Global variance reduction is a bottleneck in Monte Carlo shielding calculations.The global variance reduction problem requires that the statistical error of the entire space is uniform.This study proposed a grid-AIS m...Global variance reduction is a bottleneck in Monte Carlo shielding calculations.The global variance reduction problem requires that the statistical error of the entire space is uniform.This study proposed a grid-AIS method for the global variance reduction problem based on the AIS method,which was implemented in the Monte Carlo program MCShield.The proposed method was validated using the VENUS-Ⅲ international benchmark problem and a self-shielding calculation example.The results from the VENUS-Ⅲ benchmark problem showed that the grid-AIS method achieved a significant reduction in the variance of the statistical errors of the MESH grids,decreasing from 1.08×10^(-2) to 3.84×10^(-3),representing a 64.00% reduction.This demonstrates that the grid-AIS method is effective in addressing global issues.The results of the selfshielding calculation demonstrate that the grid-AIS method produced accurate computational results.Moreover,the grid-AIS method exhibited a computational efficiency approximately one order of magnitude higher than that of the AIS method and approximately two orders of magnitude higher than that of the conventional Monte Carlo method.展开更多
The rise in breast cancer diagnoses among Chinese women has necessitated the use of X-ray breast screening,which carries a radiation risk.This study aimed to provide a dosimetry protocol for the Chinese female populat...The rise in breast cancer diagnoses among Chinese women has necessitated the use of X-ray breast screening,which carries a radiation risk.This study aimed to provide a dosimetry protocol for the Chinese female population to replace the traditional standard that utilizes simplified breast models,for the accurate estimation of the mean glandular dose of a patient undergoing digital breast tomosynthesis(DBT).The first set of detailed Chinese female breast models and representative breast parameters was constructed.Considering backscatter radiation and computational efficiency,we improved the combination of these models and the Chinese reference adult female whole-body voxel phantom.Image acquisition for four commercial DBT systems that are widely employed in China was simulated using the Monte Carlo method to obtain the normalized glandular dose coefficients of DBT(D_(gN)^(DBT))and the glandular depth dose(D_(g)^(dep)(z))for different breast characteristics and X-ray spectra.We calculated a series of D_(gN)^(DBT) values for breasts with different percentage mass glandularities(5%,25%,50%,75%,and 100%)and compressed breast thicknesses(2,3,4,5,6,and 7 cm)at various tube potentials(25,28,30,32,35,and 49 kV)and target/filter combinations(W/Rh,W/Al,Mo/Mo,Rh/Rh,and Rh/Ag).The parameter dependence of the breast characteristics and beam conditions on D_(gN)^(DBT) in detailed breast models was investigated.The D_(gN)^(DBT) results were 14.6-51.0%lower than those of the traditional dosimetry standard in China.The difference in D_(gN)^(DBT) was mainly due to a decrease in the depth of the main energy deposition area caused by the glandular distribution along the depth direction.The results obtained in this study may be used to improve breast dosimetry in China and provide more detailed information on risk assessment during DBT.展开更多
AIM: To investigate whether autologous dendritic cell (DC)-cytokine-induced killer (CIK) cell therapy is able to improve the therapeutic efficacy of chemotherapy in colon cancer.
Intrinsic radiation of materials is one of the major backgrounds for many rare-event search experiments.Thus,the production of pure materials in an underground laboratory is a promising approach for eliminating cosmog...Intrinsic radiation of materials is one of the major backgrounds for many rare-event search experiments.Thus,the production of pure materials in an underground laboratory is a promising approach for eliminating cosmogenic radionuclides.In this paper,we demonstrate a procedure to evaluate the yields of cosmogenic radionuclides in copper and germanium in the second phase of the China Jinping Underground Laboratory.Our results show that for copper and germanium materials,the largest cosmogenic background comes from 3 H and57,58,60Co,and 3 H and 68Ge,respectively,which all have yields on the order of 10-7 kg-1 day-1.The corresponding radioactivities after 90 days pf exposure underground are estimated to be lower than 10-6μBq kg-1.展开更多
In designing a fixed-bed adsorber, it is vital to understand dynamic adsorption properties of the unit. Temperature is an important effect on adsorbent performance, as the dynamic adsorption coefficients tend to incre...In designing a fixed-bed adsorber, it is vital to understand dynamic adsorption properties of the unit. Temperature is an important effect on adsorbent performance, as the dynamic adsorption coefficients tend to increase with decreasing temperature. To minimize the volume of the fixed-bed adsorber, the dynamic adsorption characteristics of Xe were studied at 77 K by employing a variety of adsorbents under different operational conditions. The carbon molecular sieve performed better than that of activated carbon. Both operational conditions and the presence of gaseous impurities were found to affect the adsorption properties.展开更多
