Onlineγ-spectrometry systems for inland waters,most of which extract samples in situ and in real time,are able to produce reliable activity concentration measurements for waterborne radionuclides only when they are d...Onlineγ-spectrometry systems for inland waters,most of which extract samples in situ and in real time,are able to produce reliable activity concentration measurements for waterborne radionuclides only when they are distributed relatively uniformly and enter into a steady-state diffusion regime in the measurement chamber.To protect residents’health and ensure the safety of the living environment,better timeliness is required for this measurement method.To address this issue,this study established a mathematical model of the online waterγ-spectrometry system so that rapid warning and activity estimates can be obtained for water under non-steady-state(NSS)conditions.In addition,the detection efficiency of the detector for radionuclides during the NSS diffusion process was determined by applying the computational fluid dynamics technique in conjunction with Monte Carlo simulations.On this basis,a method was developed that allowed the online waterγ-spectrometry system to provide rapid warning and activity concentration estimates for radionuclides in water.Subsequent analysis of the NSS-mode measurements of^(40)K radioactive solutions with different activity concentrations determined the optimum warning threshold and measurement time for producing accurate activity concentration estimates for radionuclides.The experimental results show that the proposed NSS measurement method is able to give warning and yield accurate activity concentration estimates for radionuclides 55.42 and 69.42 min after the entry of a 10 Bq/L^(40)K radioactive solution into the measurement chamber,respectively.These times are much shorter than the 90 min required by the conventional measurement method.Furthermore,the NSS measurement method allows the measurement system to give rapid(within approximately 15 min)warning when the activity concentrations of some radionuclides reach their respective limits stipulated in the Guidelines for Drinking-water Quality of the WHO,suggesting that this method considerably enhances the warning capacity of in situ online waterγ-spectrometry systems.展开更多
This paper describes a low-cost and fast method to evaluate gross α and β^(-) radioactivities in natural water based on an online high-purity germanium detector gamma measurement system.The major gamma activities in...This paper describes a low-cost and fast method to evaluate gross α and β^(-) radioactivities in natural water based on an online high-purity germanium detector gamma measurement system.The major gamma activities in natural water are provided by natural and artificial radionuclides such as ^(40) K,^(137)Cs,and radionuclides belonging to ^(238)U and ^(232)Th series.The main a emitters related to gamma emissions in natural water are ^(224)Ra(240.98 keV)and ^(226)Ra(186.21 keV),and the β^(-) emitters are ^(40) K(1460.85 keV),^(214)Bi(609.31 keV),^(208)Tl(583.19 keV),and ^(214)Pb(351.93 keV).The formula for gross α and β^(-) activity concentration is based on these radionuclides,and the short half-life decay products are considered in the calculation.The detection efficiency of the device across energy region(0–3 MeV)is obtained through Monte Carlo simulation,and a calibration experiment is conducted to verify the simulation results.Gamma radioactivity is measured continuously for 114 d in Pixian County and Dongfeng Canal located in the Zouma River,Chengdu,Sichuan Province,China.A comparison of the calculation results and monitoring data from the Sichuan Management and Monitoring Center Station of Radioactive Environment indicates that the percentage and absolute error of a activity concentration is lower than 53%and 0.02 Bq/L,respectively,and that of β-activity concentration is lower than 33.2%and 0.016 Bq/L,respectively.The method can rapidly determine gross α and β^(-) activity concentrations in natural water online.展开更多
Based on the geochemical prospecting data, we have calculated the gamma absorbed dose rates in air 1 m above the ground surface in the Chengdu Plain, analyzed the relationship between the geological conditions and the...Based on the geochemical prospecting data, we have calculated the gamma absorbed dose rates in air 1 m above the ground surface in the Chengdu Plain, analyzed the relationship between the geological conditions and the distribution of the natural radionuclides, and preliminarily studied the influence of the geological conditions on the terrestrial radiation level in the Chengdu Plain. The result shows that the terrestrial radiation level in the Chengdu Plain is slightly lower than the average values of China and varies greatly according to the complex geological conditions.展开更多
