After publication of this article1,it was brought to our at-tention that the mathematical expressions‘‰’were mis-takenly replaced by‘%’for salinities.Details are listed below.1.In the last sentence in abstract,“...After publication of this article1,it was brought to our at-tention that the mathematical expressions‘‰’were mis-takenly replaced by‘%’for salinities.Details are listed below.1.In the last sentence in abstract,“approximately 0.1℃and 0.5%”should be“approximately 0.1℃and 0.5‰”.展开更多
The Brillouin scattering spectrum has been used to investigate the properties of a liquid medium.Here,we propose an improved method based on the double-edge technique to obtain the Brillouin spectrum of a liquid.We ca...The Brillouin scattering spectrum has been used to investigate the properties of a liquid medium.Here,we propose an improved method based on the double-edge technique to obtain the Brillouin spectrum of a liquid.We calculated the transmission ratios and deduced the Brillouin shift and linewidth to construct the Brillouin spectrum by extracting the Brillouin edge signal through filtered double-edge data.We built a detection system to test the performance of this method and measured the Brillouin spectrum for distilled water at different temperatures and compared it with the theoretical prediction.The observed difference between the experimental and theoretical values for Brillouin shift and linewidth is less than 4.3 MHz and 3.2 MHz,respectively.Moreover,based on the double-edge technique,the accuracy of the extracted temperatures and salinity is approximately 0.1°C and 0.5‰,respectively,indicating significant potential for application in water detection and oceanography.展开更多
文摘After publication of this article1,it was brought to our at-tention that the mathematical expressions‘‰’were mis-takenly replaced by‘%’for salinities.Details are listed below.1.In the last sentence in abstract,“approximately 0.1℃and 0.5%”should be“approximately 0.1℃and 0.5‰”.
基金supported by the National Natural Science Foundation of China (Grant No. 62175072, No. 62175072 and No. 12074209)the Open Project of State Key Laboratory of Low-Dimensional Quantum Physics (Grant No. KF202008)support from International Postdoctoral Exchange Fellowship Program (Talent-Introduction Program)。
文摘The Brillouin scattering spectrum has been used to investigate the properties of a liquid medium.Here,we propose an improved method based on the double-edge technique to obtain the Brillouin spectrum of a liquid.We calculated the transmission ratios and deduced the Brillouin shift and linewidth to construct the Brillouin spectrum by extracting the Brillouin edge signal through filtered double-edge data.We built a detection system to test the performance of this method and measured the Brillouin spectrum for distilled water at different temperatures and compared it with the theoretical prediction.The observed difference between the experimental and theoretical values for Brillouin shift and linewidth is less than 4.3 MHz and 3.2 MHz,respectively.Moreover,based on the double-edge technique,the accuracy of the extracted temperatures and salinity is approximately 0.1°C and 0.5‰,respectively,indicating significant potential for application in water detection and oceanography.