期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Determination of Element Levels of Lagoon from Townships near Cocody City Abidjan Côte D’Ivoire Using Energy Dispersive X-Ray Fluorescence 被引量:1
1
作者 Alfred Djoman Djama Agbo koudou djagouri +1 位作者 Jean-Claude Olkalé Brigui Konin Pierre-Claver Kakou 《World Journal of Nuclear Science and Technology》 2021年第2期109-118,共10页
Eight water bottles from Ebrie lagoon with pollution potency were studied using nuclear chemistry technique and Energy dispersive X-ray fluorescence. This pollution is characterized by pH and conductivity parameters, ... Eight water bottles from Ebrie lagoon with pollution potency were studied using nuclear chemistry technique and Energy dispersive X-ray fluorescence. This pollution is characterized by pH and conductivity parameters, concentrations average in mg/L of metals such Fe (0.731), Mn (0.345), Cr (0.070), Cu (0.014) and concentrations of nutrients known to be pollutants and toxic for living or-ganisms. These heavy metals are dangerous to the lives, the local inhabitants and also a threat to aquatic life since this water is essential for the economical town, Abidjan. According to the Manganese concentration average (0.345 mg) values that higher than WHO (0.05 mg) value, the main likely source of pollu-tants is anthropogenic, industrial and agricultural. This study also shows the use of materials and lubricants near the lagoon that pollute this water. 展开更多
关键词 Ebrie Lagoon POLLUTION Heavy Metals Energy Dispersive X-Ray Fluorescence
下载PDF
Bulk Etch Rate of LR 115 Polymeric Radon Detector
2
作者 Dabo S. I. Agba koudou djagouri +1 位作者 Bogbe D. L. H. Gogon Aka A. Koua 《Detection》 2021年第1期1-8,共8页
In this study, we used strippable LR 115 type 2 which is a Solid State Nuclear Track Detector (SSNTD) widely known for radon gas detection and measurement. The removed thickness of the active layer of samples of this ... In this study, we used strippable LR 115 type 2 which is a Solid State Nuclear Track Detector (SSNTD) widely known for radon gas detection and measurement. The removed thickness of the active layer of samples of this SSNTD, were determined by measuring the average initial thickness (before etching) and residual thickness after 80 to 135 minutes chemical etching in the standard conditions, using an electronic comparator. These results allowed the calculation of the bulk etch rate of this detector in a simple way. The mean value obtained is (3.21 ± 0.21) μm/h. This value is in close agreement with those reported by different authors. It is an important parameter for alpha track counting on the sensitive surface of this polymeric detector after chemical etching because track density depends extremely on its removed layer. This SSNTD was then used for environmental radon gas monitoring in C&#244;te d’Ivoire. 展开更多
关键词 Strippable LR 115 Type 2 Chemical Etching Removed Layer Bulk Etch Rate
下载PDF
Assessment of Radioactivity in Borehole Waters of the North Riviera Sodeci Catchment Field in Abidjan, Côte d’Ivoire
3
作者 Epi Zita Tatiana Kocola Achi Bogbé Douo Louis Huberson Gogon +1 位作者 koudou djagouri Marie Chantal Kouassi Goffri 《World Journal of Nuclear Science and Technology》 2022年第1期55-68,共14页
The radioactive isotopes of the decay series of uranium-238 (<sup>238</sup>U), thorium-232 (<sup>232</sup>Th) and potassium-40 (<sup>40</sup>K) occur naturally in varying amounts in... The radioactive isotopes of the decay series of uranium-238 (<sup>238</sup>U), thorium-232 (<sup>232</sup>Th) and potassium-40 (<sup>40</sup>K) occur naturally in varying amounts in groundwater. They are the subject of many measures, mainly because of the risk they represent from a public health point of view. The purpose of this study is to measure the radioisotope content of borehole waters from the north riviera (NR) catchment field of the Ivorian drinking water distribution company (SODECI). These measurements will make it possible to assess the absolute levels of radioisotopes in the water from SODECI’s boreholes used directly for drinking or swimming, and possibly the associated risk from a public health point of view. To achieve this, a sampling campaign from the seven functional boreholes and the control or treatment tower took place in July 2018 at the NR well field. The analysis of radionuclides by gamma spectrometry was carried out in the laboratory of the Radiation Protection Institute (RPI) of the Ghana Atomic Energy Commission (GAEC). The naturally occurring radionuclides identified during the borehole water samples analysis are <sup>238</sup>U, <sup>232</sup>Th, and <sup>40</sup>K. The results reveal that the specific activities of uranium vary from 0.45 ± 0.18 Bq/L to 0.55 ± 0.17 Bq/L with an average of 0.49 ± 0.15 Bq/L. Those of thorium vary from 0.66 ± 0.14 Bq/L to 0.78 ± 0.18 Bq/L with an average of 0.72 ± 0.16 Bq/L and potassium of 4.14 ± 0.53 Bq/L at 5.87 ± 0.60 Bq/L with an average of 5.32 ± 0.58 Bq/L. 展开更多