The broad-energy germanium(BEGe)detector,with the ability of background discrimination using pulse shape discrimination,is a competitive candidate for neutrinoless double beta decay(ovββ)experiments.In this paper,we...The broad-energy germanium(BEGe)detector,with the ability of background discrimination using pulse shape discrimination,is a competitive candidate for neutrinoless double beta decay(ovββ)experiments.In this paper,we report our measurements of key parameters for detector modeling in a commercial p-type BEGe detector.Point-like sources are used to investigate energy resolution and linearity of the detector.A cylindrical volume source is used for efficiency calibration.With an assembled device for source positioning and a collimated ^(133)Ba source,the detector is scanned to check its active volume.Using an^(241)Am point-like source,the dead layer thicknesses is measured at about 0.17 mm on the front and 1.18 mm on the side.The detector characterization is of importance for BEGe detectors to be used in the ovββ experiments at China JinPing underground Laboratory(CJPL).展开更多
Automatic conversion from a computer-aided design(CAD) model to Monte Carlo geometry is one of the most effective methods for large-scale and detailed Monte Carlo modeling. The CAD to Monte Carlo geometry converter(CM...Automatic conversion from a computer-aided design(CAD) model to Monte Carlo geometry is one of the most effective methods for large-scale and detailed Monte Carlo modeling. The CAD to Monte Carlo geometry converter(CMGC) is a newly developed conversion code based on the boundary representation to constructive solid geometry(BRep→CSG) conversion method. The goal of the conversion process in the CMGC is to generate an appropriate CSG representation to achieve highly efficient Monte Carlo simulations. We designed a complete solid decomposition scheme to split a complex solid into as few nonoverlapping simple sub-solids as possible. In the complete solid decomposition scheme, the complex solid is successively split by so-called direct, indirect, and auxiliary splitting surfaces. We defined the splitting edge and designed a method for determining the direct splitting surface based on the splitting edge, then provided a method for determining indirect and auxiliary splitting surfaces based on solid vertices. Only the sub-solids that contain concave boundary faces need to be supplemented with auxiliary surfaces because the solid is completely decomposed, which will reduce the redundancy in the CSG expression. After decomposition, these sub-solids are located on only one side of their natural and auxiliary surfaces;thus, each sub-solid can be described by the intersections of a series of half-spaces or geometrical primitives. The CMGC has a friendly graphical user interface and can convert a CAD model into geometry input files for several Monte Carlo codes. The reliability of the CMGC was evaluated by converting several complex models and calculating the relative volume errors. Moreover, JMCT was used to test the efficiency of the Monte Carlo simulation. The results showed that the converted models performed well in particle transport calculations.展开更多
AIM:To evaluate the feasibility,safety,and effectiveness of consecutive laparoscopic cholecystectomy(LC)plus splenectomy(LS)in liver cirrhosis patients.METHODS:From 2003 to 2013,17(group 1)patients with liver cirrhosi...AIM:To evaluate the feasibility,safety,and effectiveness of consecutive laparoscopic cholecystectomy(LC)plus splenectomy(LS)in liver cirrhosis patients.METHODS:From 2003 to 2013,17(group 1)patients with liver cirrhosis complicated by hypersplenism and symptomatic gallstones were treated with combined LC and LS,while 58(group 2)patients with liver cirrhosis and hypersplenism received LS alone.An additional 14(group 3)patients who received traditional open procedures during the same period were included as controls.Data were retrospectively collected and reviewed in regard to demographic characteristics and preoperative,intraoperative and postoperative features.Differences between the three groups were assessed by statistical analysis.RESULTS:The three groups showed no significant differences in the demographic characteristics or preoperative status.However,the patients treated with LC and LS required significantly longer operative time,shorter postoperative stay as well as shorter time of return to the first oral intake,and suffered less intraoperative blood loss as well as fewer postoperative surgical infections than the patients treated with traditional open procedures(group 1 vs group 3,P<0.05 for all).The patients treated with LC and LS showed no significant differences in the intraoperative and postoperative variables from those treated with LS alone(group 1 vs group 2).All patients showed significant improvements in the haematological responses(preoperative period vs postoperative period,P<0.05 for all).None of the patients treated with LC and LS presented with any gallstone-associated symptoms following discharge,while the patients treated with the traditional open procedures expressed complaints of discomfort related to their surgical incisions.CONCLUSION:Consecutive LC and LS is an appropriate treatment option for liver cirrhosis patients with gallstones and hypersplenism,especially for those with Child-Pugh A and B.展开更多
