BACKGROUND The incidence and mortality of lung cancer have increased annually.Accurate diagnosis can help improve therapeutic efficacy of interventions and prognosis.Percutaneous lung biopsy is a reliable method for t...BACKGROUND The incidence and mortality of lung cancer have increased annually.Accurate diagnosis can help improve therapeutic efficacy of interventions and prognosis.Percutaneous lung biopsy is a reliable method for the clinical diagnosis of lung cancer.Ultrasound-guided percutaneous lung biopsy technology has been widely promoted and applied in recent years.AIM To investigate the diagnostic value of contrast-enhanced ultrasound(CEUS)-guided percutaneous biopsy in peripheral pulmonary lesions.METHODS We retrospectively collected data on 237 patients with peripheral thoracic focal lesions who underwent puncture biopsy at Wuxi People’s Hospital.The patients were randomly divided into two groups:The CEUS-guided before lesion puncture group(contrast group)and conventional ultrasound-guided group(control group).Analyze the diagnostic efficacy of the puncture biopsy,impact of tumor size,and number of puncture needles and complications were analyzed and compared between the two groups.RESULTS Accurate pathological results were obtained for 92.83%(220/237)of peripheral lung lesions during the first biopsy,with an accuracy rate of 95.8%(113/118)in the contrast group and 89.9%(107/119)in the control group.The difference in the area under the curve(AUC)between the contrast and the control groups was not statistically significant(0.952 vs 0.902,respectively;P>0.05).However,when the lesion diameter≥5 cm,the diagnostic AUC of the contrast group was higher than that of the control group(0.952 vs 0.902,respectively;P<0.05).In addition,the average number of puncture needles in the contrast group was lower than that in the control group(2.58±0.53 vs 2.90±0.56,respectively;P<0.05).CONCLUSION CEUS guidance can enhance the efficiency of puncture biopsy of peripheral pulmonary lesions,especially for lesions with a diameter≥5 cm.Therefore,CEUS guidance has high clinical diagnostic value in puncture biopsy of peripheral focal lung lesions.展开更多
AIM To describe contrast-enhanced ultrasound(CEUS) features and evaluate differential diagnosis value of CEUS and conventional ultrasound for patients with benign and malignant gallbladder lesions. METHODS This study ...AIM To describe contrast-enhanced ultrasound(CEUS) features and evaluate differential diagnosis value of CEUS and conventional ultrasound for patients with benign and malignant gallbladder lesions. METHODS This study included 105 gallbladder lesions. Before surgical resection and pathological examination, conventional ultrasound and CEUS were performed to examine for lesions. Then, all the lesions were diagnosed as(1) benign,(2) probably benign,(3) probably malignant or(4) malignant using both conventional ultrasound and CEUS. The CEUS features of these gallbladder lesions were analyzed and diagnostic efficiency between conventional ultrasound and CEUS was compared.RESULTS There were total 17 cases of gallbladder cancer and 88 cases of benign lesion. Some gallbladder lesions had typical characteristics on CEUS(e.g., gallbladder adenomyomatosis had typical characteristics of small nonenhanced areas on CEUS). The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of CEUS were 94.1%, 95.5%, 80.0%, 98.8%and 95.2%, respectively. These were significantly higher than conventional ultrasound(82.4%, 89.8%, 60.9%, 96.3% and 88.6%, respectively). CEUS had an accuracy of 100% for gallbladder sludge and CEUS helped in differential diagnosis among gallbladder polyps, gallbladder adenoma and gallbladder cancer.CONCLUSION CEUS may provide more useful information and improve the diagnosis efficiency for the diagnosis of gallbladder lesions than conventional ultrasound.展开更多
BACKGROUND It is important to differentiate benign and malignant focal liver lesions(FLLs)accurately.Despite the wide use and acceptance of shear wave elastography(SWE),its value for assessing the elasticity of FLLs a...BACKGROUND It is important to differentiate benign and malignant focal liver lesions(FLLs)accurately.Despite the wide use and acceptance of shear wave elastography(SWE),its value for assessing the elasticity of FLLs and differentiating benign and malignant FLLs is still investigational.Previous studies of SWE for FLLs used mean elasticity as the parameter to reflect the stiffness of FLLs.Considering the inhomogeneity of tumor stiffness,maximal elasticity(Emax)might be the suitable parameter to reflect the stiffness of FLLs and to differentiate malignant FLLs from benign ones.AIM To explore the value of SWE with Emax in differential diagnosis of solid FLLs.METHODS We included 104 solid FLLs in 95 patients and 50 healthy volunteers.All the subjects were examined using conventional ultrasound(US)and virtual touch tissue quantification(VTQ)imaging.A diagnosis of benign or malignant FLL was made using conventional US.Ten VTQ values were acquired after 10 consecutive measurements for each FLL and each normal liver,and the largest value was recorded as Emax.RESULTS There were 56 cases of malignant FLLs and 48 cases of benign FLLs in this study.Emax of malignant FLLs(3.29±0.88 m/s)was significantly higher than that of benign FLLs(1.30±0.46 m/s,P<0.01)and that of livers in healthy volunteers(1.15±0.17 m/s,P<0.01).The cut-off point of Emax was 1.945,and the area under the curve was 0.978.The sensitivity and specificity of Emax were 92.9%and 91.7%,respectively,higher(but not significantly)than those of conventional US(80.4%for sensitivity and 81.3%for specificity).Combined diagnosis of conventional US and Emax using parallel testing improved the sensitivity to 100%with specificity of 75%.CONCLUSION SWE is a convenient and easy method to obtain accurate stiffness information of solid FLLs.Emax is useful for differential diagnosis of FLLs,especially in combination with conventional US.展开更多
基金the Ethic Committee of Wuxi People's Hospital(No.KY17071).
