The filling and exhausting processes in a pneumatic system are involved with many factors, and numerical solutions of many partial differential equations are always adapted in the study of those processes, which have ...The filling and exhausting processes in a pneumatic system are involved with many factors, and numerical solutions of many partial differential equations are always adapted in the study of those processes, which have been proved to be troublesome and less intuitive. Analytical solutions based on loss-less tube model and average friction tube model are found respectively by using fluid net theory, and they fit the experimental results well. The research work shows that: Fluid net theory can be used to solve the analytical solution of filling and exhausting processes of pneumatic system, and the result of loss-less tube model is close to that of average friction model, so loss-less tube model is recommended since it is simpler, and the difference between filling time and exhausting time is determined by initial and final pressures, the volume of container and the section area of tube, and has nothing to do with the length of the tube.展开更多
The condensation in pneumatic system is a complex physical phenomenon dependant upon status variation and phase transitions,which are related to the parameters of the compressed air,atmospheric conditions and the dime...The condensation in pneumatic system is a complex physical phenomenon dependant upon status variation and phase transitions,which are related to the parameters of the compressed air,atmospheric conditions and the dimensions of the pneumatic components.Up to now,general research method for this problem is to calculate the status variation and movement quantity by numerical simulation and experiment directly.The comprehensive parameters composed of several different effect factors are rarely used to study the condensation.The composed components and the working conditions of each cylinder are different,a large number of experiments and complex calculations are necessary to determine the condensation.Additionally,the transferability of the determined results is poor.In this paper,the charging and discharging systems of serials cylinder with different structure parameters are studied.The condensation of the systems is observed and the effects of the structure parameters on condensation are analyzed.The changing trends of relative humidity,natural frequency and average speed against the structural parameters of the components during discharge of the pneumatic systems are analyzed.Three comprehensive parameters used to analyze and determine condensation composed by structure parameters of components are proposed,namely,the ratio of the effective area of the discharge tube and the container volume,the square root of the effective area of the discharge tube divided by the product of the container volume and the length of the discharge tube,and the discharge dimensionless tube-volume.The experimental results show that these comprehensive parameters can be used to quantitatively determine whether internal,external or zero condensation occurs in a pneumatic system,and can be also used to quantitatively analyze the experimental data of condensation in pneumatic systems directly.At the same time,the effect factors are too much and the effect relationships are very complex,which causes that the conclusions can't be put forward by using single effect factor in experimental data processing individually.The three obtained comprehensive parameters can be used to resolve the above problem.The proposed parameters can also resolve the problem of poor transferability in determining the state of condensation in pneumatic systems,and provide a novel method for the further study of condensation theory.展开更多
To investigate the unsteady flow characteristics in centrifugal pump, the flow field in a low-specific-speed centri- fugal pump with complex impeller is numerically simulated under different conditions. The RNG r-e tu...To investigate the unsteady flow characteristics in centrifugal pump, the flow field in a low-specific-speed centri- fugal pump with complex impeller is numerically simulated under different conditions. The RNG r-e turbulence model and sliding mesh are adopted during the process of computation. The results show that the interaction be- tween impeller and volute results in the unstable flow of the fluid, which causes the uneven distribution of pres- sure fluctuations around the circumference of volute. Besides the main frequency and its multiple frequency of pressure fluctuations in the centrifugal pump, the frequency caused by the long blades of complex impeller also plays a dominant role in the low-frequency areas. Furthermore, there exists biggish fluctuation phenomenon near the tongue. The composition of static pressure fluctuations frequency on the volute wall and blade outlet is similar except that the fluctuation amplitude near the volute wall reduces. In general, the different flow rates mainly have influence on the amplitude of fluctuation frequency in the pump, while have little effect on the frequency compo- sition.展开更多