To perform an integral simulation of a pool-type reactor using CFD code,a multi-physics coupled code MPC-LBE for an LBE-cooled reactor was proposed by integrating a point kinetics model and a fuel pin heat transfer mo...To perform an integral simulation of a pool-type reactor using CFD code,a multi-physics coupled code MPC-LBE for an LBE-cooled reactor was proposed by integrating a point kinetics model and a fuel pin heat transfer model into self-developed CFD code.For code verification,a code-to-code comparison was employed to validate the CFD code.Furthermore,a typical BT transient benchmark on the LBE-cooled XADS reactor was selected for verification in terms of the integral or system performance.Based on the verification results,it was demonstrated that the MPC-LBE coupled code can perform thermal-hydraulics or safety analyses for analysis for processes involved in LBE-cooled pool-type reactors.展开更多
The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectr...The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectrum evaluation method is able to obtain the background-corrected and interference-free net peaks, which is significant for quantization analyses. A variety of analytical parameters and functions to describe the features of the fluorescence spectra of pure elements are used and established, such as the mass absorption coefficient, the Gi factor, and fundamental fluorescence formulas. The FSLS iterative program was compiled in the C language. The content of each component should reach the convergence criterion at the end of the calculations. After a basic theory analysis and experimental preparation, 13 national standard soil samples were detected using a spectrometer to test the feasibility of using the algorithm. The results show that the calculated contents of Ti, Fe, Ni, Cu, and Zn have the same changing tendency as the corresponding standard content in the 13 reference samples. Accuracies of 0.35% and 14.03% are obtained, respectively, for Fe and Ti, whose standard concentrations are 8.82% and 0.578%, respectively. However, the calculated results of trace elements (only tens of lg/g) deviate from the standard values. This may be because of measurement accuracy and mutual effects between the elements.展开更多
Pulse shaping,which improves signal-to-noise ratio excellently,has been extensively used in nuclear signal processing.This paper presents a cusp-like pulse-shaping technique developed through the recursive difference ...Pulse shaping,which improves signal-to-noise ratio excellently,has been extensively used in nuclear signal processing.This paper presents a cusp-like pulse-shaping technique developed through the recursive difference equation in time domain.It can be implemented in field programmable gate array hardware system.Another flat-topped cusp-like shaper is developed to optimize the time constant of pulse shaping and reduce the influence of ballistic deficit.The methods of both baseline restoration and pile-up rejection are described.The ^(137)Cs energy spectra measured with the digital cusp-like shaper are 6.6% energy resolution,while those by traditional analog pulse shaper are 7.2% energy resolution,under the same conditions.This technique offers flexibility,too,in adjusting the pulse shaper parameters.展开更多
The rapid identification of radioactive substances in public areas is crucial.However,traditional nuclide identification methods only consider information regarding the full energy peaks of the gamma-ray spectrum and ...The rapid identification of radioactive substances in public areas is crucial.However,traditional nuclide identification methods only consider information regarding the full energy peaks of the gamma-ray spectrum and require long recording times,which lead to long response times.In this paper,a novel identification method using the event mode sequence(EMS)information of target radionuclides is proposed.The EMS of a target radionuclide and natural background radiation were established as two different probabilistic models and a decision function based on Bayesian inference and sequential testing was constructed.The proposed detection scheme individually processes each photon.When a photon is detected and accepted,the corresponding posterior probability distribution parameters are estimated using Bayesian inference and