It is critical for cerebral vascular disease diagnosis through Doppler to detect the maximum and the minimum of the carotid blood flow speed accurately. A kind of Duffing system under an external periodic power with d...It is critical for cerebral vascular disease diagnosis through Doppler to detect the maximum and the minimum of the carotid blood flow speed accurately. A kind of Duffing system under an external periodic power with dump is introduced in the letter, numerical analysis is carried out by four-order Runge-Kutta method. An oscillator array is designed according to the frequency of the ultrasonic wave. When the external signals are inputted, computational algorithm is used to scan the array in turn and analyze the result, and the frequency can be determined. Based on the methods above, detecting the carotid blood flow speed accurately is realized. The Signal-to-Noise Ratio (SNR) of-20.23dB is obtained by the result of experiments. In conclusion, the SNR has been improved and the precision of the measured bloodstream speed has been increased, which can be 0.069% to 0.13%.展开更多
As for the Domino effect dv/dt and electromagnetic interference during the rapid switching course of single-chip switching power supply,this article firstly analyzes electromagnetic interference source,and then diagno...As for the Domino effect dv/dt and electromagnetic interference during the rapid switching course of single-chip switching power supply,this article firstly analyzes electromagnetic interference source,and then diagnoses the essential interaction relationship between interference and switching activity based on the timely and area measured waveform,analyzes and studies the production mechanism and coupling path of interference mode,and sets up circuit model according to the features of transverse mode interference and common mode interference.Put forward different suppression methods finally.展开更多
基金Supported by the National Natural Science Foundation of China (No.60102002)the Huoyingdong Education Foundation (No.81057)the Doctoral Foundation of Hebei Province of China(No.B2004522).
文摘It is critical for cerebral vascular disease diagnosis through Doppler to detect the maximum and the minimum of the carotid blood flow speed accurately. A kind of Duffing system under an external periodic power with dump is introduced in the letter, numerical analysis is carried out by four-order Runge-Kutta method. An oscillator array is designed according to the frequency of the ultrasonic wave. When the external signals are inputted, computational algorithm is used to scan the array in turn and analyze the result, and the frequency can be determined. Based on the methods above, detecting the carotid blood flow speed accurately is realized. The Signal-to-Noise Ratio (SNR) of-20.23dB is obtained by the result of experiments. In conclusion, the SNR has been improved and the precision of the measured bloodstream speed has been increased, which can be 0.069% to 0.13%.
基金Tianjin Natunal science Foundation of China(No:05YFSYSF033)
文摘As for the Domino effect dv/dt and electromagnetic interference during the rapid switching course of single-chip switching power supply,this article firstly analyzes electromagnetic interference source,and then diagnoses the essential interaction relationship between interference and switching activity based on the timely and area measured waveform,analyzes and studies the production mechanism and coupling path of interference mode,and sets up circuit model according to the features of transverse mode interference and common mode interference.Put forward different suppression methods finally.