文摘BACKGROUND The incidence and mortality of lung cancer have increased annually.Accurate diagnosis can help improve therapeutic efficacy of interventions and prognosis.Percutaneous lung biopsy is a reliable method for the clinical diagnosis of lung cancer.Ultrasound-guided percutaneous lung biopsy technology has been widely promoted and applied in recent years.AIM To investigate the diagnostic value of contrast-enhanced ultrasound(CEUS)-guided percutaneous biopsy in peripheral pulmonary lesions.METHODS We retrospectively collected data on 237 patients with peripheral thoracic focal lesions who underwent puncture biopsy at Wuxi People’s Hospital.The patients were randomly divided into two groups:The CEUS-guided before lesion puncture group(contrast group)and conventional ultrasound-guided group(control group).Analyze the diagnostic efficacy of the puncture biopsy,impact of tumor size,and number of puncture needles and complications were analyzed and compared between the two groups.RESULTS Accurate pathological results were obtained for 92.83%(220/237)of peripheral lung lesions during the first biopsy,with an accuracy rate of 95.8%(113/118)in the contrast group and 89.9%(107/119)in the control group.The difference in the area under the curve(AUC)between the contrast and the control groups was not statistically significant(0.952 vs 0.902,respectively;P>0.05).However,when the lesion diameter≥5 cm,the diagnostic AUC of the contrast group was higher than that of the control group(0.952 vs 0.902,respectively;P<0.05).In addition,the average number of puncture needles in the contrast group was lower than that in the control group(2.58±0.53 vs 2.90±0.56,respectively;P<0.05).CONCLUSION CEUS guidance can enhance the efficiency of puncture biopsy of peripheral pulmonary lesions,especially for lesions with a diameter≥5 cm.Therefore,CEUS guidance has high clinical diagnostic value in puncture biopsy of peripheral focal lung lesions.
基金Supported by the National Natural Science Foundation of China,No.81301232
文摘AIM To describe contrast-enhanced ultrasound(CEUS) features and evaluate differential diagnosis value of CEUS and conventional ultrasound for patients with benign and malignant gallbladder lesions. METHODS This study included 105 gallbladder lesions. Before surgical resection and pathological examination, conventional ultrasound and CEUS were performed to examine for lesions. Then, all the lesions were diagnosed as(1) benign,(2) probably benign,(3) probably malignant or(4) malignant using both conventional ultrasound and CEUS. The CEUS features of these gallbladder lesions were analyzed and diagnostic efficiency between conventional ultrasound and CEUS was compared.RESULTS There were total 17 cases of gallbladder cancer and 88 cases of benign lesion. Some gallbladder lesions had typical characteristics on CEUS(e.g., gallbladder adenomyomatosis had typical characteristics of small nonenhanced areas on CEUS). The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of CEUS were 94.1%, 95.5%, 80.0%, 98.8%and 95.2%, respectively. These were significantly higher than conventional ultrasound(82.4%, 89.8%, 60.9%, 96.3% and 88.6%, respectively). CEUS had an accuracy of 100% for gallbladder sludge and CEUS helped in differential diagnosis among gallbladder polyps, gallbladder adenoma and gallbladder cancer.CONCLUSION CEUS may provide more useful information and improve the diagnosis efficiency for the diagnosis of gallbladder lesions than conventional ultrasound.
基金Natural Science Foundation of Shanghai of China,No.19ZR1441500.
文摘BACKGROUND It is important to differentiate benign and malignant focal liver lesions(FLLs)accurately.Despite the wide use and acceptance of shear wave elastography(SWE),its value for assessing the elasticity of FLLs and differentiating benign and malignant FLLs is still investigational.Previous studies of SWE for FLLs used mean elasticity as the parameter to reflect the stiffness of FLLs.Considering the inhomogeneity of tumor stiffness,maximal elasticity(Emax)might be the suitable parameter to reflect the stiffness of FLLs and to differentiate malignant FLLs from benign ones.AIM To explore the value of SWE with Emax in differential diagnosis of solid FLLs.METHODS We included 104 solid FLLs in 95 patients and 50 healthy volunteers.All the subjects were examined using conventional ultrasound(US)and virtual touch tissue quantification(VTQ)imaging.A diagnosis of benign or malignant FLL was made using conventional US.Ten VTQ values were acquired after 10 consecutive measurements for each FLL and each normal liver,and the largest value was recorded as Emax.RESULTS There were 56 cases of malignant FLLs and 48 cases of benign FLLs in this study.Emax of malignant FLLs(3.29±0.88 m/s)was significantly higher than that of benign FLLs(1.30±0.46 m/s,P<0.01)and that of livers in healthy volunteers(1.15±0.17 m/s,P<0.01).The cut-off point of Emax was 1.945,and the area under the curve was 0.978.The sensitivity and specificity of Emax were 92.9%and 91.7%,respectively,higher(but not significantly)than those of conventional US(80.4%for sensitivity and 81.3%for specificity).Combined diagnosis of conventional US and Emax using parallel testing improved the sensitivity to 100%with specificity of 75%.CONCLUSION SWE is a convenient and easy method to obtain accurate stiffness information of solid FLLs.Emax is useful for differential diagnosis of FLLs,especially in combination with conventional US.