期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Benchmark experiment on slab^(238)U with D-T neutrons for validation of evaluated nuclear data 被引量:1
1
作者 Yan-Yan Ding Yang-Bo Nie +9 位作者 Yue Zhang Zhi-Jie Hu Qi Zhao Huan-Yu Zhang kuo-zhi xu Shi-Yu Zhang Xin-Yi Pan Chang-Lin Lan Jie Ren Xi-Chao Ruan 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第2期145-159,共15页
A benchmark experiment on^(238)U slab samples was conducted using a deuterium-tritium neutron source at the China Institute of Atomic Energy.The leakage neutron spectra within energy levels of 0.8-16 MeV at 60°an... A benchmark experiment on^(238)U slab samples was conducted using a deuterium-tritium neutron source at the China Institute of Atomic Energy.The leakage neutron spectra within energy levels of 0.8-16 MeV at 60°and 120°were measured using the time-of-flight method.The samples were prepared as rectangular slabs with a 30 cm square base and thicknesses of 3,6,and 9 cm.The leakage neutron spectra were also calculated using the MCNP-4C program based on the latest evaluated files of^(238)U evaluated neutron data from CENDL-3.2,ENDF/B-Ⅷ.0,JENDL-5.0,and JEFF-3.3.Based on the comparison,the deficiencies and improvements in^(238)U evaluated nuclear data were analyzed.The results showed the following.(1)The calculated results for CENDL-3.2 significantly overestimated the measurements in the energy interval of elastic scattering at 60°and 120°.(2)The calculated results of CENDL-3.2 overestimated the measurements in the energy interval of inelastic scattering at 120°.(3)The calculated results for CENDL-3.2 significantly overestimated the measurements in the 3-8.5 MeV energy interval at 60°and 120°.(4)The calculated results with JENDL-5.0 were generally consistent with the measurement results. 展开更多
关键词 Leakage neutron spectra URANIUM D-T neutron source Evaluated nuclear data
下载PDF
In-beam gamma rays of CSNS Back-n characterized by black resonance filter
2
作者 Jin-Cheng Wang Jie Ren +68 位作者 Wei Jiang Xi-Chao Ruan Ying-Yi Liu Hao-Lan Yang kuo-zhi xu Xin-Yi Pan Qi Sun Jie Bao Han-Xiong Huang Hao-Fan Bai Jiang-Bo Bai Ping Cao Qi-Ping Chen Yong-Hao Chen Wen-Hao Duan An-Chuan Fan Rui-Rui Fan Chang-Qing Feng Min-Hao Gu Chang-Cai Han Zi-Jie Han Guo-Zhu He Yong-Cheng He Yang Hong Yi-Wei Hu Zhi-Jie Jiang Ling Kang Chang-Lin Lan Bo Li Feng Li Qiang Li Xiao Li Yang Li Jie Liu Rong Liu Shu-Bin Liu Yi-Na Liu Guang-Yuan Luan Chang-Jun Ning Yi-Jia Qiu Wen-Kai Ren Zhi-Zhou Ren Zhao-Hui Song Kang Sun Zhi-Xin Tan Jing-Yu Tang Sheng-Da Tang Li-Jiao Wang Peng-Cheng Wang Zhao-Hui Wang Zhong-Wei Wen Xiao-Guang Wu xuan Wu Ze-Peng Wu Cong Xia Li-Kun Xie Han Yi Tao Yu Yong-Ji Yu Guo-Hui Zhang Hang-Chang Zhang Qi-Wei Zhang Xian-Peng Zhang Yu-Liang Zhang Zhi-Yong Zhang Mao-Yuan Zhao Zhi-Hao Zhou Ke-Jun Zhu Chong Zou 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第10期149-160,共12页
The back-streaming white-neutron beamline(Back-n)of the China Spallation Neutron Source is an essential neutronresearch platform built for the study of nuclear data,neutron physics,and neutron applications.Many types ... The back-streaming white-neutron beamline(Back-n)of the China Spallation Neutron Source is an essential neutronresearch platform built for the study of nuclear data,neutron physics,and neutron applications.Many types of cross-sectional neutron-reaction measurements have been performed at Back-n since early 2018.These measurements have shown that a significant number of gamma rays can be transmitted to the experimental stations of Back-n along with the neutron beam.These gamma rays,commonly referred to as in-beam gamma rays,can induce a non-negligible experimental background in neutron-reaction measurements.Studying the characteristics of in-beam gamma rays is important for understanding the experimental background.However,measuring in-beam gamma rays is challenging because most gamma-ray detectors are sensitive to neutrons;thus,discriminating between neutron-induced signals and those from in-beam gamma rays is difficult.In this study,we propose the use of the black resonance filter method and a CeBr_(3) scintillation detector to measure the characteristics of the in-beam gamma rays of Back-n.Four types of black resonance filters,^(181)Ta,^(59)Co,^(nat)Ag,and^(nat)Cd,were used in this measurement.The time-of-flight(TOF)technique was used to select the detector signals remaining in the absorption region of the TOF spectra,which were mainly induced by in-beam gamma rays.The energy distribution and flux of the in-beam gamma rays of Back-n were determined by analyzing the deposited energy spectra of the CeBr_(3) scintillation detector and using Monte Carlo simulations.Based on the results of this study,the background contributions from in-beam gamma rays in neutron-reaction measurements at Back-n can be reasonably evaluated,which is beneficial for enhancing both the experimental methodology and data analysis. 展开更多
关键词 In-beam gamma rays Back-n CeBr_(3)scintillator Black filter resonance technique
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部