Aerodynamic performance of an axial flow fan is closely related to its tip clearance leakage flow. In this paper, the hot-wire anemometer is used to measure the three dimensional mean velocity near the blade tips. Mor...Aerodynamic performance of an axial flow fan is closely related to its tip clearance leakage flow. In this paper, the hot-wire anemometer is used to measure the three dimensional mean velocity near the blade tips. Moreover, the filtered N-S equations with finite volume method and RNG k-s turbulence model are adopted to carry out the steady simulation calculation of several fans that differ only in tip flange shape and number. The large eddy simulation and the FW-H noise models are adopted to carry out the unsteady numerical calculation and aerodynamic noise prediction. The results of simulation calculation agree roughly with that of tests, which proves the numerical calculation method is feasible.The effects of tip flange shapes and numbers on the blade tip vortex structure and the characteristics are analyzed. The results show that tip flange of the fan has a certain influence on the characteristics of the fan. The maximum efficiencies for the fans with tip flanges are shifted towards partial flow with respect to the design point of the dattun fan. Furthermore, the noise characteristics for the fans with tip flanges have become more deteriorated than that for the datum fan. Tip flange contributes to forming tip vortex shedding and the effect of the half-cylinder tip flange on tip vortex shedding is obvious. There is a distinct rela- tionship between the characteristics of the fan and tip vortex shedding.The research results provide the profitable reference for the internal flow mechanism of the performance optimization of small axial flow fans.展开更多
To improve the aerodynamic performance of small axial flow fan, in this paper the design of a small axial flow fan with splitter blades is studied. The RNG k-e turbulence model and SIMPLE algorithm were applied to the...To improve the aerodynamic performance of small axial flow fan, in this paper the design of a small axial flow fan with splitter blades is studied. The RNG k-e turbulence model and SIMPLE algorithm were applied to the steady simulation calculation of the flow field, and its result was used as the initial field of the large eddy simulation to calculate the unsteady pressure field. The FW-H noise model was adopted to predict aerodynamic noise in the six monitoring points. Fast Fourier transform algorithm was applied to process the pressure signal. Experiment of noise testing was done to further investigate the aerodynamic noise of fans. And then the results obtained from the numerical simulation and experiment were described and analyzed. The results show that the static characteristics of small axial fan with splitter blades are similar with the prototype fan, and the static characteristics are improved within a certain range of flux. The power spectral density at the six monitoring points of small axial flow fan with splitter blades have decreased to some extent. The experimental results show sound pressure level of new fan has reduced in most frequency bands by comparing with prototype fan. The research results will provide a proof for parameter optimization and noise prediction of small axial flow fans with high performance.展开更多
Effects of the inlet guide vanes on the static characteristics, aerodynamic noise and internal flow characteristics of a small axial flow fan are studied in this work. The inlet guide vanes with different outlet angle...Effects of the inlet guide vanes on the static characteristics, aerodynamic noise and internal flow characteristics of a small axial flow fan are studied in this work. The inlet guide vanes with different outlet angle are designed, which are mounted on the casing and located at the upstream of the impeller of the prototype fan. Both steady and unsteady flow simulations arc performed. The steady flow is simulated by the calculations of Navier-Stokes equa- tions coupled with RNG k-epsilon turbulence model, while the unsteady flow is computed with large eddy simu- lation. According to the theoretical analysis, the inlet guide vanes with outlet angle of 60° are regarded as the op- timal inlet guide vanes. The static characteristic experiment is carried out in a standard test rig and the aerody- namic noise is tested in a semi-anechoic room. Then, performances of the fan with optimal inlet guide vanes are compared with those of the prototype fan. The results show that there is reasonable agreement between the simu- lation results and the experimental data. It is found that the static characteristics of small axial flow fan is im- proved obviously after installing the optimal inlet guide vanes. Meanwhile, the optimal inlet guide vanes have effect on reducing noise at the near field, but have little effect on the noise at the far field.展开更多