the decision function is updated.Then,value of the decision function is compared to preset detection thresholds to obtain a detection result.Experiments on different target radionuclides(137Cs and 60Co)were performed.The count rates of the regions of interest(ROI)in the backgrounds between[651,671],[1154,1186],and[1310,1350]keV were 2.35,5.14,and 0.57 CPS,respectively.The experimental results demonstrate that the average detection time was 6.0 s for 60Co(with an activity of 80400 Bq)at a distance of 60 cm from the detector.The average detection time was 7 s for 137Cs(with an activity of 131000 Bq)at a distance of 90 cm from the detector.The results demonstrate that the proposed method can detect radioactive substances with low activity.展开更多
Currently,the liquid scintillation method is widely used to measure the activity of tritiated water in the primary circuit of nuclear power plants,which leads to the continuous production of radioactive waste during m...Currently,the liquid scintillation method is widely used to measure the activity of tritiated water in the primary circuit of nuclear power plants,which leads to the continuous production of radioactive waste during measurement.In addition,the real-time activity information of tritiated water cannot be obtained.To solve this problem,herein we present an online tritiated water measurement method based on plastic scintillators that used the optical transport process in the Geant 4 software toolkit to build a model of plastic scintillation detection for tritiated water.Through simulation,the basic geometric dimensions of the detector were determined.In this dimension,using one detector to measure for 3 h,when the tritiated water activity was 100 Bq/L,its resolution was 16%(16 Bq/L).In addition,calculations were performed for the presence of other background signals to obtain the minimum detectable concentration.展开更多
Correction to:NUCL SCI TECH(2021)32:143 https://doi.org/10.1007/s41365-021-00982-z In the original article,the funding information were missing and in this correction the funding information is given below:Funding Thi...Correction to:NUCL SCI TECH(2021)32:143 https://doi.org/10.1007/s41365-021-00982-z In the original article,the funding information were missing and in this correction the funding information is given below:Funding This work was supported by the National Natural science Foundation of China(No.41774190),the Special-funded program on national key scientific instruments and equipment development(No.2017YFC0602105),and the Department of Science and Technology of Sichuan Province(No.2020JDRC0109).展开更多
In this study,the theory of minimum detectable activity concentration(MDAC)for airborne gamma-ray spectrometry(AGS)was derived,and the relationship between the MDAC and the intrinsic effi-ciency of a scintillation cou...In this study,the theory of minimum detectable activity concentration(MDAC)for airborne gamma-ray spectrometry(AGS)was derived,and the relationship between the MDAC and the intrinsic effi-ciency of a scintillation counter,volume,and energy res-olution of scintillation crystals,and flight altitude of an aircraft was investigated.To verify this theory,experi-mental devices based on NaI and CeBr 3 scintillation counters were prepared,and the potassium,uranium,and thorium contents in calibration pads obtained via the stripping ratio method and theory were compared.The MDACs of AGS under different conditions were calculated and analyzed using the proposed theory and the Monte Carlo method.The relative errors found via a comparison of the experimental and theoretical results were less than 4%.The theory of MDAC can guide the work of AGS in probing areas with low radioactivity.展开更多
Due to variable time for charge collection,energy resolution of nuclear detectors declines,especially compound semiconductor detectors like cadmium zinc telluride(CdZnTe) detector.To solve this problem,an analog rise-...Due to variable time for charge collection,energy resolution of nuclear detectors declines,especially compound semiconductor detectors like cadmium zinc telluride(CdZnTe) detector.To solve this problem,an analog rise-time discriminator based on charge comparison principle is designed.The reference charge signal after attenuation is compared with the deconvoluted and delayed current signal.It is found that the amplitude of delayed current signal is higher than that of the reference charge signal when rise time of the input signal is shorter than the discrimination time,thus generating gating signal and triggering DMCA(digital multi-channel analyzer) to receive the total integral charge signal.When rise time of the input signal is longer than discrimination time,DMCA remains inactivated and the corresponding total integral charge signal is abandoned.Test results show that combination of the designed rise-time discriminator and DMCA can reduce hole tailing of CdZnTe detector significantly.Energy resolution of the system is 0.98%@662 keV,and it is still excellent under high counting rates.展开更多
