期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Contribution to Asymmetrical Compensation through Parallel Controllers of FACTS (STATCOM)—IPC 240 Dual for a Power Transmission Line
1
作者 Kengne Chatue Charlène Steva Mengata Mengounou Ghislain +2 位作者 koko koko joseph Batassou Guilzia Jeannot Nneme Nneme Leandre 《World Journal of Engineering and Technology》 2023年第1期20-40,共20页
This work is part of the resolution of problems encountered on a 225 KV MANGOMBE-OYOMABANG line. This line is characterized by important technical losses, so that the voltage injected in the busbar is always lower tha... This work is part of the resolution of problems encountered on a 225 KV MANGOMBE-OYOMABANG line. This line is characterized by important technical losses, so that the voltage injected in the busbar is always lower than 200kV. The main objective of this work is to show the new solutions that can provide a combined FACTS-STATCOM and IPC 240 dual system on this line. Then to show the limitation of STATCOM compared to RPI 240. The results obtained allowed us to observe that in symmetrical operation the STATCOM improves the voltage profile on the busbar and in asymmetrical operation we found that it continues to regulate the voltage of each phase despite the unbalance. But the system remains too unbalanced because of the sequence current flow. The IPC 240 corrects this limitation, allowing asymmetrical operation of the line in an emergency while providing continuous service to the load. 展开更多
关键词 FACTS STATCOM IPC 240 Dual SYMMETRY Asymmetry CONTINGENCY Voltage Profile
下载PDF
Contribution to the Optimization of the Transient Stability of an Electric Power Transmission Network Using a Universal Power Flow Compensator Controlled by a Three-Stage Inverter 被引量:2
2
作者 koko koko joseph Nneme Nneme Léandre Ndjakomo Essiane Salomé 《World Journal of Engineering and Technology》 2020年第4期675-688,共14页
The use of an electrical network as close as possible to its limits can lead to its instability in the event of a high amplitude disturbance. The damping of system oscillations can be achieved by conventional means of... The use of an electrical network as close as possible to its limits can lead to its instability in the event of a high amplitude disturbance. The damping of system oscillations can be achieved by conventional means of voltage and speed regulation but also by FACTS (Flexible AC Transmission Systems) devices, which are increasingly used in power networks. In this work, optimal control coordination between a hybrid power flow controller and a three-level inverter was used to improve the transient stability of a transmission line. The UPFC is a combination of a serial compensator (SSSC) and a parallel compensator (STATCOM) both connected to a DC-LINK DC bus. The SSSC acts as a voltage source for the network and injects a voltage that can be adjusted in phase and amplitude in addition to the network voltage;the STATCOM acts as a current source. The approach used is tested in the Matlab Simulink environment on a single machine network. Optimal controller tuning gives a better transient stability improvement by reducing the transport angle oscillations from 248.17% to 9.85%. 展开更多
关键词 FACTS UPFC Three-Stage Inverter PI Power Transit Transient Stability
下载PDF
Comparative Analysis of Hybrid Controllers of Done Systems (UPFC) and Interphase Power Regulators Type RPI 30p15 on Contingency Management in Electrical Networks
3
作者 koko koko joseph Nneme Nneme Léandre +1 位作者 Ndjakomo Essiane Salomé Batassou Guilzia Jeannot 《World Journal of Engineering and Technology》 2021年第3期708-726,共19页
The aim of this work is to demonstrate that interphase power regulators (I</span></span><span style="white-space:normal;"><span style="font-family:"">PR) bring new... The aim of this work is to demonstrate that interphase power regulators (I</span></span><span style="white-space:normal;"><span style="font-family:"">PR) bring new and interesting ultra-solutions that complement those already taken into account by the FACTS (Flexible Alternative Transmission System) in the resolution of the problems related to the power flow in the AC transmission networks. In order to facilitate the understanding of this work, a comparative study of the performances of the two technologies between the UPFC (Unified Power Flow Controller) and RPI was carried out and at the end of which we were able to highlight the preponderance of RPI compared to the UPFC in the bypassing of the short-circuit fault insofar as the latter allows, in particular, an increase in the transformation capacity without an increase in the level of the short-circuit. The decoupled watt-var method has been used to control the UPFC while the RPI is controlled by phase shift. The simulation results are obtained in the Matlab Simulink environment and show the flexibility of the RPI compared to the UPFC in limiting strong contingencies. 展开更多
关键词 Transmission Line High Contingency FACTS PST TCPST UPFC Three-Leg RPI 30P15 Phase-Shifting Transformer Modeling
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部