The Monte Carlo(MC)simulation is regarded as the gold standard for dose calculation in brachytherapy,but it consumes a large amount of computing resources.The development of heterogeneous computing makes it possible t...The Monte Carlo(MC)simulation is regarded as the gold standard for dose calculation in brachytherapy,but it consumes a large amount of computing resources.The development of heterogeneous computing makes it possible to substantially accelerate calculations with hardware accelerators.Accordingly,this study develops a fast MC tool,called THUBrachy,which can be accelerated by several types of hardware accelerators.THUBrachy can simulate photons with energy less than 3 MeV and considers all photon interactions in the energy range.It was benchmarked against the American Association of Physicists in Medicine Task Group No.43 Report using a water phantom and validated with Geant4 using a clinical case.A performance test was conducted using the clinical case,showing that a multicore central processing unit,Intel Xeon Phi,and graphics processing unit(GPU)can efficiently accelerate the simulation.GPU-accelerated THUBrachy is the fastest version,which is 200 times faster than the serial version and approximately 500 times faster than Geant4.The proposed tool shows great potential for fast and accurate dose calculations in clinical applications.展开更多
GnRH sterilization vaccines have been developed for various practical and clinical reasons. However, conjugation of GnRH peptide to carrier protein has many drawbacks, hampering the further commercialization of GnRH v...GnRH sterilization vaccines have been developed for various practical and clinical reasons. However, conjugation of GnRH peptide to carrier protein has many drawbacks, hampering the further commercialization of GnRH vaccines. In this study, a new nonconjugated GnRH vaccine, D-Lys6-GnRH-tandem-dimer peptide (TDK), emulsified in Specol adjuvant was investigated for its immunocastration efficacy in young male rats. Prepubertal male rats were randomly allocated into three groups (n = 12): control (no treatment), surgically castrated or immunized against 100 μg TDK in Specol adjuvant at 6 weeks of age (with a booster 8 weeks later). Blood samples (for antibody titers and hormone concentrations) were collected at 2-week intervals until rats were killed (18 weeks of age). Compared to intact controls, active immunization against TDK reduced (P〈 0.05) serum concentrations of testosterone, inhibin B, LH and FSH, prevented the onset of spermatogenesis at puberty. Furthermore, mRNA expressions of GnRH receptor, LH-β and FSH-β in the pituitary, LH receptor, FSH receptor, inhibin α, βA and βB subunit in the testes were decreased in immunocastrated rats compared to intact controls (P 〈 0.05). These results demonstrate for the first time that GnRH-tandem-dimer peptide emulsified in Specol is a promising veterinary sterilization medicine.展开更多
基金supported by the Platform Development Foundation of the China Institute for Radiation Protection(No.YP21030101)the National Natural Science Foundation of China(General Program)(Nos.12175114,U2167209)+1 种基金the National Key R&D Program of China(No.2021YFF0603600)the Tsinghua University Initiative Scientific Research Program(No.20211080081).
文摘Global variance reduction is a bottleneck in Monte Carlo shielding calculations.The global variance reduction problem requires that the statistical error of the entire space is uniform.This study proposed a grid-AIS method for the global variance reduction problem based on the AIS method,which was implemented in the Monte Carlo program MCShield.The proposed method was validated using the VENUS-Ⅲ international benchmark problem and a self-shielding calculation example.The results from the VENUS-Ⅲ benchmark problem showed that the grid-AIS method achieved a significant reduction in the variance of the statistical errors of the MESH grids,decreasing from 1.08×10^(-2) to 3.84×10^(-3),representing a 64.00% reduction.This demonstrates that the grid-AIS method is effective in addressing global issues.The results of the selfshielding calculation demonstrate that the grid-AIS method produced accurate computational results.Moreover,the grid-AIS method exhibited a computational efficiency approximately one order of magnitude higher than that of the AIS method and approximately two orders of magnitude higher than that of the conventional Monte Carlo method.
基金supported by the National Natural Science Foundation of China(Nos.U2167209 and 12175114)the National Key R&D Program of China(No.2021YFF0603600).