基金supported by the National Natural Science Foundation of China(No.42127807)Natural Science Foundation of Sichuan Province of China(Project No.2023NSFSC0008)+1 种基金Uranium Geology Program of China Nuclear Geology(No.202205-6)the Sichuan Science and Technology Program(No.2021JDTD0018)。
文摘Onlineγ-spectrometry systems for inland waters,most of which extract samples in situ and in real time,are able to produce reliable activity concentration measurements for waterborne radionuclides only when they are distributed relatively uniformly and enter into a steady-state diffusion regime in the measurement chamber.To protect residents’health and ensure the safety of the living environment,better timeliness is required for this measurement method.To address this issue,this study established a mathematical model of the online waterγ-spectrometry system so that rapid warning and activity estimates can be obtained for water under non-steady-state(NSS)conditions.In addition,the detection efficiency of the detector for radionuclides during the NSS diffusion process was determined by applying the computational fluid dynamics technique in conjunction with Monte Carlo simulations.On this basis,a method was developed that allowed the online waterγ-spectrometry system to provide rapid warning and activity concentration estimates for radionuclides in water.Subsequent analysis of the NSS-mode measurements of^(40)K radioactive solutions with different activity concentrations determined the optimum warning threshold and measurement time for producing accurate activity concentration estimates for radionuclides.The experimental results show that the proposed NSS measurement method is able to give warning and yield accurate activity concentration estimates for radionuclides 55.42 and 69.42 min after the entry of a 10 Bq/L^(40)K radioactive solution into the measurement chamber,respectively.These times are much shorter than the 90 min required by the conventional measurement method.Furthermore,the NSS measurement method allows the measurement system to give rapid(within approximately 15 min)warning when the activity concentrations of some radionuclides reach their respective limits stipulated in the Guidelines for Drinking-water Quality of the WHO,suggesting that this method considerably enhances the warning capacity of in situ online waterγ-spectrometry systems.
基金the National Science Foundation of China(No.41774147)the National Key R&D Program of China(No.2017YFC0602105)+1 种基金the Science–Technology Support Plan Projects of Sichuan Province(No.2020YJ0334)the Sichuan Science and Technology Program(No.2020JDRC0108).
文摘This paper describes a low-cost and fast method to evaluate gross α and β^(-) radioactivities in natural water based on an online high-purity germanium detector gamma measurement system.The major gamma activities in natural water are provided by natural and artificial radionuclides such as ^(40) K,^(137)Cs,and radionuclides belonging to ^(238)U and ^(232)Th series.The main a emitters related to gamma emissions in natural water are ^(224)Ra(240.98 keV)and ^(226)Ra(186.21 keV),and the β^(-) emitters are ^(40) K(1460.85 keV),^(214)Bi(609.31 keV),^(208)Tl(583.19 keV),and ^(214)Pb(351.93 keV).The formula for gross α and β^(-) activity concentration is based on these radionuclides,and the short half-life decay products are considered in the calculation.The detection efficiency of the device across energy region(0–3 MeV)is obtained through Monte Carlo simulation,and a calibration experiment is conducted to verify the simulation results.Gamma radioactivity is measured continuously for 114 d in Pixian County and Dongfeng Canal located in the Zouma River,Chengdu,Sichuan Province,China.A comparison of the calculation results and monitoring data from the Sichuan Management and Monitoring Center Station of Radioactive Environment indicates that the percentage and absolute error of a activity concentration is lower than 53%and 0.02 Bq/L,respectively,and that of β-activity concentration is lower than 33.2%and 0.016 Bq/L,respectively.The method can rapidly determine gross α and β^(-) activity concentrations in natural water online.
