The transfer of pressurized water reactor(PWR)technology from France to China is an important event in the history of Sino-French scientific and technological relations.China has gradually achieved self-reliance in th...The transfer of pressurized water reactor(PWR)technology from France to China is an important event in the history of Sino-French scientific and technological relations.China has gradually achieved self-reliance in the field of PWR technology through the introduction and subsequent absorption of France's 900 MW reactors.Compared with the process of introducing and absorbing similar technology from the United States by France,China's experience has been more complicated.This circumstance reflects the differences in the nuclear power technology systems between the two countries.France's industrial strength and early acquisition of nuclear power technology laid a solid foundation for mastering PWR technology.On the other hand,although China established a weak foundation through the implementation of the"728 Project,"and tried hard to negotiate with France,the substantive content of the technology transfer was very limited.By way of the policy transition from"unhooking of technology and trade"to"integration of technology and trade,"China ultimately accomplished the absorption and innovation of PWR technology through the Ling'ao NPP.展开更多
After World War II,the choice of the plutonium bomb as the technology roadmap for the first French atomic bomb was not a military issue,but rather one guided by civilian nuclear technology policy.After consideration o...After World War II,the choice of the plutonium bomb as the technology roadmap for the first French atomic bomb was not a military issue,but rather one guided by civilian nuclear technology policy.After consideration of the amount of uranium to be mined,technical reserves,and the financial situation,the civilian nuclear energy project of the Commissariatàl’énergie Atomique(CEA)was based on plutonium and natural uranium as the fissile materials,which indirectly provided enough plutonium for the future development of a nuclear weapon.When the Fourth Republic decided to develop the atomic bomb,a“Common Core”was established with the CEA,a public institution,as the lead,assisted by the military.Faced by the US embargo of nuclear weapons technology,the co-existence of civilian and military branches and their collaboration to some degree in the CEA not only made it a civilian-military complex,but also facilitated breakthroughs in the core technologies of implosion,the plutonium core,the tamper,and the neutron source.The success of the first French nuclear weapons test on February 13,1960,announced that France was on its way to becoming self-reliant in the military use of nuclear science.展开更多
Objective The dialysate membrane can be classified into acetate membrane and synthetic membrane,while the latter can be further divided into polysulfone,polyacrylonitrile,etc.Polyethersulfone membrane is high molecula...Objective The dialysate membrane can be classified into acetate membrane and synthetic membrane,while the latter can be further divided into polysulfone,polyacrylonitrile,etc.Polyethersulfone membrane is high molecular membrane material with excellent biocompatibility,stable mechanical properties,high temperature and pressure resistance,and good cleaning performance,which has been applied for more than 10 years.This trial is to assess the safety and efficacy of hollow polysulfone membrane fiber dialyzer with pattern number Enttex^(TM)-16LF(E60)for hemodialysis in patients with acute or chronic renal failure due to multiple factors.Methods Totally 76 patients receiving maintenance hemodialysis were included in a two-site,random,open label,two-stage,positive crossover and non inferiority validation study.The clinical efficacy and safety of the test device were observed,which was a hollow fiber dialyzer produced by Guangzhou Enttex Medical Products Co.,Ltd.,with polyethersulfone membrane imported from Germany.It was a low flux dialyzer with the pattern number of EnttexTM-16LF(E60).Inclusion criteria:①patients with acute or chronic renal failure due to various reasons who needed hemodialysis;②18 to 80 years old,gender unlimited;③patients who received stable dialysis for more than 3 months,regular hemodialysis 3 times a week,4 h at each time,blood flow rate of 200~350ml/min;④using bicarbonate dialysate at a flow rate of 500ml/min;⑤patients with arteriovenous fistula or who received artificial blood vessel puncture dialysis;received anticoagulation by heparin or low molecular weight heparin.Exclusion criteria:①patients needing heparin free dialysis for severe anemia,tumor and active bleeding;②patients with severe cardiac(gradeⅢcardiac function),hepatic(severe hepatitis and cirrhosis)and pulmonary diseases(severe respiratory failure).Results Comparison of parameters,including the changes of Kt/V,general creatinine and urea clearance rates and URR(urea reduction rate)shows no statistical significance in differences between the two devices,indicating that the test and control devices can equally and effectively eliminate toxins including creatinine and urea,etc.PPP and MITTP results are consistent.Comparison of ultrafiltration rates between two groups of patients shows no statistical difference.PPP and MITTP results are consistent,indicating that both the test device and control device can effectively eliminate water.In MITTP,electrolytes including K^+,Na^+,Cl^-,Ca^2+,HCO3^-,etc.show no statistical significance in difference between the test and control devices before and after dialysis(P>0.05).After treating by using test and control devices,body weight,serum potassium and phos-phorus all significantly decrease(P<0.001);serum Ca^2+,PO2,PCO2and HCO3^-all significantly increase(P<0.001).These results indicate that both the test and control devices can effectively eliminate serum potassium and phosphorus,and eliminate excess water in body,maintain the balance between liquid and electrolytes in patients.PPP and MITTP results are consistent.Conclusion This clinical trial confirms that hollow polyethersulfone membrane fiber dialyzer can be safely and effectively used in hemodialysis therapy.展开更多
基金a phase study of a key project of the Fourteenth Five-Year Plan of the Institute for the History of Natural Sciences,Chinese Academy of Sciences:“A Comparative Study of the Sino-Foreign History of Scientific and Technological Innovation:The Road to Scientific and Technological Self-Reliance and Self-Improvement”,E2291J01。
文摘The transfer of pressurized water reactor(PWR)technology from France to China is an important event in the history of Sino-French scientific and technological relations.China has gradually achieved self-reliance in the field of PWR technology through the introduction and subsequent absorption of France's 900 MW reactors.Compared with the process of introducing and absorbing similar technology from the United States by France,China's experience has been more complicated.This circumstance reflects the differences in the nuclear power technology systems between the two countries.France's industrial strength and early acquisition of nuclear power technology laid a solid foundation for mastering PWR technology.On the other hand,although China established a weak foundation through the implementation of the"728 Project,"and tried hard to negotiate with France,the substantive content of the technology transfer was very limited.By way of the policy transition from"unhooking of technology and trade"to"integration of technology and trade,"China ultimately accomplished the absorption and innovation of PWR technology through the Ling'ao NPP.
