期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Phase Structure Change of Mo-Si System duringMechanical Alloying 被引量:1
1
作者 liu, sj Qu, XH +1 位作者 liu, ZJ Huang, BY 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 1999年第5期423-426,共4页
The structure of Mo-15.16 Si, Mo-30 Si and Mo-36.3 Si (wt pct) elemental powder mixture during mechanical alloying was studied using electron microscopy and X-ray diffraction. It had been found that, in all the system... The structure of Mo-15.16 Si, Mo-30 Si and Mo-36.3 Si (wt pct) elemental powder mixture during mechanical alloying was studied using electron microscopy and X-ray diffraction. It had been found that, in all the systems under study, silicon disappeared initially during mechanical alloying (MA). In the Mo-Si systems all products were in form of amorphous state after long time milling, but there were different intermediate products. MoSi2 and Mo5Si3 intermetallic compounds in the Mo-30Si and Mo-36.3Si (wt pct) were directly synthesized from elements through inter-diffussion process. The high density of defects and interface of nano-crystal lines induced by ball milling would promote the reaction process. Only in the Mo-15.16Si (wt pct) system was Mo(Si) supersaturated solid solution formed as an intermediate product. Schematic free-energy diagram of Mo-Si system based on the thermodynamics was used to analyze the difference among the intermediate state products. 展开更多
下载PDF
GAS FLOW INJECTION DETERMINATION OF NITROGEN DIOXIDE USING GALVANIC COULOMETRIC DETECTOR
2
作者 liu, sj Shen, HX +1 位作者 Ding, XC Feng, JX 《Chinese Chemical Letters》 SCIE CAS CSCD 1995年第11期975-978,共4页
The direct determination of NO2 gas using a galvanic coulometric cell as detector by gas flow injection analysis (FIA) is described. The simple modification of the flow injection allows the linear range for the determ... The direct determination of NO2 gas using a galvanic coulometric cell as detector by gas flow injection analysis (FIA) is described. The simple modification of the flow injection allows the linear range for the determination of NO2 gas from 0. 01 - 2 ppm(v/v)to be expanded to 8- 500 ppm (v/v) with a relative standard deviation of 3 - 4% (n=12) at a rate of 25 samples per hour and avoids the problem of bine consuming in the equilibrium performance. 展开更多
下载PDF
EFFECTS OF GAS FLOW RATE ON CLARK-TYPE OXYGEN GAS SENSOR
3
作者 liu, sj Shen, HX +2 位作者 Qiu, YH Wang, H Feng, JX 《Chinese Chemical Letters》 SCIE CAS CSCD 1995年第6期505-508,共4页
The flow rate sensitivity of membrane-covered oxygen gas sensor has been tested experimentally. the oxygen sensor,gas flowmeter,and air pump are arranged in six types of connective modes, the flow sensitivity of oxyge... The flow rate sensitivity of membrane-covered oxygen gas sensor has been tested experimentally. the oxygen sensor,gas flowmeter,and air pump are arranged in six types of connective modes, the flow sensitivity of oxygen sensor is notably different. Preliminary results on the positional flow rate sensitivity of oxygen gas sensor are reported. 展开更多
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部