基金supported by the National Natural Science Foundation of China(No.41374136)
文摘Based on the geochemical prospecting data, we have calculated the gamma absorbed dose rates in air 1 m above the ground surface in the Chengdu Plain, analyzed the relationship between the geological conditions and the distribution of the natural radionuclides, and preliminarily studied the influence of the geological conditions on the terrestrial radiation level in the Chengdu Plain. The result shows that the terrestrial radiation level in the Chengdu Plain is slightly lower than the average values of China and varies greatly according to the complex geological conditions.
基金supported by the National Natural Science Foundation of China(Nos.12005025,41774190).
文摘To perform an integral simulation of a pool-type reactor using CFD code,a multi-physics coupled code MPC-LBE for an LBE-cooled reactor was proposed by integrating a point kinetics model and a fuel pin heat transfer model into self-developed CFD code.For code verification,a code-to-code comparison was employed to validate the CFD code.Furthermore,a typical BT transient benchmark on the LBE-cooled XADS reactor was selected for verification in terms of the integral or system performance.Based on the verification results,it was demonstrated that the MPC-LBE coupled code can perform thermal-hydraulics or safety analyses for analysis for processes involved in LBE-cooled pool-type reactors.
基金supported by the National Key R&D Project of China(No.2017YFC0602100)the National Natural Science Foundation of China(No.41774147)Sichuan Science and Technology Support Program(No.2015GZ0272)
文摘The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectrum evaluation method is able to obtain the background-corrected and interference-free net peaks, which is significant for quantization analyses. A variety of analytical parameters and functions to describe the features of the fluorescence spectra of pure elements are used and established, such as the mass absorption coefficient, the Gi factor, and fundamental fluorescence formulas. The FSLS iterative program was compiled in the C language. The content of each component should reach the convergence criterion at the end of the calculations. After a basic theory analysis and experimental preparation, 13 national standard soil samples were detected using a spectrometer to test the feasibility of using the algorithm. The results show that the calculated contents of Ti, Fe, Ni, Cu, and Zn have the same changing tendency as the corresponding standard content in the 13 reference samples. Accuracies of 0.35% and 14.03% are obtained, respectively, for Fe and Ti, whose standard concentrations are 8.82% and 0.578%, respectively. However, the calculated results of trace elements (only tens of lg/g) deviate from the standard values. This may be because of measurement accuracy and mutual effects between the elements.
基金supported by the National Natural Science Foundation of China(Nos.41474159 and 41504139)Sichuan Youth Science and Technology Foundation(No.2015JQ0035)+1 种基金Sichuan Science and Technology Support Program(No.2017GZ0390)the Key Laboratory of Applied Nuclear Techniques in Geosciences Sichuan(No.gnzds2014006)
文摘Pulse shaping,which improves signal-to-noise ratio excellently,has been extensively used in nuclear signal processing.This paper presents a cusp-like pulse-shaping technique developed through the recursive difference equation in time domain.It can be implemented in field programmable gate array hardware system.Another flat-topped cusp-like shaper is developed to optimize the time constant of pulse shaping and reduce the influence of ballistic deficit.The methods of both baseline restoration and pile-up rejection are described.The ^(137)Cs energy spectra measured with the digital cusp-like shaper are 6.6% energy resolution,while those by traditional analog pulse shaper are 7.2% energy resolution,under the same conditions.This technique offers flexibility,too,in adjusting the pulse shaper parameters.
文摘The rapid identification of radioactive substances in public areas is crucial.However,traditional nuclide identification methods only consider information regarding the full energy peaks of the gamma-ray spectrum and require long recording times,which lead to long response times.In this paper,a novel identification method using the event mode sequence(EMS)information of target radionuclides is proposed.The EMS of a target radionuclide and natural background radiation were established as two different probabilistic models and a decision function based on Bayesian inference and sequential testing was constructed.The proposed detection scheme individually processes each photon.When a photon is detected and accepted,the corresponding posterior probability distribution parameters are estimated using Bayesian inference and the decision function is updated.Then,value of the decision function is compared to preset detection thresholds to obtain a detection result.Experiments on different target radionuclides(137Cs and 60Co)were performed.The count rates of the regions of interest(ROI)in the backgrounds between[651,671],[1154,1186],and[1310,1350]keV were 2.35,5.14,and 0.57 CPS,respectively.The experimental results demonstrate that the average detection time was 6.0 s for 60Co(with an activity of 80400 Bq)at a distance of 60 cm from the detector.The average detection time was 7 s for 137Cs(with an activity of 131000 Bq)at a distance of 90 cm from the detector.The results demonstrate that the proposed method can detect radioactive substances with low activity.