文摘The rise in breast cancer diagnoses among Chinese women has necessitated the use of X-ray breast screening,which carries a radiation risk.This study aimed to provide a dosimetry protocol for the Chinese female population to replace the traditional standard that utilizes simplified breast models,for the accurate estimation of the mean glandular dose of a patient undergoing digital breast tomosynthesis(DBT).The first set of detailed Chinese female breast models and representative breast parameters was constructed.Considering backscatter radiation and computational efficiency,we improved the combination of these models and the Chinese reference adult female whole-body voxel phantom.Image acquisition for four commercial DBT systems that are widely employed in China was simulated using the Monte Carlo method to obtain the normalized glandular dose coefficients of DBT(D_(gN)^(DBT))and the glandular depth dose(D_(g)^(dep)(z))for different breast characteristics and X-ray spectra.We calculated a series of D_(gN)^(DBT) values for breasts with different percentage mass glandularities(5%,25%,50%,75%,and 100%)and compressed breast thicknesses(2,3,4,5,6,and 7 cm)at various tube potentials(25,28,30,32,35,and 49 kV)and target/filter combinations(W/Rh,W/Al,Mo/Mo,Rh/Rh,and Rh/Ag).The parameter dependence of the breast characteristics and beam conditions on D_(gN)^(DBT) in detailed breast models was investigated.The D_(gN)^(DBT) results were 14.6-51.0%lower than those of the traditional dosimetry standard in China.The difference in D_(gN)^(DBT) was mainly due to a decrease in the depth of the main energy deposition area caused by the glandular distribution along the depth direction.The results obtained in this study may be used to improve breast dosimetry in China and provide more detailed information on risk assessment during DBT.
基金Supported by National Natural Science Foundation of China,No.31171427 and No.30971651 to Wang ZXNational Natural Science Foundation of China,No.30700974 to Cao JXPostdoctoral Foundation of China,No.20060400775 to Cao JX
文摘AIM: To investigate whether autologous dendritic cell (DC)-cytokine-induced killer (CIK) cell therapy is able to improve the therapeutic efficacy of chemotherapy in colon cancer.
基金supported by the National Natural Science Foundation of China(No.U1865205).
文摘Intrinsic radiation of materials is one of the major backgrounds for many rare-event search experiments.Thus,the production of pure materials in an underground laboratory is a promising approach for eliminating cosmogenic radionuclides.In this paper,we demonstrate a procedure to evaluate the yields of cosmogenic radionuclides in copper and germanium in the second phase of the China Jinping Underground Laboratory.Our results show that for copper and germanium materials,the largest cosmogenic background comes from 3 H and57,58,60Co,and 3 H and 68Ge,respectively,which all have yields on the order of 10-7 kg-1 day-1.The corresponding radioactivities after 90 days pf exposure underground are estimated to be lower than 10-6μBq kg-1.
基金supported by the National Natural Science Foundation of China(No.11405134)
文摘In designing a fixed-bed adsorber, it is vital to understand dynamic adsorption properties of the unit. Temperature is an important effect on adsorbent performance, as the dynamic adsorption coefficients tend to increase with decreasing temperature. To minimize the volume of the fixed-bed adsorber, the dynamic adsorption characteristics of Xe were studied at 77 K by employing a variety of adsorbents under different operational conditions. The carbon molecular sieve performed better than that of activated carbon. Both operational conditions and the presence of gaseous impurities were found to affect the adsorption properties.
基金supported by National Natural Science Foundation of China(Nos.11175099&11355001)Tsinghua University Initiative Scientific Research Program(Nos.20151080354&2014Z21016)
文摘The broad-energy germanium(BEGe)detector,with the ability of background discrimination using pulse shape discrimination,is a competitive candidate for neutrinoless double beta decay(ovββ)experiments.In this paper,we report our measurements of key parameters for detector modeling in a commercial p-type BEGe detector.Point-like sources are used to investigate energy resolution and linearity of the detector.A cylindrical volume source is used for efficiency calibration.With an assembled device for source positioning and a collimated ^(133)Ba source,the detector is scanned to check its active volume.Using an^(241)Am point-like source,the dead layer thicknesses is measured at about 0.17 mm on the front and 1.18 mm on the side.The detector characterization is of importance for BEGe detectors to be used in the ovββ experiments at China JinPing underground Laboratory(CJPL).
基金the National Natural Science Foundation of China(No.11805017)。
文摘Automatic conversion from a computer-aided design(CAD) model to Monte Carlo geometry is one of the most effective methods for large-scale and detailed Monte Carlo modeling. The CAD to Monte Carlo geometry converter(CMGC) is a newly developed conversion code based on the boundary representation to constructive solid geometry(BRep→CSG) conversion method. The goal of the conversion process in the CMGC is to generate an appropriate CSG representation to achieve highly efficient Monte Carlo simulations. We designed a complete solid decomposition scheme to split a complex solid into as few nonoverlapping simple sub-solids as possible. In the complete solid decomposition scheme, the complex solid is successively split by so-called direct, indirect, and auxiliary splitting surfaces. We defined the splitting edge and designed a method for determining the direct splitting surface based on the splitting edge, then provided a method for determining indirect and auxiliary splitting surfaces based on solid vertices. Only the sub-solids that contain concave boundary faces need to be supplemented with auxiliary surfaces because the solid is completely decomposed, which will reduce the redundancy in the CSG expression. After decomposition, these sub-solids are located on only one side of their natural and auxiliary surfaces;thus, each sub-solid can be described by the intersections of a series of half-spaces or geometrical primitives. The CMGC has a friendly graphical user interface and can convert a CAD model into geometry input files for several Monte Carlo codes. The reliability of the CMGC was evaluated by converting several complex models and calculating the relative volume errors. Moreover, JMCT was used to test the efficiency of the Monte Carlo simulation. The results showed that the converted models performed well in particle transport calculations.