关键词 North Rivera (NR) Catchment Field Drilling Water Natural Radionuclides Uranium THORIUM Potassium
下载PDF
Measurement of Natural Radioactivity in Lagoon Sands Used in Construction in the District of Abidjan, Côte d’Ivoire
4
作者 Olkalé Jean-Claude Brigui Tekpo Paul Amewe Dali +4 位作者 koudou djagouri Bogbé Douo Louis Huberson Gogon Samafou Penabei Aka Antonin Koua Georges Alain Monnehan 《World Journal of Nuclear Science and Technology》 2022年第1期43-54,共12页
Sand is an important natural material for the construction of houses, work buildings and other public spaces. This work, which is one of the first contributions to the environmental quality of construction materials, ... Sand is an important natural material for the construction of houses, work buildings and other public spaces. This work, which is one of the first contributions to the environmental quality of construction materials, concerns the measurement of natural radioactivity in the lagoon sands collected in the district of Abidjan. Nineteen (19) samples of these sands are analyzed by gamma-ray spectrometry equipped with HPGe detector. The mean values obtained for <sup>226</sup>Ra, <sup>232</sup>Th and <sup>40</sup>K are respectively 7.76 ± 1.84 Bq·kg<sup>-1</sup>, 5.21 ± 1.36 Bq·kg<sup>-1</sup>, and 217.31 ± 5.03 Bq·kg<sup>-1</sup>. The estimated average value of radium equivalent (Raeq) is 31.94 Bq·kg-1. The results show that the average values obtained are far lower than the global limits of 35, 30, and 400 Bq·kg<sup>-1</sup> for the concentrations of <sup>226</sup>Ra, <sup>232</sup>Th and <sup>40</sup>K, respectively, and 370 Bq·kg<sup>-1 </sup>for the equivalent radium established by the United Nations Scienti<span style="white-space:nowrap;">&#64257;</span>c Committee on the Effects of Atomic Radiation (UNSCEAR). Therefore, the use of the analyzed lagoon sand samples in the different construction sectors should not cause serious radiological effects on the populations living in the District of Abidjan. Our results provide new data on building materials radioactivity in C<span style="white-space:nowrap;">&#244;</span>te d’Ivoire and all over the World. They can also be used as a reference for future work. 展开更多
关键词 Radionuclide Concentration Gamma-Ray Spectrometry Radium Equivalent Activity Lagoon Sand ABIDJAN
下载PDF
Diagnostic Reference Level in Frontal Chest X-Ray in Western Côte d’Ivoire 被引量:2
5
作者 Issa Konate George A. Monnehan +3 位作者 Douo B. L. H. Gogon Tekpo P. A. Dali Aka A. Koua koudou djagouri 《World Journal of Nuclear Science and Technology》 2019年第4期147-158,共12页
Our study aims to determine diagnostic reference levels (DRL) for chest front examination in postero anterior (PA) for optimizing patient entrance surface dose (ESD) and dose-area product (DAP) of patients in west of ... Our study aims to determine diagnostic reference levels (DRL) for chest front examination in postero anterior (PA) for optimizing patient entrance surface dose (ESD) and dose-area product (DAP) of patients in west of C&ocirc;te d’Ivoire. 90 patients from three hospitals undergoing conventional radiology were considered. The ESD and DAP for each patient were obtained during chest radiography (PA) examination. The measurements were performed with the device call Dose-Area Product-meter (DAP-meter) with brand Diamentor M4-KDK, type 11017. The DRL were obtained in applying the 75th percentile statistical method to the obtained ESD and DAP. The obtained DRL in ESD for chest radiography for all rooms is 0.40 mGy and in DAP is 54.85 cGy&middot;cm2. Our DRL for ESD is higher than those obtained in Abidjan District and in other countries like UK and Cameroon. Our DRL for DAP is higher than those from Abidjan and all other countries for which a similar study was made. The comparison of these values to those from Abidjan and other countries, shows us that radiology technicians can make efforts to choose radiological parameters to reduce ESD. They must use convenable the X-rays tube to reduce DAP by reducing the patient exposure surface. 展开更多
关键词 Conventional RADIOLOGY ENTRANCE Surface-Dose Dose-Area-Product Dose-Area Product-Meter DIAGNOSTIC REFERENCE Levels
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部