基金supported by the National Natural Science Foundation of China(No.12105029)。
文摘Currently,the liquid scintillation method is widely used to measure the activity of tritiated water in the primary circuit of nuclear power plants,which leads to the continuous production of radioactive waste during measurement.In addition,the real-time activity information of tritiated water cannot be obtained.To solve this problem,herein we present an online tritiated water measurement method based on plastic scintillators that used the optical transport process in the Geant 4 software toolkit to build a model of plastic scintillation detection for tritiated water.Through simulation,the basic geometric dimensions of the detector were determined.In this dimension,using one detector to measure for 3 h,when the tritiated water activity was 100 Bq/L,its resolution was 16%(16 Bq/L).In addition,calculations were performed for the presence of other background signals to obtain the minimum detectable concentration.
文摘Correction to:NUCL SCI TECH(2021)32:143 https://doi.org/10.1007/s41365-021-00982-z In the original article,the funding information were missing and in this correction the funding information is given below:Funding This work was supported by the National Natural science Foundation of China(No.41774190),the Special-funded program on national key scientific instruments and equipment development(No.2017YFC0602105),and the Department of Science and Technology of Sichuan Province(No.2020JDRC0109).
基金This work was supported by the Sichuan Science and Technology Program(No.2020JDRC0108)the National Science Foundation of China(Nos.41774147 and 41774190).
文摘In this study,the theory of minimum detectable activity concentration(MDAC)for airborne gamma-ray spectrometry(AGS)was derived,and the relationship between the MDAC and the intrinsic effi-ciency of a scintillation counter,volume,and energy res-olution of scintillation crystals,and flight altitude of an aircraft was investigated.To verify this theory,experi-mental devices based on NaI and CeBr 3 scintillation counters were prepared,and the potassium,uranium,and thorium contents in calibration pads obtained via the stripping ratio method and theory were compared.The MDACs of AGS under different conditions were calculated and analyzed using the proposed theory and the Monte Carlo method.The relative errors found via a comparison of the experimental and theoretical results were less than 4%.The theory of MDAC can guide the work of AGS in probing areas with low radioactivity.
基金supported by the Natural Science Foundation of China(NSFC)(No.41474159)National High-tech R&D Program of China(863 Program)(Nos.2012AA061803 and 2014AA093403)Open Foundation of Applied Nuclear Techniques in Geosciences Key Laboratory of Sichuan Province(No.gnzds2014006)
文摘Due to variable time for charge collection,energy resolution of nuclear detectors declines,especially compound semiconductor detectors like cadmium zinc telluride(CdZnTe) detector.To solve this problem,an analog rise-time discriminator based on charge comparison principle is designed.The reference charge signal after attenuation is compared with the deconvoluted and delayed current signal.It is found that the amplitude of delayed current signal is higher than that of the reference charge signal when rise time of the input signal is shorter than the discrimination time,thus generating gating signal and triggering DMCA(digital multi-channel analyzer) to receive the total integral charge signal.When rise time of the input signal is longer than discrimination time,DMCA remains inactivated and the corresponding total integral charge signal is abandoned.Test results show that combination of the designed rise-time discriminator and DMCA can reduce hole tailing of CdZnTe detector significantly.Energy resolution of the system is 0.98%@662 keV,and it is still excellent under high counting rates.