORC efficiency increases by 7.9%and decreases by 12.4%after optimization,with the hot fluid inlet temperature increase from 373.15 to 403.15 K and mass flow rate ranges from 10 to 30 kg/s,emphasizing the necessity of balancing system cost and performance.展开更多
Liquid cooling systems in data centers have been attracting more attentions due to its better cooling capability and less energy consumption. In order to propose an effective optimization method for the operation of i...Liquid cooling systems in data centers have been attracting more attentions due to its better cooling capability and less energy consumption. In order to propose an effective optimization method for the operation of indirect liquid cooling systems, this paper first constructs an experiment platform and applies the heat current method to build the global heat transfer constraints of the whole system. Particularly, the thermal conductance of each heat exchanger under different working conditions is predicted by the Artificial Neural Networks(ANN) trained by the historical data. On this basis, combining the heat transfer and fluid flow constraints together with the Lagrange multiplier method builds the optimization model with the objective of minimum pumping power consumption(PPC), solving which by the solution strategy designed obtains the optimal frequencies of the variable frequency pumps(VFPs). Operating with the optimal and other feasible operating conditions validates the optimization model. Meanwhile, the experiments with variable heat loads and flow resistances provide some guidelines for the optimal system operation. For instance, to address heat load increase of a branch, it needs to increase the frequencies of the VFPs, not only the corresponding hot loop but also the whole cold loop.展开更多
基金supported by National Natural Science Foundation of China(Grant No.52125604)。
文摘Combined cooling and power(CCP)system driven by low-grade heat is promising for improving energy efficiency.This work proposes a CCP system that integrates a regenerative organic Rankine cycle(RORC)and an absorption chiller on both driving and cooling fluid sides.The system is modeled by using the heat current method to fully consider nonlinear heat transfer and heat-work conversion constraints and resolve its behavior accurately.The off-design system simulation is performed next,showing that the fluid inlet temperatures and flow rates of cooling water as well as RORC working fluid strongly affect system performance.The off-design operation even becomes infeasible when parameters deviate from nominal values largely due to limited heat transfer capability of components,highlighting the importance of considering heat transfer constraints via heat current method.Design optimization aiming to minimize the total thermal conductance is also conducted.RORC efficiency increases by 7.9%and decreases by 12.4%after optimization,with the hot fluid inlet temperature increase from 373.15 to 403.15 K and mass flow rate ranges from 10 to 30 kg/s,emphasizing the necessity of balancing system cost and performance.
基金supported by the National Natural Science Foundation of China(Grant Nos.51836004 and 51621062)the Fundamental Research Funds of Shandong University(No.32240072064035)。
文摘Liquid cooling systems in data centers have been attracting more attentions due to its better cooling capability and less energy consumption. In order to propose an effective optimization method for the operation of indirect liquid cooling systems, this paper first constructs an experiment platform and applies the heat current method to build the global heat transfer constraints of the whole system. Particularly, the thermal conductance of each heat exchanger under different working conditions is predicted by the Artificial Neural Networks(ANN) trained by the historical data. On this basis, combining the heat transfer and fluid flow constraints together with the Lagrange multiplier method builds the optimization model with the objective of minimum pumping power consumption(PPC), solving which by the solution strategy designed obtains the optimal frequencies of the variable frequency pumps(VFPs). Operating with the optimal and other feasible operating conditions validates the optimization model. Meanwhile, the experiments with variable heat loads and flow resistances provide some guidelines for the optimal system operation. For instance, to address heat load increase of a branch, it needs to increase the frequencies of the VFPs, not only the corresponding hot loop but also the whole cold loop.