Hydrogel scaffolds have numerous potential applications in the tissue engineering field.However,tough hydrogel scaffolds implanted in vivo are seldom reported because it is difficult to balance biocompatibility and hi...Hydrogel scaffolds have numerous potential applications in the tissue engineering field.However,tough hydrogel scaffolds implanted in vivo are seldom reported because it is difficult to balance biocompatibility and high mechanical properties.Inspired by Chinese ramen,we propose a universal fabricating method(printing-P,training-T,cross-linking-C,PTC&PCT)for tough hydrogel scaffolds to fill this gap.First,3D printing fabricates a hydrogel scaffold with desired structures(P).Then,the scaffold could have extraordinarily high mechanical properties and functional surface structure by cycle mechanical training with salting-out assistance(T).Finally,the training results are fixed by photo-cross-linking processing(C).The tough gelatin hydrogel scaffolds exhibit excellent tensile strength of 6.66 MPa(622-fold untreated)and have excellent biocompatibility.Furthermore,this scaffold possesses functional surface structures from nanometer to micron to millimeter,which can efficiently induce directional cell growth.Interestingly,this strategy can produce bionic human tissue with mechanical properties of 10 kPa-10 MPa by changing the type of salt,and many hydrogels,such as gelatin and silk,could be improved with PTC or PCT strategies.Animal experiments show that this scaffold can effectively promote the new generation of muscle fibers,blood vessels,and nerves within 4 weeks,prompting the rapid regeneration of large-volume muscle loss injuries.展开更多
Dielectronic recombination is an important process in high temperature plasmas. In the present work, the KLn (n=L, M, N and O) DR resonance strengths of He-like to O-like xenon ions are measured at the Shanghai elec...Dielectronic recombination is an important process in high temperature plasmas. In the present work, the KLn (n=L, M, N and O) DR resonance strengths of He-like to O-like xenon ions are measured at the Shanghai electron beam ion trap using a fast electron beam energy scanning method. The experiment uncertainty reaches about 6% with significant improvement of statistics. A relativistic configuration interaction calculation is also made. Theoretical results agree with the experiment results within 15% in most cases.展开更多
The apoptosis of lens epithehal cells has been proposed as the common basis of cataract formation, with oxidative stress as the major cause. This study was performed to investigate the protective effect of the herbal ...The apoptosis of lens epithehal cells has been proposed as the common basis of cataract formation, with oxidative stress as the major cause. This study was performed to investigate the protective effect of the herbal constituent parthenolide against oxidative stress-induced apoptosis of human lens epithelial (HLE) cells and the possible molecular mechanisms involved. HLE cells (SRA01-04) were incubated with 50 μM H2O2 in the absence or presence of different doses of parthenolide (10, 20 and 50 μM). To study apoptosis, the cells were assessed by morphologic examination and Annexin V-propidium iodide double staining flow cytometry; to investigate the underlying molecular mechanisms, the expression of caspase-3 and caspase-9 were assayed by Western blot and quantitative RT-PCR, and the activities of caspase-3 and caspase-9 were measured by a Chemicon caspase colorimetric activity assay kit. Stimulated with H202 for 18 h, a high fraction of riLE cells underwent apoptosis, while in the presence ofparthenolide of different concentrations, dose-dependent blocking of HLE cell apoptosis was observed. The expression of caspase-3 and caspase-9 induced by H202 in HLE cells was significantly reduced by parthenolide both at the protein and mRNA levels, and the activation ofcaspase-3 and caspase-9 was also suppressed by parthenolide in a dose-dependent manner. In conclusion, parthenolide prevents HLE cells from oxidative stress-induced apoptosis through inhibition of the activation ofcaspase-3 and caspase-9, suggesting a potential protective effect against cataract formation.展开更多
AIM: To compare the short-term visual outcomes, residual refractive cylinder, and rotation stability after Tecnis toric intraocular lens(IOL) implantation during femtosecond laserassisted cataract surgery(Femto phaco)...AIM: To compare the short-term visual outcomes, residual refractive cylinder, and rotation stability after Tecnis toric intraocular lens(IOL) implantation during femtosecond laserassisted cataract surgery(Femto phaco) and conventional phacoemulsification surgery(Conventional phaco).METHODS: In a prospective cohort study, Conventional phaco and Femto phaco(anterior capsulotomy and lens fragmentation by a femtosecond laser) with Tecnis toric IOL implantation were performed in 40 eyes from 36 patients and 37 eyes from 33 patients, respectively. The uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), and manifest refraction were assessed during 1 d, 1 wk, and 1 mo follow-ups. The orientation of the Tecnis Toric IOL was evaluated during 1 wk and 1 mo follow-ups.RESULTS: There were no significant differences in UDCA or CDVA between two groups at 1 mo postoperatively, though relatively more subjects had UDVA values of 20/25 or better in Femto phaco group than in the Conventional group(P>0.05). A lower but not significantly lower rate of having more than 5° of IOL rotation was observed in Femto phaco group at the 1-month follow-up, while a significant lower rate of residual astigmatism of ≤1 D was observed in Femto phaco group.CONCLUSION: The Femto phaco group has significantly more subjects with the residual astigmatism of ≤1 D, but there are no significant differences in rotation stability and visual outcomes as compared with the Conventional phaco group after the application of the Tecnis toric IOL in this cohort.展开更多
·AIM: To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs). ...·AIM: To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs). ·METHODS: Tecnis ZMA00, Tecnis ZA9003 or Akreos Adapt IOLs were bilaterally implanted in 180 eyes from 90 patients. The following parameters were assessed 3 months postoperatively: monocular and binocular uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) for distance, intermediate and near, spherical aberration (SA), contrast and glare sensitivity, near point refractive power, uncorrected and best corrected near stereoscopic acuity (NSA). Patient satisfaction was assessed by a questionnaire. ·RESULTS:Threemonthspostoperatively,themonocular and binocular UCVA and DCVA at near of Tecnis ZMA00 were significantly better than other two groups. The mean SA for 5.0mm optical zone in Tecnis ZMA00 and Tecnis ZA9003 was significantly lower than that in Akreos Adapt. Mean contrast sensitivity and glare sensitivity were better for Tecnis ZA9003 group than for other two groups. Patients with Tecnis ZMA00 had higher monocular and binocular near point refractive power and uncorrected NSA than monofocal groups. The patients in Tecnis ZMA00 had higher mean values for halo compared with other two groups. ·CONCLUSION: Tecnis ZMA00 provided better near VA and uncorrected NSA and higher near point refractive power than monofocal IOLs and patients were spectacle independent. The IOLs with Tecnis aspheric design improved contrast and glare sensitivity. Patients with Tecnis ZMA00 reported more disturbances on visual phenomena of halo. ·展开更多
基金supported by the Innovative Research Group Project of the National Natural Science Foundation of China(T2121004)Key Programme(52235007)National Outstanding Youth Foundation of China(52325504).
文摘Hydrogel scaffolds have numerous potential applications in the tissue engineering field.However,tough hydrogel scaffolds implanted in vivo are seldom reported because it is difficult to balance biocompatibility and high mechanical properties.Inspired by Chinese ramen,we propose a universal fabricating method(printing-P,training-T,cross-linking-C,PTC&PCT)for tough hydrogel scaffolds to fill this gap.First,3D printing fabricates a hydrogel scaffold with desired structures(P).Then,the scaffold could have extraordinarily high mechanical properties and functional surface structure by cycle mechanical training with salting-out assistance(T).Finally,the training results are fixed by photo-cross-linking processing(C).The tough gelatin hydrogel scaffolds exhibit excellent tensile strength of 6.66 MPa(622-fold untreated)and have excellent biocompatibility.Furthermore,this scaffold possesses functional surface structures from nanometer to micron to millimeter,which can efficiently induce directional cell growth.Interestingly,this strategy can produce bionic human tissue with mechanical properties of 10 kPa-10 MPa by changing the type of salt,and many hydrogels,such as gelatin and silk,could be improved with PTC or PCT strategies.Animal experiments show that this scaffold can effectively promote the new generation of muscle fibers,blood vessels,and nerves within 4 weeks,prompting the rapid regeneration of large-volume muscle loss injuries.
基金supported by the National Key Research and Development Program of China under Grant No.2017YFA0402300
文摘Dielectronic recombination is an important process in high temperature plasmas. In the present work, the KLn (n=L, M, N and O) DR resonance strengths of He-like to O-like xenon ions are measured at the Shanghai electron beam ion trap using a fast electron beam energy scanning method. The experiment uncertainty reaches about 6% with significant improvement of statistics. A relativistic configuration interaction calculation is also made. Theoretical results agree with the experiment results within 15% in most cases.
基金supported by National Natural Science Foundation of China(No.30471538)Traditional Chinese Medicine Foundation of Zhejiang province(No.2005C086).