In order to analyze the influence of blade outlet angle on inner flow field and performance of low-specific-speed centrifugal pump, the flow field in the pump with different blade outlet angles 32.5°and 39° ...In order to analyze the influence of blade outlet angle on inner flow field and performance of low-specific-speed centrifugal pump, the flow field in the pump with different blade outlet angles 32.5°and 39° was numerically calculated. The external performance experiment was also carried out on the pump. Based on SIMPLEC algorithm, time-average N-S equation and the rectified k-ε turbulent model were adopted during the process of computation. The distributions of velocity and pressure in pumps with different blade outlet angles were obtained by calculation. The numerical results show that backflow areas exist in the two impellers, while the inner flow has a little improvement in the impeller with larger blade outlet angle. Blade outlet angle has a certain influence on the static pressure near the long-blade leading edge and tongue, but it has little influence on the distribution of static pressure in the passages of impeller. The experiment results show that the low-specific-speed centrifugal pump with larger blade outlet angle has better hydraulic performance.展开更多
Solenoid valve is one of the executive parts of weft insertion control system. According to the response characteristics of the solenoid valve, an improved design becomes a necessity. Firstly, the numerical model was ...Solenoid valve is one of the executive parts of weft insertion control system. According to the response characteristics of the solenoid valve, an improved design becomes a necessity. Firstly, the numerical model was established after analyzing the solenoid valve during its start-up and shut-down. Comparing the simulation data with the practical data, it is verified that the numerical simulation model has a high feasibility. Secondly, excitation voltage and spring pre-compression were adjusted respectively, and the response rules after adjusting were investigated. The research of the study shows: the response time tends to be inverse proportional to the excitation voltage during start-up, and it becomes a constant value with the increase of the excitation voltage; the response time is proportional to the spring pre-compression when the solenoid valve starts up, it is inverse proportional to spring pre-compression when the solenoid valve shuts down. And the total response time is a constant value with the increase of the spring pre-compression. Therefore, the value of the excitation voltage and the spring pre-compression should be selected when the curve is becoming flatten. The results of the research can provide the reference to the further development of the solenoid valve.展开更多
Interaction between rotor and struts has great effect on the performance of small axial fan systems. The small axial fan systems are selected as the studied objects in this paper, and four square struts are downstream...Interaction between rotor and struts has great effect on the performance of small axial fan systems. The small axial fan systems are selected as the studied objects in this paper, and four square struts are downstream of the rotor. The cross section of the struts is changed to the cylindrical shapes for the investigation: one is in the same hy- draulic diameter as the square struts and another one is in the same cross section as the square struts. Influence of the shape of the struts on the static pressure characteristics, the internal flow and the sound emission of the small axial fans are studied. Standard K-s turbulence model and SIMPLE algorithm are applied in the calculation of the steady fluid field, and the curves of the pressure rising against the flow rate are obtained, which demonstrates that the simulation results are in nice consistence with the experimental data. The steady calculation results are set as the initial field in the unsteady calculation. Large eddy simulation and PISO algorithm are used in the transient calculation, and the Ffowcs Williams-Hawkings model is introduced to predict the sound level at the eight monitoring points. The research results show that: the static pressure coefficients of the fan with cylindrical struts increase by about 25% compared to the fan with square strum, and the efficiencies increase by about 28.6%. The research provides a theoretical guide for shape optimization and noise reduction of small axial fan with struts.展开更多
To investigate the influence of impeller type on the performance and inner flow of centrifugal pump, the numeri- cal simulation and experimental research were carried out on the same centrifugal pump with straight-bla...To investigate the influence of impeller type on the performance and inner flow of centrifugal pump, the numeri- cal simulation and experimental research were carried out on the same centrifugal pump with straight-blade and curved-blade open impeller. Based on SIMPLEC algorithm, time-averaged N-S equation and the standard k-e turbulence model, the numerical results are obtained. The pressure distribution in the different type impellers is uniform, while the low pressure area in straight-blade inlet is larger. The vortexes in the passage of impeller exist in both cases. Relative to curved-blade impeller, there are larger vortexes in most of the flow passages except the passage near the tongue in straight-blade impeller. Also some small backflow regions are found at the blade inlet of two impellers. The characteristic curves achieved by numerical simulation basieaUy agree with those by experiment, and straight-blade open impeller centrifugal pump has a better hydraulic performance.展开更多
基金This project is supported by National Natural Science Foundation of China(No.50575209).
