This study was aimed to investigate the effects of hydrothermal aging, propene and SO<sub>2</sub> poisoning on the ammonia-selective catalytic reduction (NH<sub>3</sub>-SCR) performance of both...This study was aimed to investigate the effects of hydrothermal aging, propene and SO<sub>2</sub> poisoning on the ammonia-selective catalytic reduction (NH<sub>3</sub>-SCR) performance of both Cu-SAPO-34 and Cu-ZSM-5. The catalytic activities of fresh, aged and poisoned samples were tested in ammonia-selective catalytic reduction (NH<sub>3</sub>-SCR) of NO<sub>x</sub> conditions. The XRD, TG and N<sub>2</sub>-desorption results showed that the structures of the Cu-SAPO-34 and Cu-ZSM-5 remained intact after 750˚C hydrothermally aged, SO<sub>2</sub> and propene poisoned. After hydrothermal aging at 750˚C for 12 h, the NO reduction performance of Cu-ZSM-5 was significantly reduced at lower temperatures, while that of Cu-SAPO-34 was less affected. Moreover, Cu-SAPO-34 catalyst showed high NO conversion with SO<sub>2</sub> or propene compared to Cu-ZSM-5. However, Cu-ZSM-5 showed a larger drop in catalytic activity with SO<sub>2</sub> or propene compared to Cu-SAPO-34 catalyst. The H<sub>2</sub>-TPR results showed that Cu<sup>2 </sup> ions could be reduced to Cu<sup> </sup> and Cu<sup>0</sup> for Cu-ZSM-5, while no significant transformation of copper species was observed for Cu-SAPO-34. Meanwhile, the UV-vis DRS results showed that CuO species were formed in Cu-ZSM-5, while little changes were observed for the Cu-SAPO-34. Cu-SAPO-34 showed high sulfur and hydrocarbon poison resistance compared to Cu-ZSM-5. In summary, Cu-SAPO-34 with small-pore zeolite showed higher hydrothermal stability and better hydrocarbon and sulfur poison resistant than Cu-ZSM-5 with medium-pore.展开更多
This article describes the use of a boron-doped diamond electrode (BDDE) as an electrochemical sensor for the simultaneous determination of omnipaque (OMP) and paracetamol (PCM) in perchloric acid medium (HClO4 0.1 M)...This article describes the use of a boron-doped diamond electrode (BDDE) as an electrochemical sensor for the simultaneous determination of omnipaque (OMP) and paracetamol (PCM) in perchloric acid medium (HClO4 0.1 M) and in complex matrices such as tomato, carrot and cucumber juices and waste water from the Treichville University Hospital. Voltammetric studies allowed us to have well-defined oxidation peaks at distinct potentials of OMP (E = 0.5 V/SCE) and PCM (E = 0.7 V/SCE). Under optimized conditions, well-defined quantities of OMP and PCM, introduced simultaneously by metered additions, gave linear responses in concentration ranges of 259.8 - 467.2 μM for OMP and 58.73 - 116.3 μM PCM. The detection limits obtained are 7.23 μΜ and 3.6 μΜ respectively for OMP and PCM with recovery rates between 85.8% ± 0.1% and 92.6% ± 0.1% for OMP and between 99.9% ± 0.1% and 101.2% ± 0.4% for the PCM. This technique has been successfully used to simultaneously detect these pharmaceuticals in these complex environments. It allows recovery of OMP and PCM respectively up to 97.5% ± 0.0% and 91.6% ± 0.3% in tomato juice;100.0% ± 0.0% and 95.2% ± 0.2% in carrot juice;101.4% ± 0.1% and 97.3% ± 0.3% in cucumber juice;100.1% ± 0.9% and 100.9% ± 0.1% in wastewater. The relevance of this technique for the simultaneous detection of OMP and PCM in tomato, carrot, cucumber juices and in waste water can be studied in the context of the contamination of certain fruits and vegetables by the substances organic pharmaceuticals released into the environment without prior treatment.展开更多
An electroanalytical method was developed for the direct quantitative determination of paracetamol in tablets based on its oxidation behavior. The electrochemical oxidation and determination of paracetamol were easily...An electroanalytical method was developed for the direct quantitative determination of paracetamol in tablets based on its oxidation behavior. The electrochemical oxidation and determination of paracetamol were easily carried out on born-doped diamond (BDD) electrode using two voltammetric techniques (CV and DPV). The electrochemical measurements performed by cyclic voltammetric (CV) and differential pulse voltammetry (DPV) techniques were carried out using a cathodically pretreated boron-doped diamond electrode in HClO4 and KClO4 electrolytes. HClO4 was then selected for analytical purposes and scan rate studies were also completed. The oxidation of the paracetamol is found to be irreversible and a diffusion-controlled nature of the paracetamol oxidation peak was established. A linear calibration curve for DPV analysis was constructed in the paracetamol concentration range from 0 μM to 13.87 μM, with 0.16 μM and 0.55 μM as the detection and quantification limit respectively.展开更多