文摘The apoptosis of lens epithehal cells has been proposed as the common basis of cataract formation, with oxidative stress as the major cause. This study was performed to investigate the protective effect of the herbal constituent parthenolide against oxidative stress-induced apoptosis of human lens epithelial (HLE) cells and the possible molecular mechanisms involved. HLE cells (SRA01-04) were incubated with 50 μM H2O2 in the absence or presence of different doses of parthenolide (10, 20 and 50 μM). To study apoptosis, the cells were assessed by morphologic examination and Annexin V-propidium iodide double staining flow cytometry; to investigate the underlying molecular mechanisms, the expression of caspase-3 and caspase-9 were assayed by Western blot and quantitative RT-PCR, and the activities of caspase-3 and caspase-9 were measured by a Chemicon caspase colorimetric activity assay kit. Stimulated with H202 for 18 h, a high fraction of riLE cells underwent apoptosis, while in the presence ofparthenolide of different concentrations, dose-dependent blocking of HLE cell apoptosis was observed. The expression of caspase-3 and caspase-9 induced by H202 in HLE cells was significantly reduced by parthenolide both at the protein and mRNA levels, and the activation ofcaspase-3 and caspase-9 was also suppressed by parthenolide in a dose-dependent manner. In conclusion, parthenolide prevents HLE cells from oxidative stress-induced apoptosis through inhibition of the activation ofcaspase-3 and caspase-9, suggesting a potential protective effect against cataract formation.
基金Supported by Zhejiang Province Key Research and Development Program(No.2015C03042)
文摘AIM: To compare the short-term visual outcomes, residual refractive cylinder, and rotation stability after Tecnis toric intraocular lens(IOL) implantation during femtosecond laserassisted cataract surgery(Femto phaco) and conventional phacoemulsification surgery(Conventional phaco).METHODS: In a prospective cohort study, Conventional phaco and Femto phaco(anterior capsulotomy and lens fragmentation by a femtosecond laser) with Tecnis toric IOL implantation were performed in 40 eyes from 36 patients and 37 eyes from 33 patients, respectively. The uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), and manifest refraction were assessed during 1 d, 1 wk, and 1 mo follow-ups. The orientation of the Tecnis Toric IOL was evaluated during 1 wk and 1 mo follow-ups.RESULTS: There were no significant differences in UDCA or CDVA between two groups at 1 mo postoperatively, though relatively more subjects had UDVA values of 20/25 or better in Femto phaco group than in the Conventional group(P>0.05). A lower but not significantly lower rate of having more than 5° of IOL rotation was observed in Femto phaco group at the 1-month follow-up, while a significant lower rate of residual astigmatism of ≤1 D was observed in Femto phaco group.CONCLUSION: The Femto phaco group has significantly more subjects with the residual astigmatism of ≤1 D, but there are no significant differences in rotation stability and visual outcomes as compared with the Conventional phaco group after the application of the Tecnis toric IOL in this cohort.
基金Zhejiang Key Innovation Team Project(No. 2009R50039)Doctoral Fund of Ministry of Education of China (No: 20100101120135)Key Lab Fund of Zhejiang Province, China (No. 2011E10006)
文摘·AIM: To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs). ·METHODS: Tecnis ZMA00, Tecnis ZA9003 or Akreos Adapt IOLs were bilaterally implanted in 180 eyes from 90 patients. The following parameters were assessed 3 months postoperatively: monocular and binocular uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) for distance, intermediate and near, spherical aberration (SA), contrast and glare sensitivity, near point refractive power, uncorrected and best corrected near stereoscopic acuity (NSA). Patient satisfaction was assessed by a questionnaire. ·RESULTS:Threemonthspostoperatively,themonocular and binocular UCVA and DCVA at near of Tecnis ZMA00 were significantly better than other two groups. The mean SA for 5.0mm optical zone in Tecnis ZMA00 and Tecnis ZA9003 was significantly lower than that in Akreos Adapt. Mean contrast sensitivity and glare sensitivity were better for Tecnis ZA9003 group than for other two groups. Patients with Tecnis ZMA00 had higher monocular and binocular near point refractive power and uncorrected NSA than monofocal groups. The patients in Tecnis ZMA00 had higher mean values for halo compared with other two groups. ·CONCLUSION: Tecnis ZMA00 provided better near VA and uncorrected NSA and higher near point refractive power than monofocal IOLs and patients were spectacle independent. The IOLs with Tecnis aspheric design improved contrast and glare sensitivity. Patients with Tecnis ZMA00 reported more disturbances on visual phenomena of halo. ·