文摘The filling and exhausting processes in a pneumatic system are involved with many factors, and numerical solutions of many partial differential equations are always adapted in the study of those processes, which have been proved to be troublesome and less intuitive. Analytical solutions based on loss-less tube model and average friction tube model are found respectively by using fluid net theory, and they fit the experimental results well. The research work shows that: Fluid net theory can be used to solve the analytical solution of filling and exhausting processes of pneumatic system, and the result of loss-less tube model is close to that of average friction model, so loss-less tube model is recommended since it is simpler, and the difference between filling time and exhausting time is determined by initial and final pressures, the volume of container and the section area of tube, and has nothing to do with the length of the tube.
基金supported by National Natural Science Foundation of China (Grant No.50575209)
文摘The condensation in pneumatic system is a complex physical phenomenon dependant upon status variation and phase transitions,which are related to the parameters of the compressed air,atmospheric conditions and the dimensions of the pneumatic components.Up to now,general research method for this problem is to calculate the status variation and movement quantity by numerical simulation and experiment directly.The comprehensive parameters composed of several different effect factors are rarely used to study the condensation.The composed components and the working conditions of each cylinder are different,a large number of experiments and complex calculations are necessary to determine the condensation.Additionally,the transferability of the determined results is poor.In this paper,the charging and discharging systems of serials cylinder with different structure parameters are studied.The condensation of the systems is observed and the effects of the structure parameters on condensation are analyzed.The changing trends of relative humidity,natural frequency and average speed against the structural parameters of the components during discharge of the pneumatic systems are analyzed.Three comprehensive parameters used to analyze and determine condensation composed by structure parameters of components are proposed,namely,the ratio of the effective area of the discharge tube and the container volume,the square root of the effective area of the discharge tube divided by the product of the container volume and the length of the discharge tube,and the discharge dimensionless tube-volume.The experimental results show that these comprehensive parameters can be used to quantitatively determine whether internal,external or zero condensation occurs in a pneumatic system,and can be also used to quantitatively analyze the experimental data of condensation in pneumatic systems directly.At the same time,the effect factors are too much and the effect relationships are very complex,which causes that the conclusions can't be put forward by using single effect factor in experimental data processing individually.The three obtained comprehensive parameters can be used to resolve the above problem.The proposed parameters can also resolve the problem of poor transferability in determining the state of condensation in pneumatic systems,and provide a novel method for the further study of condensation theory.
基金supported by the National Natural Science Foundation of China granted No.51276172
文摘To investigate the unsteady flow characteristics in centrifugal pump, the flow field in a low-specific-speed centri- fugal pump with complex impeller is numerically simulated under different conditions. The RNG r-e turbulence model and sliding mesh are adopted during the process of computation. The results show that the interaction be- tween impeller and volute results in the unstable flow of the fluid, which causes the uneven distribution of pres- sure fluctuations around the circumference of volute. Besides the main frequency and its multiple frequency of pressure fluctuations in the centrifugal pump, the frequency caused by the long blades of complex impeller also plays a dominant role in the low-frequency areas. Furthermore, there exists biggish fluctuation phenomenon near the tongue. The composition of static pressure fluctuations frequency on the volute wall and blade outlet is similar except that the fluctuation amplitude near the volute wall reduces. In general, the different flow rates mainly have influence on the amplitude of fluctuation frequency in the pump, while have little effect on the frequency compo- sition.