文摘This study was aimed to investigate the effects of hydrothermal aging, propene and SO<sub>2</sub> poisoning on the ammonia-selective catalytic reduction (NH<sub>3</sub>-SCR) performance of both Cu-SAPO-34 and Cu-ZSM-5. The catalytic activities of fresh, aged and poisoned samples were tested in ammonia-selective catalytic reduction (NH<sub>3</sub>-SCR) of NO<sub>x</sub> conditions. The XRD, TG and N<sub>2</sub>-desorption results showed that the structures of the Cu-SAPO-34 and Cu-ZSM-5 remained intact after 750˚C hydrothermally aged, SO<sub>2</sub> and propene poisoned. After hydrothermal aging at 750˚C for 12 h, the NO reduction performance of Cu-ZSM-5 was significantly reduced at lower temperatures, while that of Cu-SAPO-34 was less affected. Moreover, Cu-SAPO-34 catalyst showed high NO conversion with SO<sub>2</sub> or propene compared to Cu-ZSM-5. However, Cu-ZSM-5 showed a larger drop in catalytic activity with SO<sub>2</sub> or propene compared to Cu-SAPO-34 catalyst. The H<sub>2</sub>-TPR results showed that Cu<sup>2 </sup> ions could be reduced to Cu<sup> </sup> and Cu<sup>0</sup> for Cu-ZSM-5, while no significant transformation of copper species was observed for Cu-SAPO-34. Meanwhile, the UV-vis DRS results showed that CuO species were formed in Cu-ZSM-5, while little changes were observed for the Cu-SAPO-34. Cu-SAPO-34 showed high sulfur and hydrocarbon poison resistance compared to Cu-ZSM-5. In summary, Cu-SAPO-34 with small-pore zeolite showed higher hydrothermal stability and better hydrocarbon and sulfur poison resistant than Cu-ZSM-5 with medium-pore.
文摘This article describes the use of a boron-doped diamond electrode (BDDE) as an electrochemical sensor for the simultaneous determination of omnipaque (OMP) and paracetamol (PCM) in perchloric acid medium (HClO4 0.1 M) and in complex matrices such as tomato, carrot and cucumber juices and waste water from the Treichville University Hospital. Voltammetric studies allowed us to have well-defined oxidation peaks at distinct potentials of OMP (E = 0.5 V/SCE) and PCM (E = 0.7 V/SCE). Under optimized conditions, well-defined quantities of OMP and PCM, introduced simultaneously by metered additions, gave linear responses in concentration ranges of 259.8 - 467.2 μM for OMP and 58.73 - 116.3 μM PCM. The detection limits obtained are 7.23 μΜ and 3.6 μΜ respectively for OMP and PCM with recovery rates between 85.8% ± 0.1% and 92.6% ± 0.1% for OMP and between 99.9% ± 0.1% and 101.2% ± 0.4% for the PCM. This technique has been successfully used to simultaneously detect these pharmaceuticals in these complex environments. It allows recovery of OMP and PCM respectively up to 97.5% ± 0.0% and 91.6% ± 0.3% in tomato juice;100.0% ± 0.0% and 95.2% ± 0.2% in carrot juice;101.4% ± 0.1% and 97.3% ± 0.3% in cucumber juice;100.1% ± 0.9% and 100.9% ± 0.1% in wastewater. The relevance of this technique for the simultaneous detection of OMP and PCM in tomato, carrot, cucumber juices and in waste water can be studied in the context of the contamination of certain fruits and vegetables by the substances organic pharmaceuticals released into the environment without prior treatment.
文摘An electroanalytical method was developed for the direct quantitative determination of paracetamol in tablets based on its oxidation behavior. The electrochemical oxidation and determination of paracetamol were easily carried out on born-doped diamond (BDD) electrode using two voltammetric techniques (CV and DPV). The electrochemical measurements performed by cyclic voltammetric (CV) and differential pulse voltammetry (DPV) techniques were carried out using a cathodically pretreated boron-doped diamond electrode in HClO4 and KClO4 electrolytes. HClO4 was then selected for analytical purposes and scan rate studies were also completed. The oxidation of the paracetamol is found to be irreversible and a diffusion-controlled nature of the paracetamol oxidation peak was established. A linear calibration curve for DPV analysis was constructed in the paracetamol concentration range from 0 μM to 13.87 μM, with 0.16 μM and 0.55 μM as the detection and quantification limit respectively.