基金Supported by Grant from the West China Hospital at Sichuan University
文摘AIM:To evaluate the feasibility,safety,and effectiveness of consecutive laparoscopic cholecystectomy(LC)plus splenectomy(LS)in liver cirrhosis patients.METHODS:From 2003 to 2013,17(group 1)patients with liver cirrhosis complicated by hypersplenism and symptomatic gallstones were treated with combined LC and LS,while 58(group 2)patients with liver cirrhosis and hypersplenism received LS alone.An additional 14(group 3)patients who received traditional open procedures during the same period were included as controls.Data were retrospectively collected and reviewed in regard to demographic characteristics and preoperative,intraoperative and postoperative features.Differences between the three groups were assessed by statistical analysis.RESULTS:The three groups showed no significant differences in the demographic characteristics or preoperative status.However,the patients treated with LC and LS required significantly longer operative time,shorter postoperative stay as well as shorter time of return to the first oral intake,and suffered less intraoperative blood loss as well as fewer postoperative surgical infections than the patients treated with traditional open procedures(group 1 vs group 3,P<0.05 for all).The patients treated with LC and LS showed no significant differences in the intraoperative and postoperative variables from those treated with LS alone(group 1 vs group 2).All patients showed significant improvements in the haematological responses(preoperative period vs postoperative period,P<0.05 for all).None of the patients treated with LC and LS presented with any gallstone-associated symptoms following discharge,while the patients treated with the traditional open procedures expressed complaints of discomfort related to their surgical incisions.CONCLUSION:Consecutive LC and LS is an appropriate treatment option for liver cirrhosis patients with gallstones and hypersplenism,especially for those with Child-Pugh A and B.
基金supported by the National Natural Science Foundation of China(No.11875036)。
文摘The Monte Carlo(MC)simulation is regarded as the gold standard for dose calculation in brachytherapy,but it consumes a large amount of computing resources.The development of heterogeneous computing makes it possible to substantially accelerate calculations with hardware accelerators.Accordingly,this study develops a fast MC tool,called THUBrachy,which can be accelerated by several types of hardware accelerators.THUBrachy can simulate photons with energy less than 3 MeV and considers all photon interactions in the energy range.It was benchmarked against the American Association of Physicists in Medicine Task Group No.43 Report using a water phantom and validated with Geant4 using a clinical case.A performance test was conducted using the clinical case,showing that a multicore central processing unit,Intel Xeon Phi,and graphics processing unit(GPU)can efficiently accelerate the simulation.GPU-accelerated THUBrachy is the fastest version,which is 200 times faster than the serial version and approximately 500 times faster than Geant4.The proposed tool shows great potential for fast and accurate dose calculations in clinical applications.
文摘GnRH sterilization vaccines have been developed for various practical and clinical reasons. However, conjugation of GnRH peptide to carrier protein has many drawbacks, hampering the further commercialization of GnRH vaccines. In this study, a new nonconjugated GnRH vaccine, D-Lys6-GnRH-tandem-dimer peptide (TDK), emulsified in Specol adjuvant was investigated for its immunocastration efficacy in young male rats. Prepubertal male rats were randomly allocated into three groups (n = 12): control (no treatment), surgically castrated or immunized against 100 μg TDK in Specol adjuvant at 6 weeks of age (with a booster 8 weeks later). Blood samples (for antibody titers and hormone concentrations) were collected at 2-week intervals until rats were killed (18 weeks of age). Compared to intact controls, active immunization against TDK reduced (P〈 0.05) serum concentrations of testosterone, inhibin B, LH and FSH, prevented the onset of spermatogenesis at puberty. Furthermore, mRNA expressions of GnRH receptor, LH-β and FSH-β in the pituitary, LH receptor, FSH receptor, inhibin α, βA and βB subunit in the testes were decreased in immunocastrated rats compared to intact controls (P 〈 0.05). These results demonstrate for the first time that GnRH-tandem-dimer peptide emulsified in Specol is a promising veterinary sterilization medicine.