基金supported by grants from the National Natural Science Foundation of China(No.51006090)the Major Special Project of Technology Office in Zhejiang Province(No.2011C11073,No.2011C16038)
文摘Aerodynamic performance of an axial flow fan is closely related to its tip clearance leakage flow. In this paper, the hot-wire anemometer is used to measure the three dimensional mean velocity near the blade tips. Moreover, the filtered N-S equations with finite volume method and RNG k-s turbulence model are adopted to carry out the steady simulation calculation of several fans that differ only in tip flange shape and number. The large eddy simulation and the FW-H noise models are adopted to carry out the unsteady numerical calculation and aerodynamic noise prediction. The results of simulation calculation agree roughly with that of tests, which proves the numerical calculation method is feasible.The effects of tip flange shapes and numbers on the blade tip vortex structure and the characteristics are analyzed. The results show that tip flange of the fan has a certain influence on the characteristics of the fan. The maximum efficiencies for the fans with tip flanges are shifted towards partial flow with respect to the design point of the dattun fan. Furthermore, the noise characteristics for the fans with tip flanges have become more deteriorated than that for the datum fan. Tip flange contributes to forming tip vortex shedding and the effect of the half-cylinder tip flange on tip vortex shedding is obvious. There is a distinct rela- tionship between the characteristics of the fan and tip vortex shedding.The research results provide the profitable reference for the internal flow mechanism of the performance optimization of small axial flow fans.
基金supported by grants from the National Natural Science Foundation of China (No.51076144)the Major Special Project of Technology Office in Zhejiang Province (No.2011C11073, No.2011C16038)
文摘To improve the aerodynamic performance of small axial flow fan, in this paper the design of a small axial flow fan with splitter blades is studied. The RNG k-e turbulence model and SIMPLE algorithm were applied to the steady simulation calculation of the flow field, and its result was used as the initial field of the large eddy simulation to calculate the unsteady pressure field. The FW-H noise model was adopted to predict aerodynamic noise in the six monitoring points. Fast Fourier transform algorithm was applied to process the pressure signal. Experiment of noise testing was done to further investigate the aerodynamic noise of fans. And then the results obtained from the numerical simulation and experiment were described and analyzed. The results show that the static characteristics of small axial fan with splitter blades are similar with the prototype fan, and the static characteristics are improved within a certain range of flux. The power spectral density at the six monitoring points of small axial flow fan with splitter blades have decreased to some extent. The experimental results show sound pressure level of new fan has reduced in most frequency bands by comparing with prototype fan. The research results will provide a proof for parameter optimization and noise prediction of small axial flow fans with high performance.
基金supported by National Natural Science Foundation of China No.51276172Public Welfare Technology Application Projects of Zhejiang Province NO.2015C31002Open Foundation of Zhejiang Provincial Top Key Academic Discipline of Mechanical Engineering and ZSTUMEOIA04 and 2013TD18
文摘Effects of the inlet guide vanes on the static characteristics, aerodynamic noise and internal flow characteristics of a small axial flow fan are studied in this work. The inlet guide vanes with different outlet angle are designed, which are mounted on the casing and located at the upstream of the impeller of the prototype fan. Both steady and unsteady flow simulations arc performed. The steady flow is simulated by the calculations of Navier-Stokes equa- tions coupled with RNG k-epsilon turbulence model, while the unsteady flow is computed with large eddy simu- lation. According to the theoretical analysis, the inlet guide vanes with outlet angle of 60° are regarded as the op- timal inlet guide vanes. The static characteristic experiment is carried out in a standard test rig and the aerody- namic noise is tested in a semi-anechoic room. Then, performances of the fan with optimal inlet guide vanes are compared with those of the prototype fan. The results show that there is reasonable agreement between the simu- lation results and the experimental data. It is found that the static characteristics of small axial flow fan is im- proved obviously after installing the optimal inlet guide vanes. Meanwhile, the optimal inlet guide vanes have effect on reducing noise at the near field, but have little effect on the noise at the far field.