基金a phase study of a key project of the Fourteenth Five-Year Plan of the Institute for the History of Natural Sciences,Chinese Academy of Sciences:“A Comparative Study of the Sino-Foreign History of Scientific and Technological Innovation:The Road to Scientific and Technological Self-Reliance and Self-Improvement”(中外科技创新史比较研究——科技自立自强之路)(E2291J01)
文摘After World War II,the choice of the plutonium bomb as the technology roadmap for the first French atomic bomb was not a military issue,but rather one guided by civilian nuclear technology policy.After consideration of the amount of uranium to be mined,technical reserves,and the financial situation,the civilian nuclear energy project of the Commissariatàl’énergie Atomique(CEA)was based on plutonium and natural uranium as the fissile materials,which indirectly provided enough plutonium for the future development of a nuclear weapon.When the Fourth Republic decided to develop the atomic bomb,a“Common Core”was established with the CEA,a public institution,as the lead,assisted by the military.Faced by the US embargo of nuclear weapons technology,the co-existence of civilian and military branches and their collaboration to some degree in the CEA not only made it a civilian-military complex,but also facilitated breakthroughs in the core technologies of implosion,the plutonium core,the tamper,and the neutron source.The success of the first French nuclear weapons test on February 13,1960,announced that France was on its way to becoming self-reliant in the military use of nuclear science.
基金Guangdong Provincial Science and Technology Department Fund Project(507204531040)Guangdong Provincial Science and Technology Plan Fund Project(2013b9040004)
文摘Objective The dialysate membrane can be classified into acetate membrane and synthetic membrane,while the latter can be further divided into polysulfone,polyacrylonitrile,etc.Polyethersulfone membrane is high molecular membrane material with excellent biocompatibility,stable mechanical properties,high temperature and pressure resistance,and good cleaning performance,which has been applied for more than 10 years.This trial is to assess the safety and efficacy of hollow polysulfone membrane fiber dialyzer with pattern number Enttex^(TM)-16LF(E60)for hemodialysis in patients with acute or chronic renal failure due to multiple factors.Methods Totally 76 patients receiving maintenance hemodialysis were included in a two-site,random,open label,two-stage,positive crossover and non inferiority validation study.The clinical efficacy and safety of the test device were observed,which was a hollow fiber dialyzer produced by Guangzhou Enttex Medical Products Co.,Ltd.,with polyethersulfone membrane imported from Germany.It was a low flux dialyzer with the pattern number of EnttexTM-16LF(E60).Inclusion criteria:①patients with acute or chronic renal failure due to various reasons who needed hemodialysis;②18 to 80 years old,gender unlimited;③patients who received stable dialysis for more than 3 months,regular hemodialysis 3 times a week,4 h at each time,blood flow rate of 200~350ml/min;④using bicarbonate dialysate at a flow rate of 500ml/min;⑤patients with arteriovenous fistula or who received artificial blood vessel puncture dialysis;received anticoagulation by heparin or low molecular weight heparin.Exclusion criteria:①patients needing heparin free dialysis for severe anemia,tumor and active bleeding;②patients with severe cardiac(gradeⅢcardiac function),hepatic(severe hepatitis and cirrhosis)and pulmonary diseases(severe respiratory failure).Results Comparison of parameters,including the changes of Kt/V,general creatinine and urea clearance rates and URR(urea reduction rate)shows no statistical significance in differences between the two devices,indicating that the test and control devices can equally and effectively eliminate toxins including creatinine and urea,etc.PPP and MITTP results are consistent.Comparison of ultrafiltration rates between two groups of patients shows no statistical difference.PPP and MITTP results are consistent,indicating that both the test device and control device can effectively eliminate water.In MITTP,electrolytes including K^+,Na^+,Cl^-,Ca^2+,HCO3^-,etc.show no statistical significance in difference between the test and control devices before and after dialysis(P>0.05).After treating by using test and control devices,body weight,serum potassium and phos-phorus all significantly decrease(P<0.001);serum Ca^2+,PO2,PCO2and HCO3^-all significantly increase(P<0.001).These results indicate that both the test and control devices can effectively eliminate serum potassium and phosphorus,and eliminate excess water in body,maintain the balance between liquid and electrolytes in patients.PPP and MITTP results are consistent.Conclusion This clinical trial confirms that hollow polyethersulfone membrane fiber dialyzer can be safely and effectively used in hemodialysis therapy.