基金supported by National Natural Science Foundation of China granted No.50976105,No.51276172Zhejiang Provincial Natural Science Foundation Granted No.R1100530
文摘In order to analyze the influence of blade outlet angle on inner flow field and performance of low-specific-speed centrifugal pump, the flow field in the pump with different blade outlet angles 32.5°and 39° was numerically calculated. The external performance experiment was also carried out on the pump. Based on SIMPLEC algorithm, time-average N-S equation and the rectified k-ε turbulent model were adopted during the process of computation. The distributions of velocity and pressure in pumps with different blade outlet angles were obtained by calculation. The numerical results show that backflow areas exist in the two impellers, while the inner flow has a little improvement in the impeller with larger blade outlet angle. Blade outlet angle has a certain influence on the static pressure near the long-blade leading edge and tongue, but it has little influence on the distribution of static pressure in the passages of impeller. The experiment results show that the low-specific-speed centrifugal pump with larger blade outlet angle has better hydraulic performance.
基金supported by the National Natural Science Foundation of China(No.51006090)
文摘Solenoid valve is one of the executive parts of weft insertion control system. According to the response characteristics of the solenoid valve, an improved design becomes a necessity. Firstly, the numerical model was established after analyzing the solenoid valve during its start-up and shut-down. Comparing the simulation data with the practical data, it is verified that the numerical simulation model has a high feasibility. Secondly, excitation voltage and spring pre-compression were adjusted respectively, and the response rules after adjusting were investigated. The research of the study shows: the response time tends to be inverse proportional to the excitation voltage during start-up, and it becomes a constant value with the increase of the excitation voltage; the response time is proportional to the spring pre-compression when the solenoid valve starts up, it is inverse proportional to spring pre-compression when the solenoid valve shuts down. And the total response time is a constant value with the increase of the spring pre-compression. Therefore, the value of the excitation voltage and the spring pre-compression should be selected when the curve is becoming flatten. The results of the research can provide the reference to the further development of the solenoid valve.
基金supported by National Natural Science Foundation of China(No.51276172)National Science and Technology Support Project(No.2013BAF05B01)etc
文摘Interaction between rotor and struts has great effect on the performance of small axial fan systems. The small axial fan systems are selected as the studied objects in this paper, and four square struts are downstream of the rotor. The cross section of the struts is changed to the cylindrical shapes for the investigation: one is in the same hy- draulic diameter as the square struts and another one is in the same cross section as the square struts. Influence of the shape of the struts on the static pressure characteristics, the internal flow and the sound emission of the small axial fans are studied. Standard K-s turbulence model and SIMPLE algorithm are applied in the calculation of the steady fluid field, and the curves of the pressure rising against the flow rate are obtained, which demonstrates that the simulation results are in nice consistence with the experimental data. The steady calculation results are set as the initial field in the unsteady calculation. Large eddy simulation and PISO algorithm are used in the transient calculation, and the Ffowcs Williams-Hawkings model is introduced to predict the sound level at the eight monitoring points. The research results show that: the static pressure coefficients of the fan with cylindrical struts increase by about 25% compared to the fan with square strum, and the efficiencies increase by about 28.6%. The research provides a theoretical guide for shape optimization and noise reduction of small axial fan with struts.
基金supported by National Natural Science Foundation of China granted No.51276172,No.50976105
文摘To investigate the influence of impeller type on the performance and inner flow of centrifugal pump, the numeri- cal simulation and experimental research were carried out on the same centrifugal pump with straight-blade and curved-blade open impeller. Based on SIMPLEC algorithm, time-averaged N-S equation and the standard k-e turbulence model, the numerical results are obtained. The pressure distribution in the different type impellers is uniform, while the low pressure area in straight-blade inlet is larger. The vortexes in the passage of impeller exist in both cases. Relative to curved-blade impeller, there are larger vortexes in most of the flow passages except the passage near the tongue in straight-blade impeller. Also some small backflow regions are found at the blade inlet of two impellers. The characteristic curves achieved by numerical simulation basieaUy agree with those by experiment, and straight-blade open impeller centrifugal pump has a better hydraulic performance.